Flavor Burst CTP BASE BEV-1S Скачать руководство пользователя страница 11

 

10

 

Cabinet   

(Continued)

 

 

ITEM 

PART NO. 

DESCRIPTION 

QTY. 

FUNCTION 

 

20-1 SYR 307 

PERISTALTIC SYRUP PUMP – 
SOFT SERVE 

8* 

0** 

FOR “SS” & “BLD” SYSTEMS:

 Pumps 

syrup from flavor bags into flavor  
lines. 
*8 for SS-1S & BLD-1S systems.  
**0 for BEV-1S & CBB-1S systems. 

           OR…

 

20-2 SYR 926 

PERISTALTIC SYRUP PUMP - 
BEVERAGE 

8* 

0** 

FOR “BEV” SYSTEMS:

 Pumps syrup from 

flavor bags to flavor lines. 
*8 for BEV-1S systems.  
**0 for SS-1S, BLD-1S & CBB-1S systems. 

           OR…

 

20-3 SYR 926P 

PERISTALTIC SYRUP PUMP – 
PREMIUM BEVERAGE 

8* 

0** 

FOR “CBB” SYSTEMS:

 Pumps syrup from 

flavor bags to flavor lines. 
*8 for CBB-1S systems.  
**0 for SS-1S, BLD-1S & BEV-1S systems. 

21  CAB 155L 

PUMP MOUNTING STRIP 

Support for syrup trays and spacing 
between panels. 

22  CAB 155R 

PUMP MOUNTING STRIP 

 Support for syrup trays and spacing  
between panels. 

23  FAS 2037 

TAPPED NYLON SPACER 

12 

Secures screw to center panel, and  
support for trays. 

24  FAS 2032 

STANDARD NYLON SPACERS 

12  Provides extra support for flavor trays. 

25  FAS 2034 

8-32 X 3/4" MACHINE SCREW 

12  Attaches bushings to divider panel. 

26  MIS 3067 

OPEN/CLOSED BUSHING 

Strain relief for internal 9-Tube  
Assembly. 

27 FIX 

1033 

1/4" X 1/4" BLKHD (PUSH-TO-
CONNECT) 

Connects Sanitizer Tank tube to the unit. 

28  TUB 803 

TUBING-PER FOOT 

Transports sanitizer solution from tank to 
pump. 

29  CAB 133 

BASE PANEL 

Attaches the bottom of the inner and side 
panels. 

30  RUB 618 

RUBBER BUMPER WITH WASHER 

Provides spacing between cabinet base and 
table. 

31  FAS 2035 

8-32 NUTS - EXT. LOCK WASHER 

Attaches to screw and holds rubber bumper 
in place. 

32  MIS 3074 

SHORTY PLUG #1672 

Covers screw hole in rubber bumper. 

33  FAS 2040 

6-32 X 1/4" TAPPING SCREW 

24  Secures tray support bracket to side panels. 

34 

CAB 135L-A 

LEFT SIDE PANEL 

Holds tray support brackets and panel  
brackets. 

35  ELE 811 

RELAY  

Directs Touch Panel commands. 

36  TUB 803 

0.17 x 1/4 LDPE TUBING 

Transports sanitizer solution from tank  
to sanitizer pump. 

37  FIX 1053 

SANITIZER PUMP T CONNECTOR 

Connects the Base sanitizer line to the 
existing sanitizer tank. 

38  MIS 3191 

OPEN-CLOSE BUSHING 

FOR DLX & INT UNITS: 

Protects the 

sanitizer line entering the DLX / INT cabinet.

 

 

Содержание CTP BASE BEV-1S

Страница 1: ...port contact one of our qualified distributors PLEASE READ FIRST This supplement is not a full operations manual It does not contain complete information on installing and maintaining your new system...

Страница 2: ...1 PAGE INTENTIONALLY LEFT BLANK...

Страница 3: ...talling the Sanitizer Line External Tank 24 Installing the Sanitizer Line Internal Tank 25 Connecting the Pump Harness Cable 27 Connecting to a Standard Cabinet 27 Connecting to a Deluxe Cabinet 28 Co...

Страница 4: ...ause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the f...

Страница 5: ...ed daily to ensure the highest standard of sanitation When your equipment is delivered or if it has been unused for more than 24 hours follow the DAILY OPENING PROCEDURES in your standard operations m...

Страница 6: ...mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved NOTE Child...

Страница 7: ...6 PAGE INTENTIONALLY LEFT BLANK...

Страница 8: ...1 Transports sanitizer from tank to the pump 6 ELE 932 BASE PUMP SANITIZER CABLE HARNESS FOR BASE UNIT 1 Provides power to the syrup and sanitizer pumps 7 MIS 3191 OPEN CLOSE BUSHING 1 2 1 FOR DLX IN...

Страница 9: ...8 General System Overview Figure 1...

