![FlexGain SA-FOM4 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/flexgain/sa-fom4/sa-fom4_installation-and-operation-description_2304632017.webp)
SA
-FOM4 Installation Description
SA
-FOM4-2.0-20030102
5.5 Set E1 Channel to Out Of Service
Please enter a selection [0-9]: 2
Press
2
and the
Enter
Please enter Out_OF_Service Channel(s) No.: 2 4
and the numbers can be entered at any order.
Once the E1 channel(s)
channels 2 and 4 are set to Out of Service.
STATUS LOS MAJ MIN
IS
OOS
IS
OOS
IS
key under main menu. The following
prompt appears:
Enter the E1 Channel Number(s) that user wishes to set to
Out of Service status. Four channels can be set at one time
are set to Out Of Service, the
corresponding E1 LEDs go off.
A system report appears first shows the status of E1
SA
-FOM4 system report
E1LLB NELLB E1RLB E1RLBed
Channel_1
Channel_2
Channel_3
Channel_4
Optical_1