any damage to the battery box if foreign objects are deliberately or 

accidentally inserted into the battery box enclosure.   

 

The battery will discharge naturally if the system is unused for a period of 

time. 

 

It should be recharged every 2-3 months if unused. If this is not done, 

then the warranty will be null and void.    During normal operation, the 

batteries will be automatically remained in charged condition.   

 

Servicing of batteries should be performed or supervised by qualified 

personnel and with required precautions.   

 

When replacing batteries, it is necessary to replace ALL batteries with the 

same quantity, type & capacity. 

 

CAUTION – Do not dispose of batteries into a fire. The battery may 

explode. 

 

CAUTION – Do not open or damage the batteries. The electrolyte from 

the batteries is toxic and harmful to the skin and eyes.   

 

CAUTION – Risk of Electric Shock –Hazardous voltage may exist between 

battery terminals and ground. Test before touching with bare hands. 

 

CAUTION – A battery can present a risk of electrical shock and short 

circuit current.    The following precaution should be observed when 
working on batteries: 

1.

 

Remove watches, rings, or other metal objects. 

2.

 

Use tools with insulated handles. 

3.

 

Wear rubber gloves and boots. 

4.

 

Do not lay tools or metal parts on top of batteries. 

5.

 

Disconnect mains prior to connecting or disconnecting battery 
terminals. 

 

Do not plug or unplug the battery connector if UPS works in DC 
(discharging) mode. 

 

2.

 

Installation and Setup 

NOTE: Before installation, please inspect the unit. Be sure that nothing inside 

the package is damaged. Please keep the original package in a safe place for 

future use. 

 

2-1 Rear Panel View 

 

 

1.

 

DC connector : connects to either UPS or 2

nd

 battery box 

2.

 

DC breaker: Battery over-current protection breaker 