Flavel Raglan KBFC**MN Скачать руководство пользователя страница 4

Always keep furniture and combustible materials well clear of the fire and never

dry clothing or items either on or near to the fire. Never use aerosols or

flammable cleaning products near to the fire when it is in use.

The fuel bed remains hot for a considerable period after use and sufficient

time should be allowed for the fire to cool before cleaning etc.

The fire must only be operated with the fender and ash pan cover supplied and in

position.

OPERATING THE FIRE

The controls are located behind the brass cover below the fender. The controls,

comprise a control valve to adjust the gas flow and a push button piezo igniter. To

light the fire proceed as follows:-

1)

Depress the control knob and turn anti-clockwise to the position marked pilot.

Hold in the control knob for a few seconds to allow the gas to reach the pilot.

2)

Continue to hold-in the control knob and press the igniter button. If the pilot

does not light, continue to press the igniter button until ignition occurs. The

pilot flame can be seen by looking across the front line of the burner. When

the pilot has lit, continue to hold the control knob in for 5-10 seconds to allow

the thermocouple to heat up, if the pilot goes out when the control knob is

released, repeat the lighting sequence.

After lighting, turn the control knob in the anti-clockwise direction to the high

position and the main burner will light. To gain the most efficient

performance, it is recommended that the control is left in the high position for

5 to 10 minutes

3)

The gas control can be turned clockwise from the maximum position to give

the desired heat output.

4)

To turn the fire off push in and turn the control valve fully clockwise in to the

off position, the burner and pilot will go out.

WHEN TURNING THE FIRE “OFF” PLEASE ENSURE THAT THE CONTROL

VALVE IS TURNED TO THE “OFF” POSITION AND THE PILOT FLAME IS

EXTINGUISHED. DO NOT LEAVE THE PILOT FLAME ONLY LIT.

WARNING : If the fire goes out for any reason or is turned off and it is neces-

sary to re-light the fire it is important to allow the fire to cool for a full 5 min-

utes before attempting to re-light it.

4

Содержание Raglan KBFC**MN

Страница 1: ...User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No KBFC MN is only for use on Natural Gas G20 at a supply pressu...

Страница 2: ...bove the top of the appliance and the depth of the shelf does not exceed 150mm The fire may be installed below combustible shelves which exceed 150mm deep providing that the clearance above the fire i...

Страница 3: ...g appliances a fireguard should be used for the protection of children the elderly and infirm Fireguards should conform to BS 6539 1984 Fireguards for use with solid fuel appliances Servicing should b...

Страница 4: ...button until ignition occurs The pilot flame can be seen by looking across the front line of the burner When the pilot has lit continue to hold the control knob in for 5 10 seconds to allow the therm...

Страница 5: ...etal parts should be gently cleaned with a damp cloth Abrasive cleaners chemical cleaning agents or any type of pol ish must never be used as damage to the paint may result CLEANING THE FUEL BED We do...

Страница 6: ...glass cleaner DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO CLEAN THE GLASS PANEL WHEN THE APPLIANCE IS RUNNING FOLLOWING CLEANING OF THE GLASS PANEL ALWAYS ENSURE THAT THE ALLEN KEY IS REMOVED FROM THE A...

Страница 7: ...ox FOLLOWING USE OF THE ALLEN KEY ALWAYS REMOVE IT FROM THE FIRE AND REPLACE IT INTO ITS LOCATION IN THE CLIP AT THE BOTTOM LEFT HAND SIDE OF THE FIREBOX REMOVAL RE FITTING OF THE FUELBED FITTING THE...

Страница 8: ...dling these articles but we recommend you follow the normal hygiene rules of not smoking eating or drinking in the work area and always wash your hands before eating or drinking USER REPLACEABLE PARTS...

Отзывы: