![Fleem SRE 3010 NF Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/fleem/sre-3010-nf/sre-3010-nf_operating-manual_2303504033.webp)
E- 0
No flame during ignition
GB
33
E- 1
Flame sensor failure.
Check fuel, restart the heater. Read chapter Q point
5. Use correct fuel (see chapter “The right fuel”).
Check fuel, restart the heater. Read chapter Q point
5. Use correct fuel (see chapter “The right fuel”).
Check fuel, restart the heater. Read chapter Q point
5. Use correct fuel (see chapter “The right fuel”).
Check fuel, ventilate the room. Restart the heater.
Read chapter Q point 5. Use correct fuel (see chap-
ter “The right fuel”).
Disconnected the mains plug and restart.
Cool down, disconnect the mains plug and restart.
Disconnect the mains plug and restart.
Avoid shocks. The heater must be levelled.
Ventilate the room and restart the heater
Ventilate the room and restart the heater
Push the button KEY LOCK 3 times to unlock the
heater.
Refill the removable tank. Check if the fuel filter
contains water.
Push the - and + buttons to adjust the time.
Push the - and + buttons to adjust the set time when
the heater has to start.
E- 2
No flame after ignition.
E- 4
Poor flame during normal
burning.
E- 5
Ignition temperature too low.
E- 6
Ignition temperature too high.
E- 7
Wrong blower speed.
E- 9
Tilt switch.
E- A
Room temperature > 35°C
E- H
Electronics temperature > 60°C
KL
KEY LOCK.
FUEL
Out of fuel.
TIMER
The heater shows the set
time for timer.
48
Hr
The heater has been operating Switch the heater on again
continuously for a period of 48
hours and has switched itself
off (refer to chapter K).
E- 11
Too little fresh air
Ventilate
TIME
The heater shows the actual time.
CODE CAUSES
WHAT TO DO
Always contact your dealer for any malfunctioning not listed above and/or when the
error keeps occuring after taking the corrective measure as described above.
Manual.indd 33