8 Installation of FLUXUS ADM 8127B
FLUXUS ADM 8027, F801, ADM 8127B
UMFLUXUS_F8V4-6-1EN, 2018-10-10
51
It is recommended to run the cables from the measuring point to the transmitter before connecting the transducers to
avoid load on the connectors.
• Remove the cable gland for mines M16 for the connection of the transducers (see Fig. 8.2).
• Open the cable gland for mines (see Fig. 8.4).
• Prepare the transducer cable if necessary.
• Remove as little of the insulation as possible when stripping the cable. After the connection has been established, the in-
sulation has to cover the lead up to the terminal.
• Push the end of the transducer cable with the stripped leads through the hose flange (2), screwed socket (5), compres-
sion rings (6), sealing ring (7) and gland body (8) into the housing (see Fig. 8.4).
• Push the hose flange (2) into the cable protection hose (1).
• Screw the gland body (8) into the housing.
• Fix the screwed socket (5) and the gland body (8) with the clamp by firmly tightening the screws of the clamp.
• Fix the cable protection hose (1) at the cable gland for mines with the hose clamp (4) by tightening the screws firmly (see
• Insert the cables via the beveled edges of the dividing wall into the not intrinsically safe area of the connection compart-
ment (see Fig. 8.5).
• Connect the leads to the terminals of the transmitter. The stripped twisted end of the external shield that is to be connect-
ed to the terminal has to be as short as possible (see Fig. 8.3, Fig. 8.5 and Tab. 8.1).
Fig. 8.4: Cable gland for mines M16
Attention!
Observe the "Safety Instructions for the Use in Explosive Atmosphere" (see document SIFLUXUS).
Fig. 8.5: Terminals for the connection of the transducer for mines
1
3
2
4
4
5
6
7
8
6
1
cable protection hose
2
hose flange
3
screw
4
hose clamp
cable gland for mines consisting of:
5
screwed socket with clamp
6
compression ring
7
sealing ring
8
gland body
cable gland for
mines
AR
2
Schirm
Schirm
3
13 14
AV
AV
S
ARS
PE
L-
L+
dividing wall with
beveled edges
not intrinsically
safe area
intrinsically safe
area
transducer for mines