(side view)
Connect the female spade connectors of the Rotor Cable
D to the male connectors on the D Valve.
16
Slide the bracket down and turn the side screws to brace
the assembly against the freezer.
15
ADPT TY80S-FCB2 FCB Auto Draw Valve Conversion Kit
REV021313
pg. 4 of 6
Unlock and remove the coupler body of the 9-Tube
Assembly, and then remove the sryup line manifold.
Clean the duckbill check valve and the end of the 9-Tube
Assembly if necessary.
20
Open the valve on the CO2 tank and check for any leaks
in the connections. Return the side panel to the freezer.
19
Ensure the CO2 tank is closed and then cut the supply
line about 3” from the rear of the freezer. Install the Tee
with the C tube in the CO2 supply line. Use clamps to
seal the connections.
18
17
Insert the C tube through the hole with the black ring on
the Cable Mounting Plate Assembly. Connect the tube to
the C Valve inside of the freezer.