Flavel Diamond HE Скачать руководство пользователя страница 17

The preferred method of fixing which is suitable for almost all situations is

the cable fixing method which is described in the following section in detail.

To fit using the

preferred

cable method proceed as follows-

j)

Mark out and drill 4 off No 14 (6mm) holes in the back face of the fire

opening in the positions shown below in fig. 17.

Fig. 17

Fit the wallplugs provided and screw the fixing eyes securely into the rear of the

fire opening. If the clearance at the rear of the fire is at the minimum specified for

a precast flue application, it may be necessary to bend over the lower fixing eyes

after screwing them fully in to the rear of a pre-cast starter block.

k)

Uncoil the two fire fixing cables and thread one end of each of the

cables through one of the two holes on each side of the flue outlet

shroud.

l)

Position the fire carefully on the (protected) surface of the hearth and

reach into the fire opening. Thread each of the cables vertically

downwards through the pair of fixing eyes on the same side of the fire.

Thread the free end of the cables through the corresponding circular

hole on each side of the lower rear of the fire. Carefully slide the fire

box back into the fire opening and pull both cables tight.

m)

Thread a tensioning screw over each of the cables and ensure that the

tensioning nut is screwed fully up against the hexagon shoulder of the

tensioning screw (this provides maximum travel for the tensioning nut).

n)

Fit a screwed nipple on to each of the cables and pull hand tight up

against the tensioning screw, then secure each nipple with a flat

bladed screwdriver. See fig. 18 overpage.

17

20mm

500mm

Fireplace Opening

100mm

250mm

Содержание Diamond HE

Страница 1: ...RE Installation Maintenance User Instructions Hand these instructions to the user Model No s FHKC MN2 FHKC SN2 FHKC RN2 FHLC MN2 FHLP MN2 FHDC RN2 FHDP RN2 are only for use on Natural Gas G20 at a sup...

Страница 2: ...one piece HITW fascia Passion models 35 3 11 Checking for clearance of combustion products 36 Section 4 5 Maintenance 4 1 Removal of the Burner Assembly Manual Control models 37 4 2 Removal of the Pie...

Страница 3: ...70mm Height with standard trim no spacer 586mm Depth overall without fender 180mm Depth Flush fit from mounting face to rear 180mm Depth Flush fit mounting face to rear 130mm with 50mm spacer fitted G...

Страница 4: ...c Gas Installation Republic of Ireland No purpose made additional ventilation is normally required for this appliance when installed in G B When Installing in I E please consult document I S 813 1996...

Страница 5: ...5mm of additional overhang over 150mm 1 5 FLUE CHIMNEY INSPECTION Before commencing installation a flue or chimney should be inspected to ensure that all the following conditions are satisfied 1 Check...

Страница 6: ...E The front opening of the fire place must be between 370 and 450 mm wide and between 550 and 570mm high If the opening exceeds these dimensions then a surround must be constructed from suitable non c...

Страница 7: ...L METAL FLUE BOXES The appliance may be fitted to twin wall metal flue boxes conforming to the constructional requirements of BS 715 for example the Selkirk LFE 175 box The box must have a minimum flu...

Страница 8: ...condition and is free from extruded mortar or sealant from between the flue blocks This appliance has been tested for use in a pre cast flue block complying with BS EN 1858 In accordance with BS EN 18...

Страница 9: ...ers safety and in accordance with BS 5871 2 the fitting of a hearth panel or physical barrier should be carried out Should this advice not be followed however please give consideration to the safety o...

Страница 10: ...r lined brick or stone flue insulated pre fabricated metal flue box to BS 715 BS EN 1856 2 When installing into 125mm 5 inch diameter lined brick or stone flue or insulated pre fabricated metal flue b...

Страница 11: ...t is secured via the two screws as indicated See fig 6 below Fig 6 b Remove the left and right hand side glass securing brackets from the product They are secured via 3 off screws each side See fig 7...

Страница 12: ...rds and clear from the firebox taking care not to damage the glass panel See fig 8 below Fig 8 d Remove the burner heat shield which is retained by 2 off screws as shown below in fig 9 Fig 9 12 Burner...

Страница 13: ...ll allow removal of the complete burner unit from the firebox Fig 10 For all Remote Control models proceed as follows f Remove the two off screws from the left and right hand burner mounting brackets...

Страница 14: ...le out from its fixing hole Release the other end of the cable by pushing the cable forwards to the right i e into the operating arm so as to release the tension Pull the cable nipple out of the retai...

Страница 15: ...n to the appliance should be made to the isolating inlet elbow using 8mm rigid tubing There must be no soldered joints within the firebox See fig 14 15 below for suggested concealed pipe layouts Fig 1...

Страница 16: ...tape as supplied Failure to seal these inlet apertures could lead to flame reversal which in turn will damage the burner and control systems of the product Fig 16 below shows a correctly sealed insta...

Страница 17: ...of the cables through one of the two holes on each side of the flue outlet shroud l Position the fire carefully on the protected surface of the hearth and reach into the fire opening Thread each of t...

Страница 18: ...the access holes in the sides of the fire the holes should be closed around the pipe to prevent leakage of air through the gap around the pipe q Refit the burner Fit the four retaining screws on and...

Страница 19: ...meter b Turn on the main gas supply and carry out a gas tightness test c Depress the control knob and turn anti clockwise to the position marked pilot Hold in the control knob for a few seconds to pur...

Страница 20: ...test point screw Check the pressure test point screw for gas tightness with the appliance turned on using a suitable leak detection fluid or detector 2 5 GAS TIGHTNESS AND INLET PRESSURE REMOTE CONTRO...

Страница 21: ...rts as indicated by the arrows are not blocked by the fuel bed matrix See fig 20 21 below Fig 20 Fig 21 21 Check air ports in fuel bed base panel are not obstructed If these air ports are not in line...

Страница 22: ...front ceramic coal support onto the burner support as shown below in Fig 22 Fig 22 c Fit the front row left hand coal as shown below in Fig 23 Fig 23 22 Positioning of front ceramic coal support onto...

Страница 23: ...d Fit the front row left hand side central coal as shown below in Fig 24 Fig 24 e Fit the front row right hand side central coal as shown below in Fig 25 Fig 25 23...

Страница 24: ...t hand coal as shown below in Fig 26 Fig 26 g Fit the rear row of 3 coals as shown below in Fig 27 Fig 27 The exact position and fit of the coals may be very finely adjusted to give the most pleasing...

Страница 25: ...after working on the appliance When replacing these articles we recommend that the replaced items are not broken up but are sealed within heavy duty polythene bags clearly labelled as RCF waste RCF wa...

Страница 26: ...the arrows are not blocked by the fuel bed matrix See fig 28 29 below Fig 28 Fig 29 NOTE The position of the fuel bed components are critical to the performance of the product Therefore please ensure...

Страница 27: ...d pebbles as shown below in fig 31 Ensure that the cut out in the rear face of the pebbles is positioned as indicated The 4 off specially shaped pebbles are packed in a bag with a label FR on them Fig...

Страница 28: ...and position on the three central ribs in the fuelbed as indicated in Fig 32 below Fig 32 e Select the two small pebbles and arrange along the second row of the fuelbed See fig 33 below Fig 33 28 3 of...

Страница 29: ...uel bed base in fig 34 below Fig 34 g Do a final check that the pebbles are layed out as shown below in Fig 35 Fig 35 The exact position and fit of the pebbles may be very finely adjusted to give the...

Страница 30: ...not smoking eating or drinking in the work area and always wash your hands before eating or drinking h Replace the glass panel and retaining trims as described on pages 11 12 NEVER USE THE FIRE WITHOU...

Страница 31: ...bove the burner heat shield at the front left hand side of the fuel When the pilot has lit continue to hold the control lever down for 5 10 seconds to allow the thermocouple to heat up before releasin...

Страница 32: ...please ensure that the battery pack is re connected as shown in section b c below b Locate the battery pack in the support cradle at the bottom R H side of the firebox burner assembly c The wire and...

Страница 33: ...hosen with the product Fig 37 below shows the self adhesive pad and infrared eye attached to the flying lead as supplied from the factory Fig 37 b Remove the backing paper from the self adhesive pad a...

Страница 34: ...ter a few seconds an audible clicking can be heard and then the fire will light the pilot and then light the main burner The ignition cycle will take approximately 20 seconds 3 To reduce the level of...

Страница 35: ...the factory therefore please consult your local retailer for fitting advice on the type of fret supplied with these models 3 9 FITTING THE ONE PIECE FASCIA S Linear Models a Remove the protective cove...

Страница 36: ...removed and the test repeated after the fire has cooled d If spillage persists the flue is not functioning correctly and a fault exists If after investigation the fault cannot be traced and rectified...

Страница 37: ...sheets etc 4 1 2 Remove the trim Lift the fender and ash pan cover out of the way and put them in a safe location Remove the glass panel unscrewing the top and side retaining brackets see page 11 12 o...

Страница 38: ...Unscrew the control tap locknut from the front of the control panel and remove the control tap 4 3 5 To refit a control tap reassemble in reverse order noting that the control tap locates with a flat...

Страница 39: ...gas tightness test Refit the burner heat shield then refit the coals pebbles referring to section 3 for the correct coal layout Refit the glass panel and glass panel retaining trims The fender and as...

Страница 40: ...end of the cable by pushing the cable towards the right i e into the operating arm so as to release the tension Pull the cable nipple out of the retaining hole and remove the cable through the slot in...

Страница 41: ...orrect coal pebble layout Refit the glass panel and glass panel retaining trims The fender and ash pan cover or fascia can now be re positioned 4 7 Replacing the battery SC models 4 7 1 Unscrew Batter...

Страница 42: ...cable guide tubes 4 9 3 To fit the replacement cable thread the end of the new cable into the long length of p t f e sleeve as supplied taking care not to kink the sleeve Now carefully feed the sleev...

Страница 43: ...ly Remote Control Fires For Diagrams refer to section 2 5 1 Removing the RC Burner Assembly RC models 5 1 1 Prepare work area lay down dust sheets etc 5 1 2 Remove the trim Lift the fender and ash pan...

Страница 44: ...dust sheets etc 5 3 2 Remove the burner assembly as described in section 5 1 5 3 3 Loosen the pilot nut and remove the two screws retaining the pilot assembly Unscrew the thermocouple from the gas va...

Страница 45: ...fuelbed base B 109980 Diamond Linear pebble fuelbed front rail B 126520 Diamond Linear replacement pebble set B 110020 Kenilworth Diamond complete coal ceramic set B 121600 Kenilworth Diamond coal fue...

Страница 46: ...0mm No purpose made additional ventilation is normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domestic Gas Installation which is issu...

Страница 47: ...he fire is removed from the fire opening and the chimney or flue visually checked for fallen debris or blockages which must be removed The chimney should also be checked to ensure clearance of flue pr...

Страница 48: ...to heat up if the pilot goes out when the control knob is released repeat the lighting sequence In the unlikely event of a failure of the igniter the fire can be lit as follows Remove the fret ashpan...

Страница 49: ...ter a few seconds an audible clicking can be heard and then the fire will light the pilot and then light the main burner The ignition cycle will take approximately 20 seconds 3 To reduce the level of...

Страница 50: ...plete see Fig 2 below d When the fire has shut down release the emergency shut off switch e The appliance will now remain in the off position until activated by the remote handset Fig 2 REPLACING THE...

Страница 51: ...latched if the pilot goes out when the control lever is released repeat the lighting sequence In the unlikely event of a failure of the igniter firstly check the operation of the 1 5V battery and if n...

Страница 52: ...ure the air ports as indicated by the arrows are not blocked by the fuel bed matrix See fig 3 4 below Fig 3 Fig 4 52 NOTE The position of the fuel bed components are critical to the performance of the...

Страница 53: ...e front ceramic coal support onto the burner support as shown below in Fig 5 Fig 5 c Fit the front row left hand coal as shown below in Fig 6 Fig 6 53 Positioning of front ceramic coal support onto bu...

Страница 54: ...d Fit the front row left hand side central coal as shown below in Fig 7 Fig 7 e Fit the front row right hand side central coal as shown below in Fig 8 Fig 8 54...

Страница 55: ...ht hand coal as shown below in Fig 9 Fig 9 g Fit the rear row of 3 coals as shown below in Fig 10 Fig 10 The exact position and fit of the coals may be very finely adjusted to give the most pleasing a...

Страница 56: ...after working on the appliance When replacing these articles we recommend that the replaced items are not broken up but are sealed within heavy duty polythene bags clearly labelled as RCF waste RCF wa...

Страница 57: ...cated centrally in the fire box Ensure that the fuelbed base fit fully down onto the fuel bed support and is not lodged on the burner Ensure the air ports as indicated by the arrows are not blocked by...

Страница 58: ...d pebbles as shown below in fig 14 Ensure that the cut out in the rear face of the pebbles is positioned as indicated The 4 off specially shaped pebbles are packed in a bag with a label FR on them Fig...

Страница 59: ...and position on the three central ribs in the fuelbed as indicated in Fig 15 below Fig 15 e Select the two small pebbles and arrange along the second row of the fuelbed See fig 16 below Fig 16 59 3 of...

Страница 60: ...uel bed base in fig 17 below Fig 17 g Do a final check that the pebbles are layed out as shown below in Fig 18 Fig 18 The exact position and fit of the pebbles may be very finely adjusted to give the...

Страница 61: ...ACKED 6 5 CLEANING THE FIRE WARNING Before attempting any cleaning operation ensure that the fire has been allowed to fully cool Consult your retailer to determine what trim fret fascia option was sup...

Страница 62: ...ed as described in section 6 3 6 4 In order to replace the fuel bed components the glass panel of the appliance will need to be removed please refer to pages 11 12 of this book for details on how to r...

Страница 63: ...of illustrations and descriptions contained in this book cannot be guaranteed Part No B 124970 Issue 4 BFM Europe Ltd Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ www bfm europe com Telephone...

Отзывы: