Flavel FWERN0MN Скачать руководство пользователя страница 15

Supplied By www.heating spares.co  Tel. 0161 620 6677

MAINTENANCE INSTRUCTIONS

Servicing Notes

Servicing should be carried out annually by a competent person such as a
Corgi registered engineer.  The service should include visually checking the
chimney and fire opening for accumulations of debris and a smoke test to
check for positive up-draught in the chimney.  The condition of the ceramic
plaques should be checked and if necessary the whole set should be replaced
with a genuine replacement set.  After any servicing work a gas tightness
check must always be carried out.  

Ensure before any servicing work is commenced that the applinace is 
isolated from the electrical supply.

4.1

GENERAL ACCESS FOR SERVICING

4.1.1

TO REMOVE THE UPPER CANOPY

a)

Prepare work area (lay down dustsheets etc.), Disconnect the appliance
from the gas supply.

b)

Remove the four canopy rear fixing screws, and the two fixing screws 
that are located on the underside of the canopy (see fig 5 & 6
respec tively)

c)

Remove the radiants and move to a safe place

d)

Re-assemble in the reverse order.

Fig. 5       Removing the four canopy rear fixing screws

15

Fixing Screws

Содержание FWERN0MN

Страница 1: ...Tel 0161 620 6677 WELCOME RADIANT CONVECTOR GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No s FWERN0MN FWERR0MN are for use on Natural Gas G20 at a supp...

Страница 2: ...ations 8 1 9 Hearth Fitting 8 1 10 Wall Mounting 8 1 11 Spillage Monitoring System 8 Section 2 2 1 Packing Check List 9 2 2 Installation of Fire 9 10 2 3 Gas Connection 11 2 4 Gas Soundness 12 Section...

Страница 3: ...ssure 20 0 1 0 mbar 8 0 0 4 in w g Ignition Rotary piezo integral to gas valve Electrode Spark Gap 4 0 mm Weight Packed 21 5 kg Supply Voltage 230V ac 50Hz Fuse Rating 3 Amp Mains Cable 1 x 1 8M PVC 1...

Страница 4: ...n of Gas Pipework 4 B S 6461 Part 1 Installation of Chimneys Flues 5 B S 1251 Open Fireplace Components 6 B S 715 Metal Flue pipes for Gas Appliances 7 B S 1289 Clay Flue blocks and Terminals 8 B S 75...

Страница 5: ...the fire and the shelf does not project more than 150 mm If the shelf overhangs more than 150 mm the distance between the fire and the shelf must be increased by 25 mm for every 25 mm of additional o...

Страница 6: ...e structure of the chimney during or after the smoke pellet test and it is important to check inside upstairs rooms adjacent to the chimney flue Check the chimney pot terminal and general condition of...

Страница 7: ...imum total length of 125mm may be fitted if necessary providing that a minimum clearance 50mm between its open end and nearest obstruction is always maintained Fig 1 Chimney Catchment Space 1 8 2 Fitt...

Страница 8: ...h the top surface at least 50 mm above the floor level The hearth must be fitted symmetrically about the fire opening and have a minimum width of 760 mm and a minimum projection of 300 mm forwards fro...

Страница 9: ...2 2 INSTALLATION OF FIRE 2 2 1 Preparation a Remove the dress guard by springing the location wires out at the top and lifting away See Fig 2 Take care not to scratch the trim Fig 2 Remove the Dress G...

Страница 10: ...plate and observe the smoke If there is a definite flow into the opening then proceed with the instal lation If there is not a definite flow into the opening pre heat the chimney for about two minutes...

Страница 11: ...the appliance inlet elbow using 8 mm rigid tubing The gas connection can be made left hand right hand or rear In line with current installation regulations a restrictor should be fitted to the inlet p...

Страница 12: ...y inserting the upper end first into the radiant canopy and then lowering and seating the base of the radiants into the radiant support channel b Refit the dress guard 3 2 Lighting the Appliance a Lig...

Страница 13: ...e If in doubt repeat the exercise after a further 5 10 minutes Note It is recommended that the smoke match is fitted into an approved smoke match holder when checking for clearance of combustion produ...

Страница 14: ...ure that the User knows how to operate the fire and refer them to the User Book d Inform the User that the Model Number for ordering parts is shown on the Rating plate The rating plate can be viewed a...

Страница 15: ...ced with a genuine replacement set After any servicing work a gas tightness check must always be carried out Ensure before any servicing work is commenced that the applinace is isolated from the elect...

Страница 16: ...g Screws 4 2 REMOVING THE BURNER ASSEMBLY FROM THE FIRE a Disconnect the appliance from the gas supply Fig 7 b Remove the coal form from the front of the appliance as shown above in Fig 7 c Remove the...

Страница 17: ...Tel 0161 620 6677 Fig 8 d Remove the four burner retaining screws as shown below in fig 9 Disconnect the pilot assy and slide the burner carrier to the right and lift clear Fig 9 17 Front bezel retai...

Страница 18: ...eft hand side panel by unscrewing the rear panel fixing screws then the base panel retaining screw as shown below in fig 10 Fig 10 c Disconnect the pipes to the control valve and the control valve loc...

Страница 19: ...ouple position is factory set to a tight tolerance Any replacement of parts on the pilot requires a complete new pilot assembly a Remove the front panel and front bezel as described in section 4 2 b U...

Страница 20: ...y a competent person such as a CORGI registered gas installer or competent electrician The part numbers of the user replaceable parts are as follows these are available from specialist spares stockist...

Страница 21: ...T CONVECTOR GAS FIRE User Instructions This section of the instructions should be read by the user before operating the appliance and retained for future reference Model No s FWERN0MN FWERR0MN are for...

Страница 22: ...l ventilation is normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domestic Gas Installation which is issued by the National Standards...

Страница 23: ...llen debris or blockages which must be removed The chimney should also be checked to ensure clearance of flue products We recommend that during the annual service replacement of the Oxypilot is carrie...

Страница 24: ...cool for 3 minutes before attempting to re light it SPILLAGE MONITORING SYSTEM This appliance is fitted with a spillage monitoring system which shuts down the fire if the evacuation of combustion pro...

Страница 25: ...position marked b When the pilot lights remove the spill and continue to hold the control knob down for 10 seconds c If the pilot fails to light repeat the ignition sequence and hold in the control k...

Страница 26: ...remove the ceramics and brush gently with a soft brush To remove the ceramic remove the dress guard as shown in fig 2 Remove the radiants by lifting them slightly then pulling forward as shown below...

Страница 27: ...Instructions c Remove the bulbs from the bayonet fitting and replace with a new one of the correct specification as shown below in Fig 4 Due to our policy of continual improvement and development the...

Страница 28: ...Supplied By www heating spares co Tel 0161 620 6677...

Страница 29: ...Supplied By www heating spares co Tel 0161 620 6677...

Страница 30: ...Supplied By www heating spares co Tel 0161 620 6677...

Отзывы: