User Manual
LTU Orion 3
81
------------------------------------------------------------------------
The results of the command show the coded configuration of the device and can be copied from
the terminal window into the notepad as well as saved on any data carrier. This txt file can be
downloaded into a similar device with the help of the LOAD command via the XModem or 1K
XModem protocols.
4.6.4.24 <LOAD> Command
The <LOAD> command downloads the configuration file obtained with the help of the DUMP
command into a device via the XModem or 1K XModem protocols. For Windows 95 or above, this
procedure can be performed with the help of the HyperTerminal program. By typing LOAD, the
following text will be displayed in the terminal window:
CO_FMM>LOAD
Now upload configuration via XModem or 1K XModem
C
Select "Send File” in the Transfer menu. Select the protocol XModem or 1K XModem in the
window which appears. Select the downloading configuration file and click the Send button.
If downloading is successful, a message will appear to reset the modem:
Configuration was loaded successfully.
For all configuration options to apply, type RESET to reset modem.
If the configuration file contained errors, a message with the line number in which the error was
detected will be displayed. The configuration of the device in this case will not change.
4.6.4.25 <TLM> Command
The < TLM > command shows the external alarm status of Regenerators.
CO_01_FMM>TLM
Distant external alarms status
---------- Line 1 -------- Line 2 -------- Line 3 -------- Line 4 ----
| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3|
----------------------------------------------------------------------
RR01 | off off off | off off off | off off off | off off off |
RR02 | off off off | off off off | off off off | off off off |
RR03 | off off off | off off off | off off off | off off off |
RR04 | off off off | off off off | off off off | off off off |
RR05 | off off off | off off off | off off off | off off off |
RR06 | off off off | off off off | off off off | off off off |
RR07 | off off off | off off off | off off off | off off off |
RR08 | off off off | off off off | off off off | off off off |
RR09 | off off off | off off off | off off off | off off off |
RR10 | off off off | off off off | off off off | off off off |
RR11 | off off off | off off off | off off off | off off off |
RR12 | off off off | off off off | off off off | off off off |
RR13 | off off off | off off off | off off off | off off off |
----------------------------------------------------------------------
CO_01_FMM>
Option: D
– shows the reaction of the external alarms of Regenerators.
CO_01_FMM>TLM D
Reactions on external alarms
---------- Line 1 -------- Line 2 -------- Line 3 -------- Line 4 ----
| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3|
----------------------------------------------------------------------
RR01 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR02 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR03 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR04 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR05 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR06 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR07 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR08 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |