LEO EL S | L BMS 

Содержание LEO EL L BMS

Страница 1: ...LEO EL S L BMS ...

Страница 2: ...s 6 5 Start Up and Operation 8 6 Service and warranty terms 10 7 Conformity with WEEE directive 2012 19 UE 12 1 APPLICATION LEO EL heaters make up a decentralised heating system Fan heaters are used for heating large volume buildings general industrial and public buildings etc The devices are designed for indoor use where maximum air dustiness does not exceed 0 3 g m3 2 ...

Страница 3: ... 8 59 0 79 2 69 6 57 2 Acoustic pressure level dB A 56 3 50 7 43 9 64 1 54 5 42 1 Horizontal range m 14 0 11 0 8 5 24 0 15 0 9 5 Vertical range m 5 3 4 3 3 4 8 3 5 5 3 5 Device mass kg 19 7 27 8 50 50 Max working temperature oC Acoustic power level according to EN ISO 3744 2011 Acoustic pressure level has been measured 5m from the unit in a 1500m3 space with a medium sound absorption coefficient V...

Страница 4: ... 12 5 11 8 6 10 7 1 7 8 8 3 10 1 11 1 11 9 20 17 15 20 6 8 7 6 8 0 9 8 10 8 11 4 29 26 24 1700 2800 4250 13 7 15 1 16 3 19 3 21 4 23 3 24 19 14 10 13 0 14 2 15 4 18 6 20 5 22 2 27 24 21 20 12 4 13 7 14 7 17 8 19 9 21 2 33 30 28 3rd step of heating 0 1700 2800 4250 18 0 20 3 22 8 26 0 29 2 33 3 29 24 18 10 17 2 19 6 21 2 24 5 28 0 31 0 36 30 26 20 16 6 19 1 20 6 24 0 27 5 30 1 44 38 34 2 TECHNICAL ...

Страница 5: ...age the minimal distances from the walls and ceiling have to be kept 2 U profiles should be mounted in corners as drawing shows Is not allowed to screw profiles in other places 2 3 3 U PROFILES optional U profiles should be mounted in corners as drawing shows Is not allowed to screw profiles in other places 3 1 INSTALLATION BRACKET 3 2 ASSEMBLY INSTRUCTIONS M8 screws are in set with bracket ...

Страница 6: ...c mode After reaching the temperature turning off the fans and heating elements NT Continuous mode After reaching the temperature turning off the heating elements and continuous operation of the fan K1 LEO EL L BMS K2 LEO EL S BMS Each time the device is switched off the heaters are being cooled for next 30 seconds Power supply LEO EL S BMS OMY 5x4 0 mm2 Circuit protection B20 LEO EL L BMS OMY 5x6...

Страница 7: ... connecting DRV modules to the T box controller or BMS you have to binary set addresses on each each DRV must have individual address DRV module by DIP switch SW1 To address modules check if the power supply is turned off than set then the addresses as shown in the table than turn on the power supply LEO EL L BMS OMY 5x6 0 mm2 Circuit protection B40 Power supply 3 x 400V 50Hz LEO EL S BMS OMY 5x4 ...

Страница 8: ... off immediately Never operate a failure unit The producer does not take any responsibility for damages caused by failure operation Switch off the electrical supply while servicing or cleaning Periodic inspections To keep proper technical parameters Flowair recommends periodic service every 6 months of fan heaters on behalf of the user During inspections user should Check heating elments if is it ...

Страница 9: ... 9 ...

Страница 10: ...s and its limitation In the case of any irregularities in the device operation please contact the manufacturer s service department The manufacturer bears no responsibility for operating the device in a manner inconsistent with its purpose by persons not authorised for this and for damage resulting from this ...

Страница 11: ... 11 ...

Страница 12: ...s natural resources reusing resources obtained from the processing of equipment Running a business without harming the environment and observing the rules of proper handling of waste electrical and electronic equipment is a priority for Flexiheat The symbol of the crossed out wheeled bin placed on the equipment packaging or documents attached means that the product must not be disposed of with oth...

Страница 13: ... 13 ...

Страница 14: ...xiheat Declaration Of Conformity were produced in accordance to the following Europeans Directives zijn geproduceerd in overeenstemming met de volgende 1 2014 30 UE Electromagnetic Compatibility EMC 2 2006 42 WE Machinery 3 2014 35 UE Low Voltage Electrical Equipment LVD 4 2009 125 WE Energy related products ErP 2015 and harmonized norms with above directives PN EN 60034 1 2011 Rotating electrical...

Страница 15: ...iency η s flow 93 3 95 6 Seasonal space heating energy efficiency η s h 35 7 36 6 Information relevant for disassembly recycling and or disposal at end of life isassembly should be carried out by a person with appropriate authorizations After disassembly waste should be segregated housing steel recyclable heating elments aluminum fan dispose of in accordance with the rules for the disposal of elec...

Страница 16: ...16 www flowair com 52383 MT DTR LEO EL S L EN PL NL RU V1 ...