Fig. 4

g)

The fire can now be switched between HIGH rate heat input and LOW

rate heat input by pressing the “DOWN” arrow on the handset. To

reduce the flame height of the main burner incrementally, press the

arrow momentarily. To reduce the heat input directly down to the mini

mum level, press the “SMALL” flame arrow on the handset twice,

NOTE : The flame will go to HIGH rate heat input before going to

designated LOW rate heat input. To return back to HIGH rate heat input

press the “LARGE” flame button twice. To put the fire in In “STANDBY

MODE” (only the pilot remains lit) press and hold the “SMALL” flame

arrow on the handset.

AFTER THE PILOT FLAME HAS BEEN EXTINGUISHED, IF YOU

WISH TO RE-LIGHT THE APPLIANCE YOU MUST WAIT AT LEAST

THREE MINUTES BEFORE TRYING TO RE-LIGHT THE FIRE.

6

“STAR” / “OFF” button

“UP” button

“DOWN” / “STANDBY”

button

“LED” handset light

Содержание Curve FCRR Series

Страница 1: ...Curve RADIANT FLAME EFFECT GAS FIRE User Instructions Model No s FCRR RN is for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I E NB refers to fascia variant...

Страница 2: ...ance above the fire is increased by 15mm for each 25mm of additional overhang in excess of 150mm No purpose made additional ventilation is normally required for this appliance when installed in G B Wh...

Страница 3: ...iced at least once a year by a CORGI registered gas installer in G B and that during the service the fire is removed from the fire opening and the flue pipe visually checked for debris or blockages wh...

Страница 4: ...described in the previous section In the event of repeated operation a CORGI registered gas installer must be called to investigate and rectify the cause REMOVAL OF THE CONTROLS COVER The controls cov...

Страница 5: ...sc set in the MAN position d Switch the main valve knob to the OFF position Image above shows MAIN VALVE knob set in the OFF position e Press and hold the STAR button and UP button on the remote hand...

Страница 6: ...handset twice NOTE The flame will go to HIGH rate heat input before going to designated LOW rate heat input To return back to HIGH rate heat input press the LARGE flame button twice To put the fire in...

Страница 7: ...ounting brackets as shown in Fig 5 below then securing with two screws on the bottom face of the trim as shown in Fig 6 below Fig 5 Fig 6 7 Align mounting bracket on Curve fascia with mounting bracket...

Страница 8: ...ly be replaced with a complete and genuine item and the fire must never be run with a damaged item in position The ceramic fibre back used in this product is manuafctured from R C F Refractory Ceramic...

Страница 9: ...engineer Due to our policy of continual improvement and development the exact accuracy of descriptions and illustrations cannot be guaranteed Part No B 106080 Issue 3 BFM Europe Ltd Trentham Lakes Sto...