OPERATING THE FIRE

a)

Light the pilot by depressing the control knob at the “off” position and 
turn anti-clockwise (with the control depressed) to the second position 
marked *.

b)

When the pilot lights, (pilot can be seen between the coals and fuelbed 
base through the side window) hold the control knob down for 10 
seconds.

c)

If the pilot fails to light, repeat the ignition sequence and hold in the 
control knob for slightly longer.

d)

When the pilot has lit, release the control knob from the depress
position, depress slightly again and turn the control anti-clockwise to the
HIGH position.

e)

It is recommended that the fire is left in the HIGH position to warm up 
for approximately 10 minutes before turning to the required heat setting.

WARNING
If the fire goes out for any reason or is turned off and it is
necessary to relight the fire it is important to allow the fire to cool 
for 3 minutes before attempting to re-light it.

SPILLAGE MONITORING SYSTEM

This appliance is fitted with a spillage monitoring system which shuts down the fire
if the evacuation of combustion products from the fire is affected by a partially or
fully blocked flue.
If this system operates the fire will go out.  If this occurs, leave the fire for at least
three minutes then follow the lighting procedure as described in the previous 
section.  In the event of repeated operation a CORGI registered gas installer
must be called to investigate and rectify the cause.

CLEANING - WARNING

Before attempting any cleaning operation ensure that the fire has been allowed to
fully cool.  

CLEANING THE FUELBED / COALS

We do not recommend regular cleaning of the fuelbed ceramics as these are 
fragile and damage may result.  None of these parts must be washed or
exposed to any cleaning agents or water
.
Any damaged parts must be replaced by contacting your dealer or telephoning
CFM Europe Ltd. on the number stated on the rear cover of this book.  The 
fuelbed ceramics must only be replaced with a complete and genuine replacement
set and the fire must never be run with the wrong number or damaged coals. The
fuelbed ceramics must be carefully re-assembled as stated in pages 6 - 8 of this
book.

4

Содержание Emberglow Classic FEMC00MN

Страница 1: ...ation and Maintenance Instructions Hand these instructions to the user Model No FEMC00MN is for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I E Model No FEMC00MP is for use on Propan...

Страница 2: ...Flue Installations 8 1 9 Hearth Fitting 8 1 10 Spillage Monitoring System 8 Section 2 2 1 Packing Check List 9 2 2 Installation of Fire 9 10 2 3 Fitting Canopy Rear Trim 11 2 4 Fitting Canopy to Fireb...

Страница 3: ...nput 1 8 kW 1 70kW Cold Pressure 20 0 1 0 mbar 8 0 0 4 in w g G20 model 37 0 1 0 mbar 14 8 0 4 in w g G31 model Ignition Rotary piezo integral to gas valve Electrode Spark Gap 4 0 mm Weight Packed 26...

Страница 4: ...imneys Flues 5 B S 1251 Open Fireplace Components 6 B S 715 Metal Flue pipes for Gas Appliances 7 B S 1289 Clay Flue blocks and Terminals 8 B S 7566 Installation of factory made Chimneys Ventilation R...

Страница 5: ...es not project more than 150 mm If the shelf overhangs more than 150 mm the distance between the fire and the shelf must be increased by 25 mm for every 25 mm of additional over hang over 150 mm 1 5 S...

Страница 6: ...during or after the smoke pellet test and it is important to check inside upstairs rooms adjacent to the chimney flue Check the chimney pot terminal and general condition of the chimney brickwork or...

Страница 7: ...may be fitted if necessary providing that a minimum clearance 50mm between its open end and nearest obstruction is always maintained Fig 1 Chimney Catchment Space 1 8 2 Fitting to Pre Fabricated twin...

Страница 8: ...th The hearth material must be a minimum thickness of 13 mm with the outer perimeter of the hearth panel at least 50 mm above the floor level to discourage the placing of carpet or other floor coverin...

Страница 9: ...lass panel upwards and lift away See Fig 2 Fig 2 Remove the Glass Panel b Grasp sides of the of the glass panel and pull lower edge forward c Remove the coal fuelbed packs that have been retained by t...

Страница 10: ...there is a definite flow into the opening then proceed with the instal lation If there is not a definite flow into the opening pre heat the chimney for about two minutes and retest for flow If there s...

Страница 11: ...ia the four fixings screws 2 off L H 2 off R H as shown below in Fig 4 Fig 4 2 4 FITTING THE CANOPY TO THE FIREBOX a Secure the canopy to the firebox with the four screws 2 off L H 2 off R H as shown...

Страница 12: ...air purposes Before making the final gas connection thoroughly purge the gas supply pipe work to remove all foreign matter otherwise serious damage may be caused to the gas control valve on the fire 2...

Страница 13: ...lbed base into the combustion chamber as shown below in Fig 7 Fig 7 b Fit coal A onto the fuelbed base in the position as shown below in Fig 8 The coal form has the individual placement letters stampe...

Страница 14: ...9 The coal form has the individual placement letters stamped on the bottom face Fig 9 d Fit coal C onto the fuelbed base in the position as shown below in Fig 10 The coal form has the individual place...

Страница 15: ...11 f Fit coal E onto the fuelbed base in the position as shown below in Fig 12 The coal from has the individual placement letters stamped on the bottom face Fig 12 Refit the Front Casting which locate...

Страница 16: ...E FIRE MUST ONLY BE OPERATED WITH THE FRONT CASTING IN PLACE 3 3 Checking for Clearance of Combustion Products a Close all doors and windows in the room b Light the fire and turn to the maximum positi...

Страница 17: ...air supply to the room e After ensuring that the fire is safe to use it should be left on High position to fully warm up During this time a slight odour may be noticed this is due to the newness of t...

Страница 18: ...ried out 4 1 GENERAL ACCESS FOR SERVICING 4 1 1 TO REMOVE THE UPPER CANOPY GLASS PANEL a Prepare work area lay down dustsheets etc Disconnect the appliance from the gas supply b Remove the four canopy...

Страница 19: ...CONTROL TAP FROM THE FIRE a Disconnect the appliance from the gas supply b Remove the burner assembly as shown in section 4 2 c Disconnect the pilot pipe inlet pipe valve to injector pipe and push fi...

Страница 20: ...ws as described in section 4 2 d fig 14 b Disconnect the pipe pipe and push fit ignition lead c Replacement new ODS in reverse order and carry out a gas tightness test PARTS SHORTLIST Replacement of a...

Страница 21: ...ctions This section of the instructions should be read by the user before operating the appliance and retained for future reference Model No FEMC00MN is for use on Natural Gas G20 at a supply pressure...

Страница 22: ...normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domestic Gas Installation which is issued by the National Standards Authority of Ire...

Страница 23: ...rom the fire opening and the chimney or flue visually checked for fallen debris or blockages which must be removed The chimney should also be checked to ensure clearance of flue products We recommend...

Страница 24: ...ith a spillage monitoring system which shuts down the fire if the evacuation of combustion products from the fire is affected by a partially or fully blocked flue If this system operates the fire will...

Страница 25: ...When the pilot lights remove the spill and continue to hold the control knob down for 10 seconds c If the pilot fails to light repeat the ignition sequence and hold in the control knob for slightly l...

Страница 26: ...lbed base into the combustion chamber as shown below in Fig 1 Fig 1 b Fit coal A onto the fuelbed base in the position as shown below in Fig 2 The coal form has the individual placement letters stampe...

Страница 27: ...3 The coal form has the individual placement letters stamped on the bottom face Fig 3 d Fit coal C onto the fuelbed base in the position as shown below in Fig 4 The coal form has the individual place...

Страница 28: ...stamped on the bottom face Fig 5 f Fit coal E onto the fuelbed base in the position as shown below in Fig 6 The coal form has the individual placement letters stamped on the bottom face Fig 6 Ensure t...

Страница 29: ...lopment the exact accuracy of descriptions and illustrations cannot be guaranteed Part no B 65360 Issue 5 CFM Europe Ltd Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Telephone General Enquiries...

Страница 30: ......

Отзывы: