Flavel Castelle Скачать руководство пользователя страница 34

5.2

OPERATING THE FIRE - REMOTE CONTROL VARIANTS

5.2.1

Open the controls access door. The control valve is positioned in the

centre of the fire when viewed from the front.

5.2.2

To operate the appliance automatically via the remote control handset,

ensure that the on / off switch is switched to the “on” position as shown

below in figure 1.

Fig. 1

5.2.3

Switch the MANUAL control disc to the “ON” position.

5.2.4

Switch the main valve knob to the “OFF” position.

5.2.5

Press and hold the “STAR” button and “UP” button on the remote hand

set simultaneously, see figure 2 overpage for image of handset.

5.2.6

The valve will then emit an audible beep and commence its ignition

sequence. When the pilot flame has been established, the control will

continue to beep whilst the thermocouple heats up. When the

thermocouple has reached operating temperature, it will allow gas to

flow to the burner and the burner will light at high rate heat input.

34

On / Off Switch

“MANUAL”

Control Disk

“MAIN VALVE” Knob

Содержание Castelle

Страница 1: ...S FIRE Installation Maintenance User Instructions Hand these instructions to the user following installation Model No s FPCL RN is only for use on Natural Gas G20 at a supply pressure of 20 mbar in G...

Страница 2: ...8 22 3 2 Fitting the fascia 23 3 3 Lighting the appliance 24 25 3 4 Checking for clearance of combustion 33 products 3 5 Removal re fitting the draught diverter cover 27 3 6 Removal re fitting the flu...

Страница 3: ...50mm Height with fascia fitted 600mm Depth overall with fascia 223mm Depth from mounting face 75mm Gas Connection 8mm Compression Supplied with fire Efficiency Declaration The efficiency of this appli...

Страница 4: ...1858 Clay Flue Blocks and Terminals 7 IS 813 1996 Domestic Gas Installation Republic of Ireland No purpose made additional ventilation is normally required for this appliance when installed in G B Whe...

Страница 5: ...ang over 150mm 1 5 FLUE CHIMNEY INSPECTION Before commencing installation a flue or chimney should be inspected to ensure that all the following conditions are satisfied 1 Check that the chimney flue...

Страница 6: ...ce 1 6 FIRE PLACE OPENING AND CHIMNEY CATCHMENT SPACE The front opening of the fire place must be between 350mm and 400mm wide and between 490 and 500mm high If the opening exceeds these dimensions th...

Страница 7: ...re 2 below for explanatory diagram Fig 2 1 7 FITTING TO FIREPLACES WITH EXISTING CHAIRBRICKS AND CONVENTIONAL BRICKBUILT CHIMNEYS This appliance is suitable for use in fireplaces fitted with an existi...

Страница 8: ...en tested for use in a pre cast flue block complying with BS EN 1858 In accordance with BS EN 1858 pre cast flues built with directly plastered faces front or rear are not correctly installed as to en...

Страница 9: ...s safety and in accordance with BS 5871 2 the fitting of a hearth panel or physical barrier should be carried out Should this advice not be followed however please give consideration to the safety of...

Страница 10: ...re is operated The following are important warnings relating to this spillage monitoring system 1 11 1 The spillage monitoring system must not be adjusted by the installer 1 11 2 The spillage monitori...

Страница 11: ...ys 175mm 7 inch diameter lined brick or stone flue insulated pre fabricated metal flue box to BS 715 BS EN 1856 2 or Pre Cast Flue to BS EN 1858 When installing into 125mm 5 inch diameter lined brick...

Страница 12: ...Hole in the Wall Installations Fig 5 Conventional Installations 12 Min 350mm Max 400mm Min 490mm Max 500mm As per section 1 6 1 8 or 1 9 Min 350mm Max 400mm Min 490mm Max 500mm 70mm Minimum This will...

Страница 13: ...packaging Remove the fuel bed set from the combustion chamber and store in a safe location Remove the firebox mounting plate from the rear face of the firebox assembly by unscrewing the 4 off M5 reta...

Страница 14: ...ff holes are provided in the mounting plate to allow a variety of fixing positions and secure the firebox mounting plate to the fireplace opening Use a minimum of eight fixing points to ensure a satis...

Страница 15: ...en lift the burner unit clear of the firebox Fig 8 2 3 8 With the burner removed from the firebox plan the routing of the gas supply pipe into the firebox See overpage section 2 3 9 for suggested pipe...

Страница 16: ...e to the isolating inlet elbow using 8mm rigid tubing There must be no soldered joints within the firebox See figure 9 10 below for suggested pipe layouts Fig 9 Fig 10 Note Before breaking into the ga...

Страница 17: ...the final gas connection thoroughly purge the gas supply pipework to remove all foreign matter otherwise serious damage may be caused to the gas control valve on the fire 2 4 GAS TIGHTNESS AND INLET P...

Страница 18: ...and front ceramic fibre pieces as shown below in figure 12 Fig 12 18 NOTE The position of the fuel bed components are critical to the performance of the product Therefore please ensure that the fuel b...

Страница 19: ...3 1 3 Place a single layer of bark chippings over the burner as shown below in figure 13 Fig 13 3 1 4 Fit the rear base log as shown below in figure 14 Fig 14 19 Rear log...

Страница 20: ...3 1 5 Fit log A as shown below in figure 15 onto the rear log Fig 15 3 1 6 Fit log B as shown below in figure 16 onto the rear log Fig 16 20 Log A Log B...

Страница 21: ...3 1 7 Fit log C as shown below in figure 17 onto the rear log Fig 17 3 1 8 Fit Log D as shown below in figure 18 using the cut out in Log C as a guide for placement Fig 18 21 Log C Log D...

Страница 22: ...ervicing we recommend that you use a HEPA filtered vacuum to remove any dust accumulated in and around the appliance before and after working on the appliance When replacing these articles we recommen...

Страница 23: ...igure 20 and secure with 2 off screws per side Ensure the top edge of the fascia has hooked over the top edge of the firebox Fig 20 3 2 2 Fit the draught diverter cover as supplied in the loose items...

Страница 24: ...main valve knob to the OFF position 3 3 5 Press and hold the STAR button and UP button on the remote hand set simultaneously see figure 22 overpage for image of handset 3 3 6 The valve will then emit...

Страница 25: ...n to the minimum level press the SMALL flame arrow on the handset twice If you wish to turn off the fire altogether press the STAR OFF button AFTER THE PILOT FLAME HAS BEEN EXTINGUISHED IF YOU WISH TO...

Страница 26: ...he fire has cooled 3 4 4 If spillage persists the flue is not functioning correctly and a fault exists If after investigation the fault cannot be traced and rectified the fire must be disconnected fro...

Страница 27: ...FITTING THE DRAUGHT DIVERTER COVER 3 5 1 The draught diverter cover plate is supplied in the loose items pack 3 5 2 Position in the glass fascia assembly as shown below in figure 24 Fig 24 27 Draught...

Страница 28: ...hen installing into 125mm 5 inch diameter lined brick or stone flue or insulated pre fabricated metal flue box to BS 715 BS EN 1856 2 and pre cast flues the restrictor baffle must not be fitted 3 5 2...

Страница 29: ...y 4 1 1 Prepare work area lay down dust sheets etc 4 1 2 Firstly remove the glass fascia assembly by removing the 2 off screws at the L H R H sides and then lift the glass fascia assembly clear see se...

Страница 30: ...etaining the pilot assembly Unscrew the thermocouple from the gas valve 4 3 4 Re assemble in reverse order Refit the fuel bed referring to section 3 1 for the correct layout The fascia can now be repl...

Страница 31: ...from BFM Europe Ltd who may be contacted at the address shown below Complete log set B 167640 Rear log B 167650 Log A B 167660 Log B B 167670 Log C B 167680 Log D B 167690 Log E B 167700 L H ceramic f...

Страница 32: ...of 150mm No purpose made additional ventilation is normally required for this appliance when installed in G B When installed I E please consult docu ment I S 813 1996 Domestic Gas Installation which i...

Страница 33: ...er and that during the service the fire is removed from the fire opening and the chimney or flue visually checked for fallen debris or blockages which must be removed The chimney should also be checke...

Страница 34: ...position 5 2 4 Switch the main valve knob to the OFF position 5 2 5 Press and hold the STAR button and UP button on the remote hand set simultaneously see figure 2 overpage for image of handset 5 2 6...

Страница 35: ...RE LIGHT THE APPLIANCE YOU MUST WAIT AT LEAST THREE MINUTES BEFORE TRYING TO RE LIGHT THE FIRE 5 3 SPILLAGE MONITORING SYSTEM This appliance is fitted with a spillage monitoring system which shuts dow...

Страница 36: ...4 1 Place the fuel bed front ceramic fibre as shown below in figure 1 Fig 1 5 4 2 Place the left hand and right hand front ceramic fibre pieces as shown below in figure 2 Fig 2 36 Front ceramic fibre...

Страница 37: ...5 4 3 Place a single layer of bark chippings over the burner as shown below in figure 3 Fig 3 5 4 4 Fit the rear base log as shown below in figure 4 Fig 4 37 Rear log...

Страница 38: ...5 4 5 Fit log A as shown below in figure 5 onto the rear log Fig 5 5 4 6 Fit log B as shown below in figure 6 onto the rear log Fig 6 38 Log A Log B...

Страница 39: ...5 4 7 Fit log C as shown below in figure 7 onto the rear log Fig 7 5 4 8 Fit Log D as shown below in figure 8 using the cut out in Log C as a guide for placement Fig 8 39 Log C Log D...

Страница 40: ...rvicing we recommend that you use a HEPA filtered vacuum to remove any dust accumulated in and around the appliance before and after working on the appliance When replacing these articles we recommend...

Страница 41: ...fascia as shown below in figure 10 and secure with 2 off screws per side Ensure the top edge of the fascia has hooked over the top edge of the firebox Fig 10 5 5 2 Fit the draught diverter cover as s...

Страница 42: ...rter cover plate can be removed for cleaning purposes or during routine removal replacement of the glass fasica assembly 5 6 2 Simply lift from the glass fascia assembly as shown below in figure 11 an...

Страница 43: ...mplete and genuine replacement set and the fire must never be run with the wrong number or damaged logs The fuel bed must be carefully re assembled as stated in section 5 4 To clean the glass panel pl...

Страница 44: ...rear cover of this book Complete log set B 167640 Rear log B 167650 Log A B 167660 Log B B 167670 Log C B 167680 Log D B 167690 Log E B 167700 L H ceramic front fibre B 160150 R H ceramic front fibre...

Отзывы: