6 Mounting
FLUXUS H721
6.2 Transducers
41
UMFLUXUS_H721V1-5EN, 2022-05-15
Step 4: Fixation of the rail to the pipe
• Place the tension strap clamp (2) in the rail (see Fig. 6.23). Observe the orientation of the tension strap clamp.
• Slightly tighten the nut of the tension strap clamp (2).
• Screw the rail to tension strap clamp (1) (see Fig. 6.24).
• Tighten the nut of tension strap clamp (1), but not too firmly in order not to damage the tension strap.
Fig. 6.21:
Tension strap with metal spring and clamp
1 – metal spring
2 – tension strap clamp
Fig. 6.22:
Ratchet clasp with tension strap
1 – sense of rotation
2 – edge
3 – lever
4 – clasp screw with slot
Fig. 6.23:
Rail with tension strap clamp
1 – nut
2 – tension strap clamp
Fig. 6.24:
Rail, fixed on one side to the pipe
1 – tension strap clamp
2 – tension strap clamp
3 – nut