1.3

FIREPLACE / SURROUND SUITABILITY

The fire must only be installed on a hearth it must not be installed directly onto
carpet or other combustible floor materials.
The fire is suitable for fitting to non-combustible fire place surrounds and propri-

etary fire place surrounds with a temperature rating of at least 150oc.
If a heating appliance is fitted directly against a wall without the use of a fire
surround or fire place all combustible material must be removed from behind
the trim.  Soft wall coverings such as blown vinyl, wall paper etc. could be
affected by the rising hot air and scorching and/or discoloration may result.
Due consideration should be made to this when installing or decorating.

1.4

SHELF POSITION

The fire may be fitted below a combustible shelf providing there is a minimum 
distance of 200mm above the top of the fire and the shelf does not project more
than 150mm.  If the shelf overhangs more than 150mm the distance between the
fire and the shelf must be increased by 15mm for every 25mm of additional 
overhang over 150mm.

1.5

FLUE / CHIMNEY INSPECTION

Before commencing installation, a flue or chimney should be inspected to ensure
that all the following conditions are satisfied.

1.

Check that the chimney / flue only serves one fire place and is clear of any
obstruction.  Any dampers or register plates must be removed or locked in 
the open position.

2.

Brick/stone built chimneys or any chimney or flue which has been used for 
an appliance burning fuel other than gas must be thoroughly swept.  The 
base of the chimney / flue must also be thoroughly cleared of debris etc.

3.

Any under-floor air supply to the fire place must be completely sealed off.

4.

Ensure that the inside of the chimney / flue is in good condition along it’s
length and check that there is no leakage of smoke through the structure 
of the chimney during and after the smoke pellet test.  With pre-cast flues
it is especially important to check the inside of the flue for extruded 
cement / sealant protruding from the joints between the flue 
blocks.  If present, these should be removed by rodding the flue 
before proceeding with the installation.

5.

Using a smoke pellet, check that there is an up-draught in the 
chimney / flue and that the smoke can be seen issuing from the 
terminal / chimney pot outside.  

5

Содержание Enchant FSCP**MN

Страница 1: ...0 6677 Enchant PEBBLE FUEL EFFECT GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No s FSCP MN is only for use on Natural Gas G20 at a supply pressure of 2...

Страница 2: ...hs 9 1 11 Spillage Monitoring System 9 Section 2 Installation of Fire 2 1 Unpacking the fire 10 2 2 Installing the fire box 10 2 3 Gas soundness and burner pressure 15 16 Section 3 Assembling Fuel Bed...

Страница 3: ...preci Single Flame 21100 141 or S I T Dual Flame YA OP 9022 Max Gross Heat Input 6 5 kW Min Gross Heat Input 4 2 kW Cold Pressure 20 0 1 0 mbar Ignition Push button Piezo Electrode Spark Gap 4 5mm Pac...

Страница 4: ...s 7 B S 1289 Clay Flue Blocks and Terminals 8 I S 813 1996 Domestic Gas Installation Republic of Ireland No purpose made additional ventilation is normally required for this appli ance when installed...

Страница 5: ...f additional overhang over 150mm 1 5 FLUE CHIMNEY INSPECTION Before commencing installation a flue or chimney should be inspected to ensure that all the following conditions are satisfied 1 Check that...

Страница 6: ...e test must always be carried out during commissioning of the appliance 1 6 FIRE PLACE OPENING AND CHIMNEY CATCHMENT SPACE The front opening of the fire place must be between 330 and 440 mm wide and b...

Страница 7: ...volume fig 2 Opening Width mm Minimum Depth Required mm 330 minimum opening width 222 340 218 350 215 360 211 370 205 380 199 390 193 400 189 410 183 420 178 430 172 440 maximum opening width 168 For...

Страница 8: ...pth To increase this depth the fire surround may be packed away from the wall using suitable non combustible board providing the installation is correctly sealed If in doubt about the suitability of t...

Страница 9: ...g system in the form of an oxygen sensing pilot This is designed to shut the fire off in the event of a partial or complete blockage of the flue causing a build up of combus tion products in the room...

Страница 10: ...nlessTrim 1off each User instruction book and Installation book 2 2 INSTALLING THE FIRE BOX Establish which type of flue you are intending to install the fire in to 225 x 225mm 9 inch x 9 inch brick b...

Страница 11: ...that the hearth is protected from damage and carefully lift the fire box into the fire opening then slide it back into position Check that the fire box flange fits flush to the sealing face of the fir...

Страница 12: ...nlet elbow The gas connection to the appliance should be made to the isolating inlet elbow using 8mm rigid tubing There must be no soldered joints within the firebox See fig 5 6 below for suggested co...

Страница 13: ...f fire opening To fit using the preferred cable method proceed as follows e Mark out and drill 4 off No 14 7mm holes in the back face of the fire opening in the positions shown below in fig 7 Fig 7 Fi...

Страница 14: ...travel for the tensioning nut i Fit a screwed nipple on to each of the cables and pull hand tight up against the tensioning screw then secure each nipple with a flat bladed screwdriver See fig 8 below...

Страница 15: ...n rear of fire opening the firebox can be secured to the fire surround using four screws and wall plugs provided Below fig 9 is a diagram to indicate the hole centre positions available on the firebox...

Страница 16: ...re test point screw for gas soundness with the appliance turned on using a suitable leak detection fluid or detector SECTION 3 ASSEMBLING FUEL BED AND COMMISSIONING 3 1 ASSEMBLING THE FUEL BED a Place...

Страница 17: ...ing channel in the front ceramic ensuring they are located onto the lip on the burner front ceramic support See fig 11 below Fig 11 c Select six of the small pebbles and position evenly along the fron...

Страница 18: ...flame paths as indicated below are not interupted See fig 13 Fig 13 e Select 2 of the large pebbles and position along the back row of the fuelbed using the location indents on the back section of th...

Страница 19: ...tion marked pilot Hold in the control knob for a few seconds to purge the pipe work c Continue to hold in the control knob and press the igniter button If the burner does not light continue to press t...

Страница 20: ...utes If the test indicates that spillage is occurring and the flue restrictor baffle has been fitted it should be removed and the test repeated after the fire has cooled d If spillage persists the flu...

Страница 21: ...ay and put them in a safe location Remove the loose pebbles from the fuel bed and front ceramic rail Remove the front ceramic from the rail Unscrew the two pozi driv fixing screws which secure the bur...

Страница 22: ...ontrol tap locates with a flat in the control panel Carry out a gas soundness test after re assembly 4 4 Removing the Oxy Pilot Assembly Note Because this appliance is fitted with an atmosphere sensin...

Страница 23: ...55640 Replacement pebble set B 68970 L H Fibre Board B 56530 R H Fibre Board B 56520 Upper Rear Fibre Board B 56540 Lower Rear Fibre Board B 56550 Piezo Igniter B 1320 Ignition Wire B 14340 Gas Valve...

Страница 24: ...Supplied By www heating spares co Tel 0161 620 6677...

Отзывы: