Troubleshooting
Problem
Cause
Correction
1. Water conditioner fails to
regenerate.
A. Electrical service to unit has
been interrupted
A. Assure permanent electrical service
(check fuse, plug, pull chain, or switch)
B. Timer is defective.
B. Replace timer.
C. Power failure.
C. Reset time of day.
2. Hard water.
A. By-pass valve is open.
A. Close by-pass valve.
B. No salt is in brine tank.
B. Add salt to brine tank and maintain
salt level above water level.
C. Injector screen plugged.
C. Clean injector screen.
D. Insufficient water flowing into
brine tank.
D. Check brine tank fill time and clean
brine line flow control if plugged.
E. Hot water tank hardness.
E. Repeated flushings of the hot water
tank is required.
F. Leak at distributor tube.
F. Make sure distributor tube is not
cracked. Check O-ring and tube pilot.
G. Internal valve leak.
G. Replace seals and spacers and/or
piston.
3. Unit used too much salt.
A. Improper salt setting.
A. Check salt usage and salt setting.
B. Excessive water in brine tank.
B. See problem 7.
4. Loss of water pressure.
A. Iron buildup in line to water
conditioner.
A. Clean line to water conditioner.
B. Iron buildup in water condi-
tioner.
B. Clean control and add mineral cleaner
to mineral bed. Increase frequency of
regeneration.
C. Inlet of control plugged due
to foreign material broken loose
from pipes by recent work done on
plumbing system.
C. Remove piston and clean control.
5. Loss of mineral through drain
line.
A. Air in water system.
A. Assure that well system has proper
air eliminator control. Check for dry well
condition.
B. Improperly sized drain line flow
control.
B. Check for proper drain rate.
6. Iron in conditioned water.
A. Fouled mineral bed.
A. Check backwash, brine draw, and
brine tank fill. Increase frequency of re-
generation. Increase backwash time.
7. Excessive water in brine
tank.
A. Plugged drain line flow control.
A. Clean flow control.
B. Plugged injector system.
B. Clean injector and screen.
C. Timer not cycling.
C. Replace timer.
D. Foreign material in brine valve.
D. Replace brine valve seat and clean
valve.
E. Foreign material in brine line
flow control.
E. Clean brine line flow control.
Содержание 2900S
Страница 1: ...Model 2900s Service Manual IMPORTANT Fill in Pertinent Information on Page 3 for Future Reference...
Страница 19: ...Page 19 Notes...
Страница 23: ...Page 23 Notes...
Страница 29: ...Page 29 Notes...
Страница 30: ...Page 30 1700 Brine System Assembly For Service Assembly Numbers See the Back of this Manual 60034_REVB...
Страница 46: ...Page 46 Flow Data Injector Draw Rates Downflow TR22089 2900s Valve 1600 Series Injector Draw Rates...
Страница 52: ...Page 52 Environmental Backplate Dimensions 61500 2900LNE_REVB...
Страница 53: ...Page 53 Designer Backplate Dimensions 61500 2900LNE_REVB...
Страница 56: ...Page 56 Wiring Diagrams System 4 Single Valve Regeneration Immediate and Delayed Valve Wiring 18684_REVD...
Страница 57: ...Page 57 Wiring Diagrams System 4 With Remote Signal Start Valve Wiring 15405_REVF...
Страница 58: ...Page 58 Wiring Diagrams System 5 Interlocked Regeneration Valve Wiring 18685 01_REVD 18685 02_REVD...
Страница 59: ...Page 59 Wiring Diagrams 18686 01_REVE 18686 02_REVE System 6 Series Regeneration Valve Wiring...
Страница 60: ...Page 60 Wiring Diagrams System 7 Alternating Regeneration Valve Wiring 18687 01_REVE 18687 02_REVE...
Страница 61: ...Page 61 Wiring Diagrams 16172_REVG System 7 Alternating Regeneration Valve Wiring...
Страница 64: ...P N 41689 Rev B 5 1 08...