SECTION 2
INSTALLATION OF FIRE
2.1
UNPACKING THE FIRE
Carefully lift the fire out of the carton. Remove the loose item packaging carefully
from the front of the appliance. Check the contents as listed :-
Packing check list - manual control models
1 off
Fire box / burner assembly
1 off
Boxed ceramic base and 7 synthetic coals
1 off
Loose items bag inc guarantee card and cable fixing kit
1 off
Installation / user book (combined)
1 off
Efficiency baffle
1 off
Pebble set (if ordered as an optional extra) pack 2 of 2
1 off
Trim / Fret or Fascia (as applicable)
Packing check list - electronic flame control models
1 off
Fire box / burner assembly
1 off
Boxed ceramic base and 7 synthetic coals
1 off
Loose items bag inc guarantee card, restrictor baffle, grommet & cable fixing kit
1 off
Installation / user book (combined)
3 off
1.5V AA batteries (for control valve)
1 off
Trim
1 off
Fret & ashpan cover
1 off
Pebble set (if ordered as an optional extra) pack 2 of 2
2.2
INSTALLING THE FIRE BOX
Establish which type of flue you are intending to install the fire in to :-
225 x 225mm (9 inch x 9 inch) brick built chimneys
175mm (7 inch) diameter lined brick or stone flue, insulated pre-fabricated
metal flue box to BS 715 / BS EN 1856-2 or Pre-Cast Flue to BS EN 1858
When installing into 125mm (5 inch) diameter lined brick or stone flue, or
insulated pre-fabricated metal flue box to B.S. 715 and pre-cast flues the
restrictor baffle must not be fitted.
A spillage test must always be carried out to check satisfactory
clearance of flue products, regardless of the type of flue the
appliance is being fitted to.
11