Страница 10: ...flush tube 9 1 MIS 3028 80 FLUSH TUBE ASSEMBLY SOFT SERVE 1 0 FOR SS BLD CBB SYSTEMS Connects with flavor line to flush with sanitizer solution 1 for SS 1S BLD 1S CBB 1S systems 0 for BEV 1S systems O...

Страница 11: ...4 MACHINE SCREW 12 Attaches bushings to divider panel 26 MIS 3067 OPEN CLOSED BUSHING 1 Strain relief for internal 9 Tube Assembly 27 FIX 1033 1 4 X 1 4 BLKHD PUSH TO CONNECT 1 Connects Sanitizer Tan...

Страница 12: ...11 PAGE INTENTIONALLY LEFT BLANK...

Страница 13: ...12 Cabinet Figure 2...

Страница 14: ...FAS 2040 6 32 x 1 4 PAN HEAD SCREW 1 ea Secures the Casing cover to the mounting brackets 2D FAS 2024 8 32 x 1 4 PAN HEAD SCREW 4 ea Secures the magnet assembly to the mounting brackets 2E FAS 2035 8...

Страница 15: ...14 Injector Blending Assembly and Related Parts Continued Figure 3A...

Страница 16: ...MP HOSE 1 4 1 ea Prevents pump tube from slipping 1E FAS 2051 ROLLED FLANGE EYELET 1 ea Creates tension for tighter fit 1F FIX 1036 1 4 TO 1 4 OD UNION ELBOW 1 ea Connects syrup in tube to pump 1G FIX...

Страница 17: ...16 Soft Serve Syrup Pump and Related Parts Figure 4A...

Страница 18: ...onnects pump to fitment 1D FIX 1035 1 4 TO 3 16 OD REDUCING UNION 1 ea Connects syrup pump to flavor line out 1E FIX 1036 1 4 TO 1 4 OD UNION ELBOW 1 ea Connects bag connector assembly to flavor line...

Страница 19: ...18 Beverage Syrup Pump and Related Parts Figure 4B...

Страница 20: ...UMP CLAMP HOSE 1 4 1 ea Prevents pump tube from slipping 1E FAS 2051 ROLLED FLANGE EYELET 1 ea Creates tension for tighter fit 1F FIX 1036 1 4 TO 1 4 OD UNION ELBOW 1 ea Connects syrup in tube to pump...

Страница 21: ...20 Soft Serve Syrup Pump and Related Parts Figure 4C...

Страница 22: ...s pump tube to reducing union 7 FIX 1053 SANITIZER PUMP T CONNECTOR 2 Splits the connection 8 TUB 803 0 17 x 1 4 LDPE TUBING 2 Transports sanitizer from the tank the pump 9 SYR 931 CLEAR TUBING 1 Tran...

Страница 23: ...22 Sanitizer Pump and Related Parts Figure 5...

Страница 24: ...3216 CLOSURE PLUG 5 8 2 Closes unused hole on panel 6 CAB 137 A ELECTRONICS COVER 1 Protects and covers the electronics microprocessor 7 FAS 2014 8 32 X 1 2 PAN HEAD 16 Secures various parts within t...

Страница 25: ...h system is installed on the same spout by using the double syrup port Injector Blending Head and an additional 9 Tube Assembly The basic installation and cleaning procedures can be found in the new O...

Страница 26: ...uxe or Integrated cabinet and locate the sanitizer pump It is the 9th pump on the bottom row to the far right 26390 NOTE TAKE CARE OF THE ELECTRICAL CONNECTIONS WHEN REMOVING THE BACK PANEL AND ELECTR...

Страница 27: ...LL A HOLE IN THE DELUXE CABINET BACK PANEL 1 ABOVE WHERE THE 9 TUBE ASSEMBLY PASSES THROUGH 26395 7 Insert the sanitizer line from the pump through the bushing 26396 8 Return the cabinet panel s to th...

Страница 28: ...r switch is in the off position with the end pressed in Or remove the power cord from the cabinet 26220 NOTE FAILURE TO TURN OFF THE CABINET COULD RESULT IN ELECTRICAL SHOCK Connecting to a Standard C...

Страница 29: ...the unused slotted hole of the plate 26375 4 Insert the Base unit s pump harness cable through the opening at the bottom of the Electronics Box and then through slotted hole of the plate 26376 5 Inse...

Страница 30: ...D WIRES WHEN REMOVING THE PLATE 3 Remove the plug from the unused slotted hole of the plate 26381 4 Insert the Base unit s pump harness cable through the Taylor cart panel s opening and then through s...

Страница 31: ...up Refer to your new Operations Manual to finish the rest of the setup and installation The new Operations Manual is also your guide to cleaning procedures and schedule refilling syrups daily operatin...

Страница 32: ..._______________________ 4 Maximum Fuse Size __________________________ Amps 5 Minimum Wire Ampacity _______________________ Amps Flavor Burst is a registered trademark of the Flavor Burst Company Tayl...

Отзывы: