To ensure that the release of fibres from these R.C.F (Refractory Ceramic
Fibre) articles is kept to a minimum, during installation and servicing we 
recommend that you use a HEPA filtered vacuum to remove any dust 
accumulated in and around the appliance before and after working on the 
appliance.  When replacing these articles we recommend that the replaced
items are not broken up, but are sealed within heavy duty polythene bags,
clearly labelled as “RCF waste”.  RCF waste is classed as a “stable”, non
reactive hazardous waste and may be disposed of at a landfill licensed to
accept such waste   Protective clothing is not required when handling these
articles, but we recommend you follow the normal hygiene rules of not
smoking, eating or drinking in the work area, and always wash your hands
before eating or drinking.

USER REPLACEABLE PARTS

The only user replaceable parts on this fire are the fuelbed components and 
coals or pebbles which may be replaced as described in the above section.  Replacement of any other
parts must be carried out by a competent person such as a CORGI registered gas installer. The part
numbers of the user replaceable parts are as follows, these are available from CFM Europe Ltd. who may
be contacted at the number on the rear cover of this book.

Complete Coal Pack

B-91480

Complete Pebble Pack

B-91520

Coal Fuelbed Matrix

B-91500

Pebble Fuel-bed Matrix

B-91540

Coal Fuelbed Front Rail

B-91490

Pebble Fuelbed Front Rail

B-91530

Loose Coal Pack 

B-91510

Loose Pebble Pack

B-91550

Due to our policy of continual improvement and development the exact
accuracy of descriptions and illustrations cannot be guaranteed.

Part no. B-90710

Issue 2

CFM Europe Ltd.

Trentham Lakes

Stoke-on-Trent

Staffordshire

ST4 4TJ

Telephone - General Enquiries :

(01782) 339000

Telephone - Service :

(08700) 101187

Содержание FSSC00MN

Страница 1: ...enance User Instructions Hand these instructions to the user Model No FSSP00MN FSSC00MN are for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I E NOTE TO THE INSTALLER Prior to commenc...

Страница 2: ...re trim assembly 12 13 Section 3 Assembling Fuel Bed and Commissioning 3 1 Fitting the pebble fuel bed set 13 16 3 2 Fitting the coal fuel bed set 17 20 3 3 Lighting the appliance 21 3 4 Checking for...

Страница 3: ...e 500 NG Pilot Type Copreci ODS 21100 141 Max Gross Heat Input 6 9 kW Min Gross Heat Input 4 2 kW Cold Pressure G20 20 0 1 0 mbar 8 0 0 4 in w g Ignition Push Button Piezo Electrode Spark Gap 4 0mm Pa...

Страница 4: ...1251 Open fire place components 5 BS 715 BS EN 1856 2 Metal flue pipes for gas appliances 6 BS EN 1858 Clay Flue Blocks and Terminals 7 IS 813 Domestic Gas Installation Republic of Ireland No purpose...

Страница 5: ...FLUE BOXES The appliance may be fitted to twin wall metal flue boxes conforming to the constructional requirements of BS 715 for example the Selkirk LFE 175 box The box must have a minimum flue diame...

Страница 6: ...packed inside firebox coal or pebble dependent upon model chosen 1 off Installation User Instruction Manual Combined 1 off Loose Items pack 1 off Silver Sapphire top section 1 off Silver Sapphire bas...

Страница 7: ...create an opening as shown in Fig 2 below If installing into a conventional opening with a hearth panel create an opening as shown in Fig 3 below Fig 2 Hole in the Wall Installations Fig 3 Convention...

Страница 8: ...out to check satisfactory clearance of flue products regardless of the type of flue the appliance is being fitted to Proceed as follows a Remove the burner tray by unscrewing the 2 off retaining nuts...

Страница 9: ...ebox See Fig 6a below Fig 6a Note Before breaking into the gas supply a pressure drop test should be carried out to establish that the existing pipework is sound Carefully withdraw the fire box from t...

Страница 10: ...which in turn will damage the burner and control systems of the product Fig 6b below shows a correctly sealed installation Fig 6b PLEASE NOTE Only holes to be left are the specifically sized air relie...

Страница 11: ...screw from the inlet elbow and fit a manometer b Turn on the main gas supply and carry out a gas tightness test c Depress the control knob and turn anti clockwise to the position marked pilot Hold in...

Страница 12: ...of the firebox d Locate the three studs in the upper canopy onto the three protruding flanges at the top of the firebox Once located the inner flange on the lower surface can be secured using the M4 n...

Страница 13: ...r Make sure that the fuelbed base is located centrally in the fire box Ensure that the fuelbed base fit fully down onto the fuel bed support and is not lodged on the burner See fig 9 below Fig 9 NOTE...

Страница 14: ...t ceramic rail is correctly located onto the lip on the burner front ceramic support See fig 10 below Fig 10 c Pick pebbles A to E and arrange along the the front rail ensuring that they are evenly sp...

Страница 15: ...front row of pebbles ensuring that flame paths as indicated below are not interupted See fig 12 below Fig 12 e Select pebbles J N and position to fill the gaps at each end of the third row of pebbles...

Страница 16: ...he release of fibres from these R C F Refractory Ceramic Fibre articles is kept to a minimum during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust accum...

Страница 17: ...e burner See fig 15 below Fig 15 b Position front ceramic rail on burner front ceramic support and ensure that the locating channel in the front ceramic rail is correctly located onto the lip on the b...

Страница 18: ...are evenly spaced Use the recess s in the front ceramic rail as a guide for placement See fig 17 below Fig 17 d Select four of the coals and arrange behind the front row of coals ensuring that flame...

Страница 19: ...long the rear of the fuelbed using the ribs in the rear of the fuelbed as a guide for placement See fig 19 below Fig 19 f Select two coals and position to fill the gaps at each end of the third row of...

Страница 20: ...e articles is kept to a minimum during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust accumulated in and around the appliance before and after working o...

Страница 21: ...l knob is released repeat the lighting sequence d Turn the control knob in the anti clockwise direction to the high position and the main burner will light e Turn the control knob clockwise to the low...

Страница 22: ...functioning correctly and a fault exists If after investigation the fault cannot be traced and rectified the fire must be disconnected from the gas supply and expert advice obtained e If there is an...

Страница 23: ...move the fret cover out of the way and put them in a safe location Remove the loose pebbles or coals from the fuel bed Remove the fuelbed matrix front ceramic rails 4 1 3 Isolate the gas supply and re...

Страница 24: ...set to a tight tolerance Any replacement of parts on the pilot requires a complete new pilot assembly 4 4 1 Remove the burner assembly as in section 4 1 4 4 2 Disconnect the pilot pipe unscrew and re...

Страница 25: ...year by a CORGI registered gas installer and that during the service the fire is removed from the fire opening and the chimney or flue visually checked for fallen debris or blockages which must be rem...

Страница 26: ...t flame When the pilot has lit continue to hold the control knob in for 5 10 seconds to allow the thermocouple to heat up if the pilot goes out when the control knob is released repeat the lighting se...

Страница 27: ...and genuine replacement set and the fire must never be run with the wrong number or damaged coals The fuel bed must be carefully re assembled as stated in section 3 1 USER REPLACEABLE PARTS The only...

Страница 28: ...e fig 23 below Fig 23 b Position front ceramic rail on burner front ceramic support and ensure that the locating channel in the front ceramic rail is correctly located onto the lip on the burner front...

Страница 29: ...re evenly spaced Use the recess s in the front ceramic rail as a guide for placement See fig 25 below Fig 25 d Select pebbles F to I and arrange behind the front row of pebbles ensuring that flame pat...

Страница 30: ...d row of pebbles as shown below in Fig 27 Fig 27 f Select the remaining pebbles K L M which are slightly larger that the other pebbles and arrange along the rear of the fuelbed using the ribs in the r...

Страница 31: ...iance When replacing these articles we recommend that the replaced items are not broken up but are sealed within heavy duty polythene bags clearly labelled as RCF waste RCF waste is classed as a stabl...

Страница 32: ...pport See fig 30 below Fig 30 c Fit five of the coals onto the front ceramic rail ensuring that they are evenly spaced Use the recess s in the front ceramic rail as a guide for placement See fig 31 be...

Страница 33: ...e along the rear of the fuelbed using the ribs in the rear of the fuelbed as a guide for placement See fig 33 below Fig 33 f Select the two small coals and position to fill the gaps at each end of the...

Страница 34: ...n and fit of the coals may be finely adjusted to give the most pleasing and random appearance Warning Use only the coals supplied with the fire When replacing the coals remove the old coals and discar...

Страница 35: ...ng or drinking USER REPLACEABLE PARTS The only user replaceable parts on this fire are the fuelbed components and coals or pebbles which may be replaced as described in the above section Replacement o...

Отзывы: