Flavel Renoir FRECN0EN Скачать руководство пользователя страница 21

SECTION 5 - USER INSTRUCTIONS

5.1 CONDITIONS OF INSTALLATION

It is the law that all gas appliances are installed only by a competent (e.g. GAS

SAFE Registered) Installer, in G.B. in accordance with the installation instructions

and the Gas Safety (Installation and Use) Regulations 1998. Failure to install

appliances correctly could lead to prosecution. It is in your own interest and that

of safety to comply with the law.

The fire may be fitted below a combustible shelf provided that the shelf is at least

200mm above the top of the appliance and the depth of the shelf does not exceed

150mm.

The fire may be installed below combustible shelves which exceed 150mm deep

providing that the clearance above the fire is increased by 15mm for each 25mm

of additional overhang in excess of 150mm.

No purpose made additional ventilation is normally required for this

appliance when installed in G.B. When installed I.E. please consult

document I.S. 813 : 1996 Domestic Gas Installation which is issued by the

National Standards Authority of Ireland. Any purpose made ventilation

should be checked periodically to ensure that it is free from obstruction.

If the chimney or flue has been previously used by appliances burning fuels other

than gas they must be swept prior to the installation of this fire.

If this appliance is fitted directly on to a wall without the use of a fireplace or

surround, soft wall coverings such as wallpaper, blown vinyl etc. could be affected

by the heat and hot air and may discolour or scorch. This should be considered

when installing or decorating.

THIS APPLIANCE MUST NOT BE USED IF THE GLASS PANELS ARE

BROKEN OR NOT IN PLACE.

The Model number of this appliance is as stated on the rating plate affixed to the

inner rear panel of the fire and the appliance is manufactured by:-

BFM Europe Ltd

Trentham Lakes

Stoke on Trent

ST4 4TJ

21

Содержание Renoir FRECN0EN

Страница 1: ...GNITION RADIANT CONVECTOR GAS FIRE Installation Maintenance User Instructions Hand these instructions to the user Model No s FRECN0EN FRECR0EN are for use on Natural Gas G20 at a supply pressure of 20...

Страница 2: ...Spillage Monitoring System 8 Section 2 2 1 Packing Check List 9 2 2 Installation of Fire 9 10 2 3 Fitting Spigot to Firebox 11 2 4 Fitting the battery 12 2 5 Gas Tightness 12 Section 3 3 1 Assembly of...

Страница 3: ...h feet fitted 700mm Depth with fender fitted 325mm Height to top of the flue spigot 490mm with feet fitted Gas Connection 8mm compression Supplied with fire EFFICIENCY DECLARATION The efficiency of th...

Страница 4: ...Flues 5 B S 1251 Open Fireplace Components 6 B S 715 Metal Flue pipes for Gas Appliances 7 B S E N 1858 Chinmeys Components Concrete Flue Blocks 8 B S 7566 Installation of factory made Chimneys Ventil...

Страница 5: ...s not project more than 150 mm If the shelf overhangs more than 150 mm the distance between the fire and the shelf must be increased by 25 mm for every 25 mm of additional over hang over 150 mm 1 5 SI...

Страница 6: ...during or after the smoke pellet test and it is important to check inside upstairs rooms adjacent to the chimney flue Check the chimney pot terminal and general condition of the chimney brickwork or...

Страница 7: ...may be fitted if necessary providing that a minimum clearance 50mm between its open end and nearest obstruction is always maintained Fig 1 Chimney Catchment Space 1 8 2 Fitting to Pre Fabricated twin...

Страница 8: ...e removed when installing directly onto a hearth The hearth material must be a minimum thickness of 13 mm with the top surface at least 50 mm above the floor level The hearth must be fitted symmetrica...

Страница 9: ...upwards and lift away See Fig 2 Fig 2 Remove the Glass Panel b Grasp sides of the of the glass panel and pull lower edge forward c Remove the coal fuelbed packs that have been retained by the glass p...

Страница 10: ...there is a definite flow into the opening then proceed with the installation If there is not a definite flow into the opening pre heat the chimney for about two minutes and retest for flow If there s...

Страница 11: ...ing The gas connection should be made to the appliance inlet elbow using 8 mm rigid tubing The gas connection can be made left hand right hand or rear In line with current installation regulations a r...

Страница 12: ...elbow and fit a manometer b Turn on the main gas supply and light the fire as described in section 3 2 and carry out a gas tightness test c Check that the gas pressure is 20 0 mbar 1 0 mbar 8 0 in w...

Страница 13: ...w in Fig 7 The coal form has the individual placement letters stamped on the bottom face Fig 7 13 Coal Form A NOTE The position of the fuel bed components are critical to the performance of the produc...

Страница 14: ...e Fig 8 d Fit coal C onto the fuelbed base in the position as shown below in Fig 9 The coal form has the individual placement letters stamped on the bottom face Fig 9 e Fit coal D onto the fuelbed bas...

Страница 15: ...und the appliance before and after working on the appliance When replacing these articles we recommend that the replaced items are not broken up but are sealed within heavy duty polythene bags clearly...

Страница 16: ...the pilot has lit then release the control knob from the depressed position depress slightly again and turn the control anti clockwise to the high position and check for clear once of combustion produ...

Страница 17: ...fully warm up During this time a slight odour may be noticed this is due to the newness of the fire and will soon disappear 3 4 Final Check a Recheck the operation of the fire on all settings b Make...

Страница 18: ...a gas tightness check must always be carried out 4 1 GENERAL ACCESS FOR SERVICING 4 1 1 TO REMOVE THE UPPER CANOPY GLASS PANEL a Prepare work area lay down dustsheets etc Disconnect the appliance fro...

Страница 19: ...Disconnect the appliance from the gas supply b Remove the burner assembly as shown in section 4 2 c Disconnect the pilot pipe inlet pipe valve to injector pipe and push fit thermocouple as shown belo...

Страница 20: ...13 b Disconnect the pipe pipe and push fit ignition lead c Replacement new ODS in reverse order PARTS SHORTLIST Replacement of any parts must be carried out by a competent person such as a GAS SAFE re...

Страница 21: ...n is normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domestic Gas Installation which is issued by the National Standards Authority of...

Страница 22: ...ning and the chimney or flue visually checked for fallen debris or blockages which must be removed The chimney should also be checked to ensure clearance of flue products During the annual service rep...

Страница 23: ...NG SYSTEM This appliance is fitted with a spillage monitoring system which shuts down the fire if the evacuation of combustion products from the fire is affected by a partially or fully blocked flue I...

Страница 24: ...ove the spill and continue to hold the control knob down for 10 seconds c If the pilot fails to light repeat the ignition sequence and hold in the control knob for slightly longer d When the pilot has...

Страница 25: ...w in Fig 2 The coal form has the individual placement letters stamped on the bottom face Fig 2 NOTE The position of the fuel bed components are critical to the performance of the product Therefore ple...

Страница 26: ...ce Fig 3 d Fit coal C onto the fuelbed base in the position as shown below in Fig 4 The coal form has the individual placement letters stamped on the bottom face Fig 4 e Fit coal D onto the fuelbed ba...

Страница 27: ...nd the appliance before and after working on the appliance When replacing these articles we recommend that the replaced items are not broken up but are sealed within heavy duty polythene bags clearly...

Страница 28: ...THE FIRE FAILING TO LIGHT PLEASE VISUALLY CHECK FOR SPARKING AT THE IGNITION ELECTRODE ON THE PILOT IF NO SPARK IS PRESENT PLEASE REPLACE THE BATTERY AS DETAILED IN SECTION 4 5 ABOVE SERVICE CALLS THA...