3.2

LIGHTING THE APPLIANCE

IMPORTANT : IF THE BURNER IS EXTINGUISHED FOR ANY REASON YOU

MUST ENSURE THAT YOU WAIT A FULL FIVE MINUTES BEFORE ATTEMPT-

ING TO RE-LIGHT THE FIRE.

a)

Turn on the gas restrictor at the inlet fitting.

b)

Depress the control knob and turn anti-clockwise to the position marked

pilot. Hold in the control knob for a few seconds to purge the pipe work.

c)

Continue to hold-in the control knob and press the igniter button. If the

burner does not light, continue to press the igniter button until ignition

occurs. Continue to hold the control knob for 5-10 seconds to allow

thermocouple to heat up, if the pilot goes out when the control knob is

released, repeat the lighting sequence.

d)

Turn the control knob in the anti-clockwise direction to the high position

and the main burner will light.

e)

Turn the control knob clockwise to the low position and the gas input

will be reduced to the minimum setting.

f)

Slightly depress the control knob and turn to the pilot position, the main

burner will go out but the pilot will remain lit.

g)

Slightly depress the control knob and turn to the off position, the pilot

will now be extinguished.

h)

After ensuring that the fire is safe to use it should be left on high

position to fully warm up. During this time a slight odour may be

noticed, this is due to the “newness” of the fire and will soon disappear.

WHEN TURNING THE FIRE “OFF” PLEASE ENSURE THAT THE CONTROL

VALVE IS TURNED TO THE “OFF” POSITION AND THE PILOT FLAME IS

EXTINGUISHED. DO NOT LEAVE THE PILOT FLAME ONLY LIT.

3.3

FITTING THE TRIM & FRET

a)

Push the decorative trim onto the magnets on the fire body, and secure

in place. Remove the protective trim before use.

b)

The firebox is supplied with 2 fender fixing brackets and screws which

should be fixed to the holes in the fender, the flanges on the brackets

should be facing towards the outside of the fender.

c)

Place the fender in position by locating the fender brackets between the

trim and the fire body.

d)

Locate the ashpan cover.

Finally, hand the Installation and Maintenance Instructions and the Users

Instructions over to the customer and explain the operation of the fire.

NOTE : THIS APPLIANCE IS DESIGNED TO WORK SAFELY AND

EFFECTIVELY DURING ADVERSE WEATHER CONDITIONS.

HOWEVER, DURING SUCH TIMES FLAME DISTURBANCE MAY BE

NOTICED. THIS IS NORMAL AND DOES NOT EFFECT OR IMPAIR

THE SAFETY OF THE APPLIANCE.

19

Содержание FBFN76G

Страница 1: ...Maintenance Instructions Hand these instructions to the user Model No s FBFN76G FBFN98G are for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I E Model No s FBFP76G FBFP98G are for use...

Страница 2: ...2 7 Securing of the firebox to the wall 12 14 2 8 Preparation for mounting the flue terminal 15 2 9 Fitting the terminal guard 16 2 10 Removal refitting of the glass frame 16 Section 3 Assembling Fuel...

Страница 3: ...g Ignition Push button Piezo Electrode Spark Gap 4 0mm Weight with fender 30 0 kg inclusive of flue pipe and terminal Fig 1 Efficiency Declaration The efficiency of this appliance has been measured a...

Страница 4: ...d In Republic of Ireland No purpose made additional ventilation is normally required for this appli ance when installed in G B When Installing in I E please consult document I S 813 1996 Domestic Gas...

Страница 5: ...ve an opening air brick 300mm 12in opening window C Horizontally to an opening air brick opening window etc D Below gutters soil pipes or drain pipes 300mm 12in E Below eaves 300mm 12in F Below balcon...

Страница 6: ...RE 2 1 UNPACKING THE FIRE Carefully lift the fire out of the carton Remove the loose item packaging carefully from the the pack Check the contents as listed IMPORTANT THE CARDBOARD FITMENT THAT IS AT...

Страница 7: ...ening Any surround must be suitably sealed to the fire place to prevent leakage See fig 3 below Fig 3 A min max sized opening with a flat rear face between the fire opening and flue outlet terminal is...

Страница 8: ...fitted or 125mm without black spacer fitted 2 3 PREPARATION OF THE WALL The appliance and flue pipes must be installed at right angles to the mounting wall The appliance itself should be installed ver...

Страница 9: ...ole To Hammer and chisel proceed as follows Mark the position of the centre of the flue pipe as specified in figure 5 Mark the position of the hole around this point Chisel out the area as marked on t...

Страница 10: ...or the inner flue pipe 87 5mm diameter add an additional 25mm to dimension A and cut the inner flue pipe squarely to length IMPORTANT DO NOT CUT FLANGED ENDS OF FLUE PIPE ENSURE THE PIPES ARE CUT SQUA...

Страница 11: ...er the firebox from the left right or rear and connect to the inlet elbow See below a If concealed pipe work is required plan the pipe run to enter the fire box through one of the openings in the side...

Страница 12: ...e installer to deal with any type of installation The preferred method of fixing the appliance is the cable fixing method which is described in detail in the following section If the standard firebox...

Страница 13: ...h the fixing eye at the bottom d Thread the cables through the rear of the firebox insert the flue pipes through the hole in the rear of the wall and offer the firebox up to the fireplace e Thread the...

Страница 14: ...y out a gas soundness test l Depress the control knob and turn anti clockwise to the position marked pilot Hold in the control knob for a few seconds to purge the pipe work then press the igniter butt...

Страница 15: ...e terminal as a template Remove the flue terminal and drill the 2 off holes 6mm diameter into the wall Insert the raw plugs Replace the terminal onto the flue pipe and secure using the No 12 x 40mm sc...

Страница 16: ...er wall Remove the terminal guard and drill the 4 off 6 mm holes Insert the raw plugs into the drilled holes replace the terminal guard over the top of the flue terminal and attach to the wall using t...

Страница 17: ...ghtening each allen bolt a small amount at a time to prevent stressing the glass panel f Fit the allen key to the bracket which is situated at the bottom left hand corner of the firebox and advise the...

Страница 18: ...emove any dust accumulated in and around the appliance before and after working on the appliance When replacing these articles we recommend that the replaced items are not broken up but are sealed wit...

Страница 19: ...turn to the off position the pilot will now be extinguished h After ensuring that the fire is safe to use it should be left on high position to fully warm up During this time a slight odour may be no...

Страница 20: ...move the glass frame as shown on page 17 then remove the 2 off fixing screws which hold the pilot shield in place 4 1 3 Loosen the pilot pipe disconnect the ignition lead from the electrode and discon...

Страница 21: ...hich is located to the left hand side of the convection air aperture 4 3 4 Loosen the pilot pipe disconnect the ignition lead from the electrode and disconnect the thermocouple from the pilot assembly...

Страница 22: ......

Страница 23: ......

Страница 24: ...SHORTLIST Replacement of parts must be carried out by a competent person such as a CORGI registered gas installer The part numbers of the replaceable parts are as follows these are available from your...

Отзывы: