background image

 Please keep this User Manual for future 

consultation.  If  you  sell  the  fixture  to 

another user, be sure that they also receive 
this instruction booklet.

 Unpack and check carefully there is no 

transportation damage before using the 

fixture.

 Before operating, ensure that the voltage 

and frequency of power supply match the 

power requirements of the fixture.

 It’s important to ground the yellow/green 

conductor to earth in order to avoid electric 
shock.

 Disconnect main power before servicing 

and maintenance.

 Use safety chain when fixes this fixture. 

Don’t handle the fixture by taking its head 

only, but always by taking its base.

 Maximum ambient temperature is: 400C

 

WARNING! 

The 

Moving Head 19x15W ZOOM

 has a powerful pan motor. The torque reaction 

when the head is panned suddenly can cause the base to move if the fixture is standing 

unsecured on a surface. Do not apply power to the 

Moving Head 19x15W ZOOM 

unless the 

baase is securely fastened to a surface or to rigging hardware.

WARNING! 

Use 2 clamps to rig the fixture. Do not hang the fixture from only one clamp. 

Lock each clamp with both 1/4-turn fasteners. Fasteners are locked only when turned a full 

900

 clockwise.

WARNING! 

When clamping the fixture to a truss or other structure at any other angle than 

with the yoke hanging vertically downwards, use two clamps of half-coupler type. Do not 

use any type of clamp that does not completely encircle the structure when fastened.

WARNING! 

Position or shade the head so that the front lens will not be exposed to sunlight 

or any other strong light source from any angle - even for a few seconds. 

See Figure 2.

 The 

Moving Head 19x15W ZOOM 

lens can focused the sun's rays, creating a potential fire hazard 

and causing damage.

IMPORTANT!

  Do  not  point  strong  light  output  from  other  fixtures  at  the 

Moving Head 

19x15W ZOOM

, as intense illumination can damaged the display.

Don’t operate it where the temperature is 
higher than this.

 In the event of serious operating problem, 

stop  using  the  fixture  immediately.  Never 

try to repair the fixture by yourself. Repairs 

carried out by unskilled people can lead to 
damage or malfunction. Please contact the 
nearest authorized technical assistance 
center. Always use the same type spare 
parts.

 Do not connect the device to any dimmer 

pack.

 Do not touch any wire during operation 

and there might be a hazard of electric 
shock.

 To prevent or reduce the risk of electrical 

shock or fire, do not expose the fixture to 

rain or moisture.

 The housing must be replaced if they are 

visibly damaged.

 Do not look directly at the LED light spot 

while the fixture is on.

2. SAFETY INFORMATION

1. INTRODUCTION

THANK YOU FOR PURCHASING 

Moving Head 19x15W ZOOM

. FOR SAFETY REASONS 

AND  TO  ENSURE  THE  TROUBLE-FREE  OPERATION,  CAREFULLY  READ  THE 

INSTRUCTIONS.

W A R N I N G !

User Manual 

Instrukcja Obsługi

Figure 2.

 Lenses can focused sunlight and strong light, presenting a risk of fire and damage to the fixture. 

 

Shield or shade the head if necessary.

Содержание P7100546

Страница 1: ...User Manual Instrukcja Obsługi P7100546 Moving Head 19x15 ZOOM 3 Sections ...

Страница 2: ...hat does not completely encircle the structure when fastened WARNING Position or shade the head so that the front lens will not be exposed to sunlight or any other strong light source from any angle even for a few seconds See Figure 2 The Moving Head 19x15W ZOOM lens can focused the sun s rays creating a potential fire hazard and causing damage IMPORTANT Do not point strong light output from other...

Страница 3: ... Power supply 100 245V AC 50 60Hz Power consumption 300W Net Weight 7 6 kg Weight with packaging 55 kg 4x Moving Heads Case Dimensions H 41 xW 32 xD 22 cm Dim case H 62 xW 80 xD 52 cm weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touc...

Страница 4: ...er or by a person with appropriate permissions Make sure that the power grid supply parameters are consistent with device parameters and limitations are not exceeded Using lamp the change rate of power voltage should be within 10 if the voltage is too high it will shorten the light s life if it s not enough the lamp will be dark Please restart it after turning off light for 20 minutes until full c...

Страница 5: ...ain The encoder Start using encoder optical coupling to judge the missing step and automatically correct the position Close the correct position without encoder decoupling X inversion Closed open Y inversion Closed open The operation mode The operation mode DMX voice control automatic Channel selection 16CH 24CH Display Settings Language selection Chinese English Pour screen Settings Shut down The...

Страница 6: ... Pan 2 Tilt 3 P T Speed 4 Dimmer 5 Red R group 1 6 Green G group 1 7 Blue B group 1 8 White W group 1 9 Shutter 10 Focus 11 Function mode 12 Functional mode speed 13 Pan Fine 14 Tilt Fine 15 Rest 255 16 Total useless 7 DMX CHANNELS 16 CH Mode Setting ...

Страница 7: ...up 1 9 Red R group 2 10 Green G group 2 11 Blue B group 2 12 White W group 2 13 Red R group 3 14 Green G group 3 15 Blue B group 3 16 White W group 3 17 Shutter 18 Focus 19 Function mode 20 Functional mode speed 21 Pan Fine 22 Tilt Fine 23 Rest 255 24 Total useless 24 CH Mode Moving Head 19x15W ZOOM Art No P7100546 ...

Страница 8: ...townicy lub innej konstrukcji pod innym kątem niż z jarzmem zwisającym pionowo w dół należy użyć dwóch zacisków typu Quick Half Coupler Hak Nie używaj zacisków które nie przylegają do konstrukcji po zamocowaniu UWAGA Ustaw lub przyciemnij Głowice aby przednia soczewka nie była narażona na działanie promieni słonecznych lub innych silnych źródeł światła pod dowolnym kątem nawet przez kilka sekund P...

Страница 9: ...wanym pomieszczeniu w odległości co najmniej 15cm od najbliższej powierzchni ściany sufitu itp Jednocześnie należy upewnić się że otwory wentylacyjne nie są zatkane oraz wentylatory działają poprawnie Po wyjęciu urządzenia z opakowania należy sprawdzić czy nie zostało ono uszkodzone podczas transportu Przed podłączeniem do sieci elektrycznej należy upewnić się że urządzenie zamocowane jest stabiln...

Страница 10: ...u zakończonego z jednej strony wtyczką sieci elektrycznej i wtyczką typu powerCON z drugiej strony w zestawie Urządzenie musi być obsługiwane przez UWAGA W przypadku uszkodzenia przewodu nie należy dokonywać samodzielnejnaprawy Wymianalubnaprawamożebyćwykonanajedynie w serwisie producenta lub przez osobę z odpowiednimi uprawnieniami wykwalifikowany personel techniczny Należy upewnić się że paramet...

Страница 11: ...status edycji wyjścia Koder Zacznij używać enkodera sprzężenie optyczne aby ocenić brakujący krok i automatycznie skoryguj pozycję Zamknąć prawidłową pozycję bez enkodera odsprzęganie X inwersja Zamknięte Otwarte Y inwersja Zamknięte Otwarte Tryb pracy Tryb pracy DMX voice control automatic Wybór programu 16CH 24CH Ustawienia wyświetlania Wybór języka Chinese English Ustawienia ekranu Zamknięcie K...

Страница 12: ...zybkość P T 4 Dimmer 5 Czerwony R grupa 1 6 Zielony G grupa 1 7 Niebieski B grupa 1 8 Biały W grupa 1 9 Shutter 10 Focus 11 Tryb funkcji 12 Prędkość trybu funkcjonalnego 13 Pan Fine 14 Tilt Fine 15 Rest 255 16 Razem bezużyteczne 7 KANAŁY DMX Tryb 16 CH Ustawienia ...

Страница 13: ...rwony R grupa 2 10 Zielony G grupa 2 11 Niebieski B grupa 2 12 Biały W grupa 2 13 Czerwony R grupa 3 14 Zielony G grupa 3 15 Niebieski B grupa 3 16 Biały W grupa 3 17 Shutter 18 Focus 19 Tryb funkcji 20 Prędkość trybu funkcjonalnego 21 Pan Fine 22 Tilt Fine 23 Rest 255 24 Razem bezużyteczne Tryb 24 CH Moving Head 19x15W ZOOM Art No P7100546 ...

Страница 14: ...User Manual Instrukcja Obsługi ...

Страница 15: ...Moving Head 19x15W ZOOM Art No P7100546 ...

Страница 16: ...www flash butrym pl F7100546 ...

Отзывы: