background image

Marker Installation for the FTS 371 Vanguard

®

4.

 

Carefully place the wires inside the marker 

base and close the access plate. Ensure the 

screws and the cord grip are tight to 

prevent moisture intrusion.

1.

 

Open the access plate by loosening the (2) 

captive screws enough to swing the cover 

open and remove the installed wire nuts.

2.

 

Feed the marker cable through the black 

cord grip and strip approximately 1/4” from 

the jacket of each conductor. Cut off the 

the bare drain wire as this will not be used 

in the marker base.

3.

 

Using the supplied wire nuts and electrical 

tape connect the (2) Red wires together, 

the (2) Black wires together, and the (2) 

White\Blue wires together..

The following guide provides installation steps for the LED marker provided with the FTS 371 

Vanguard Red only system. Verify the provided marker cable has a RED, BLACK, WHITE/BLUE 

and bare DRAIN wire. 