This expansion tank and the entire system must be checked annually by a qualified professional.

Visually examine the tank and its connection to the system piping looking for any signs of water leakage or corrosion on the

exterior of the tank or the connection.

If this expansion tank shows any visible signs of leaking, corrosion or rusting, the tank must be replaced

immediately to avoid personal injury or property damage. Do not adjust the tank air pressure if there

are any signs of corrosion on the tank. Failure to follow these instructions may result in serious injury or death and or 

property damage.



D I ME N S I ON S  &  C A P A C I T I E S

Rev. 6.18

          

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



 



Visually inspect the product for any signs of damage that may have occurred during transportation.  If the tank is dented, bent

 

or scratched, return the product to the original purchase point for replacement.





 



This expansion tank is shipped from the factory with a pre-charge of 12 psi.  Any adjustments to the factory pre-charge 

must be done prior to initial tank installation and with 0 psi pressure on the system. DO NOT ADJUST THE PRE-CHARGE

 

OF THE EXPANSION TANK WITH THE SYSTEM UNDER PRESSURE!

The expansion tank should be pre-charged to 

match the boiler fill valve setting.

 

failure to  properly adjust the pre-charge will shorten the life expectancy of the product.

 



 



 



Remove the protective cap from the air valve.   
Check the tank pre-charge pressure using a standard tire pressure gauge.
If required add air to the tank using a manual bicycle tire pump until the proper pre-charge pressure is reached.
Replace the protective cap on the air valve.



T Y P I C A L   I N S T A L L A T I O N S

P.O.

Inlet

To 
System

In Line
Expansion

Pressure

Relief 

Valve

Auto Fill 

Valve

Air

Separator

Flow

Check

Air

Vent

P.O.

Vertical
Floor 
Mount 
Expansion 
Tank

Inlet

To 
System

Pressure

Relief 

Valve

Auto Fill 

Valve

Air

Separator

Flow

Check

Air

Vent

S X H T  
S E R I E S

H T X  
S E R I E S

M

ATERIALS

 

OF 

C

ONSTRUCTION

Tank: 16-gauge, cold rolled steel

Finish: Appliance quality paint for corrosion resistance

Water Chamber SXHT: Top diaphragm is 100 % butyl rubber, lower
water chamber is copolymer polypropylene

Diaphragm Material HTX: 100% butyl rubber

Connection: Welded steel

Testing: High pressure, seam weld, helium, final pre-charge check

Air Valve: Brass valve with o-ring seal

Warranty:

5 years

Boiler 

Output 

1000’s 

BTUH 

Copper 

Baseboard 

& Radiant 

Type of Radiation 

Convectors & Unit           Cast Iron

Cast Iron 

        Heaters

   Radiators                      Baseboard 

25 

HTX 15 

HTX 15 

HTX 15 

HTX 15 

50 

HTX 15 

HTX 30 

HTX 30 

HTX 30 

75 

HTX 30 

HTX 30 

HTX 60 

HTX 60 

100 

HTX 30 

HTX 30 

HTX 60 

HTX 60 

125 

HTX 30 

HTX 60 

HTX 60 

HTX 60 

150 

HTX 30 

HTX 60 

HTX 90 

HTX 90 

175 

HTX 60 

HTX 60 

HTX 90 

HTX 90 

200 

HTX 60 

HTX 60 

HTX 90 

HTX 90 

250 

SXHT 30 

SXHT 30 

SXHT 40 

SXHT 30 

300 

SXHT 30 

SXHT 40 

SXHT 40 

SXHT 30 

350 

SXHT 30 

SXHT 40 

SXHT 60 

SXHT 40 

400 

SXHT 30 

SXHT 60 

SXHT 90 

SXHT 40 

500 

SXHT 40 

SXHT 60 

SXHT 90 

SXHT 40 

600 

SXHT 40 

SXHT 90 

SXHT 90 

SXHT 60 

700 

SXHT 60 

SXHT 90 

SXHT 90 

SXHT 60 

800 

SXHT 60 

SXHT 110  

SXHT 110 

SXHT 90 

900 

SXHT 60 

SXHT 110 

SXHT 110 

SXHT 90 

1000 

SXHT 90 

SXHT 110 

SXHT 110 

SXHT 90 

1.

Drain boiler system or isolate the area where expansion

tank will be installed.

2.

Install expansion tank on supply side of the boiler, on

the suction side of the circulator. Adequate thread sealant
(pipe dope) must be added to ensure a leak free
installation.

3.

Connect system piping to discharge opening of the tank

using a tee, air scoop, or other suitable tapping in the
system.

4.

Pressurize the system and check for leaks.

5.

Restart the boiler system.

The tank 

(HTX) is designed to be supported by system piping. Make 

sure that there is adequate means of supporting the system piping 

and, if necessary, add strapping, brackets, or pipe hangars. 

DO NOT INSTALL THIS EXPANSION TANK IN THE HORIZONTAL 

POSITION.

Maximum working pressure 100 psig. Maximum working temperature, 240 F. Tank pre-charge 12 psig.

Note: HTX series expansion tanks ARE NOT suitable for potable water and are only to be used on closed systems. 

Model 

Capacity 

(gallons) 

Acceptance 

Volume 

(@12/30 PSIG) 

Max. 

Acceptance 

Volume 

Dimensions 

(inches) 

Weight 

(lbs) 

Connection 

Size 

(C) 

Diameter 

(B) 

Height 

(A) 

HTX 15 

2.1

.85

1.0

½” MPT

8

11.6

6

HTX 30 

4.8

1.9

2.4

½” MPT

11

14.5

10

HTX 60 

6.0

2.9

3.6

½” MPT

11.4

17.6

11

HTX 90 

15.0

6.0

6.0

¾” MPT

16

20.8

28

SXHT 30

15.0

6.0

6.0

1” FPT

16

21.7

32

SXHT 40

20.0

8.0

8.0

1” FPT

16

28.8

39

SXHT 60

33.0

13.3

13.3

1” FPT

16

42.8

57

SXHT 90

44.0

17.7

17.7

1 ¼” FPT

21

36.2

72

SXHT 110

62.0

24.9

24.9

1 ¼” FPT

21

47.9

112

SXHT 160

81.0

32.6

32.6

1 ¼” FPT

21

62.0

123

QUICK SIZING CHART