Flextool FP212G Скачать руководство пользователя страница 6

FLEXTOOL OPERATING INSTRUCTIONS

FLEXTOOL SUBMERSIBLE PUMPS

6

1300 353 986  

flextool.com.au

FLEXTOOL OPERATING INSTRUCTIONS

SUBMERSIBLE PUMPS

6

1300 353 986

flextool.com.au

TROUBLESHOOTING

SYMPTOM

POSSIBLE CAUSES AND CORRECTION

The drive motor is 

operating but the pump 

is not functioning.

Check that the coupling is fully inserted in the bell housing and secured by the trigger.
Check that the impeller is not obstructed.
Check that a kink in the discharge hose has not created an air lock preventing water from initially 

entering the pump.
Check that the pump is sufficiently submerged to allow water to cover the impeller.
Check that electric motor rotation is as shown by the direction arrow on the bell housing (anti-clockwise 

when viewing its drive dog).
Check that the threaded core ends on the flexible drive core have not unscrewed from the pump or 

coupling spindle due to reverse rotation of the motor.
Check that the inner flexible core has not failed.

There is a tendency 

for the pump head to 

bury itself in the heavy 

sediment

Overcome this by improvising an auxiliary strainer. Remove the top from an empty 20 litre drum and 

punch openings around the sides. Place the pump head in the drum below the water.

Model

Flexshaft  

Length  

m (ft)

Operating  

Weight  

kg (lb)

Shaft  

Core Diameter 

mm (in)

Shaft Casing  

Diameter  

mm (in)

Discharge 

Diameter  

mm (in)

Max  

Discharge Head  

m (ft)

Max  

Discharge  

l/h (gal/h)

Solids  

Capacity  

mm (in)

Product Code  

Australia

FP212G-6

6  

(19.7)

26.5  

(58.4)

13  

(0.5)

32  

(1.3)

50  
(2)

26  

(85.3)

63,000  

(16,642)

28  

(1.1)

FT201801-UNIT

FP212G-9

9  

(29.5)

38  

(83.8)

13  

(0.5)

32  

(1.3)

50  
(2)

26  

(85.3)

63,000  

(16,642)

28  

(1.1)

FT201803-UNIT

Model

Flexshaft  

Length  

m (ft)

Operating  

Weight  

kg (lb)

Shaft  

Core Diameter 

mm (in)

Shaft Casing  

Diameter  

mm (in)

Discharge 

Diameter  

mm (in)

Max  

Discharge Head  

m (ft)

Max  

Discharge  

l/h (gal/h)

Solids  

Capacity  

mm (in)

Product Code  

Australia

FP212A-6

6  

(19.7)

34  

(75)

15  

(0.6)

38  

(1.5)

50  
(2)

26  

(85.3)

63,000 

(16,642)

28  

(1.1)

FT201805-UNIT

FP212A-9

9  

(29.5)

42.5  

(93.7)

15  

(0.6)

38  

(1.5)

50  
(2)

26  

(85.3)

63,000 

(16,642)

28  

(1.1)

FT201818-UNIT

GENERAL PURPOSE PUMPS

ABRASION RESISTANT PUMPS

Model

Flexshaft  

Length  

m (ft)

Operating  

Weight  

kg (lb)

Shaft  

Core Diameter 

mm (in)

Shaft Casing  

Diameter  

mm (in)

Discharge 

Diameter  

mm (in)

Max  

Discharge Head  

m (ft)

Max  

Discharge  

l/h (gal/h)

Solids  

Capacity  

mm (in)

Product Code  

Australia

FP212C-6

6  

(19.7)

37.5  

(82.7)

15  

(0.6)

38  

(1.5)

50  
(2)

26  

(85.3)

63,000 

(16,642)

28  

(1.1)

FT201817-UNIT

CHEMICAL RESISTANT PUMPS*

*Improved chemical resistance to a wide range of chemicals compared to general purpose pumps.

Содержание FP212G

Страница 1: ...FOR MORE INFORMATION CONTACT US ON 1300 353 986 OR VISIT flextool com au Version 2 0 October 2022 OPERATING INSTRUCTIONS FLEXTOOL SUBMERSIBLE PUMPS FP212G FP212A FP212C...

Страница 2: ...itations potential hazards how it operates and how it stops torque from the drive unit to the pump head Submersible operation of the pump head ensures that it is self priming and does not require suct...

Страница 3: ...to the power unit so that it takes the weight of the pump off the exshaft Drive units should be operated on a level surface If the surface is not level the drive unit should be restrained to ensure th...

Страница 4: ...removed check the spindle bearings for slackness and smooth rotation SPECIFICATIONS General Purpose Model P212G 2 900 r min Maximum head 16 5 m Maximum discharge 63 000 litre h 3 700 r min Maximum hea...

Страница 5: ...g and plate for wear and corrosion Housing seals and seal sleeve for wear Adaptor seals and spindle seal diameter for wear Bearings for wear Strainer for missing grille segments Note Because the pump...

Страница 6: ...es Place the pump head in the drum below the water Model Flexshaft Length m ft Operating Weight kg lb Shaft Core Diameter mm in Shaft Casing Diameter mm in Discharge Diameter mm in Max Discharge Head...

Страница 7: ...tion information assistance or service provided by us is provided without liability or responsibility PROVIDED THAT the foregoing shall not exclude limit restrict or modify the right entitlements and...

Отзывы: