(side view)

Connect the female spade connectors of the Rotor Cable 
D to the male connectors on the D Valve. 

16

Slide the bracket down and turn the side screws to brace 
the assembly against the freezer.

15

ADPT TY80S-FCB2   FCB Auto Draw Valve Conversion Kit

REV021313

pg. 4 of 6

Unlock and remove the coupler body of the 9-Tube 
Assembly, and then remove the sryup line manifold.  
Clean the duckbill check valve and the end of the 9-Tube 
Assembly if necessary.

20

Open the valve on the CO2 tank and check for any leaks 
in the connections.  Return the side panel to the freezer.

19

Ensure the CO2 tank is closed and then cut the supply 
line about 3” from the rear of the freezer.  Install the Tee 
with the C tube in the CO2 supply line. Use clamps to 
seal the connections.  

18

17

Insert the C tube through the hole with the black ring on 
the Cable Mounting Plate Assembly.  Connect the tube to 
the C Valve inside of the freezer. 