FTS 350i-2 USER MANUAL
Flash Technology, LLC
Revision A – 4/21/2022
10
Note: All dimensions are in inches (millimeters).
Figure 2-2 – Mounting Outline with Adapter Bracket
2.3 WIRING THE BEACON POWER AND MONITORING CONNECTIONS
The beacon is supplied with a 50-foot length of power & alarm cable pre-wired to the internal electronics to
facilitate installation (see
, page 10). The only connections required are power (100-240 VAC, 50/60 Hz)
and ground. The ground wire must be connected for proper operation and protection of the beacon. Optional 75-
foot, 100-foot and custom cables lengths are available.
Optional dry contact monitoring connections permit monitoring of lighting system operation. The contact is closed
when the beacon is operating normally and no fault is detected.
Table 2-1 – Standard Power & Alarm Connections
5 C
o
n
d
u
cto
r C
ab
le
Wire Color Function
Beacon Wiring Connections External Connections
Black
Input Power
X1
(120 VAC) - Line
(240 VAC) - L1
White
Input Power
(120 VAC) - Neutral
(240 VAC) – L2
Green
Ground
Ground
Red
Alarm Contact
X2
Alarm Input
2
Orange
Alarm Contact
Alarm Input
2
2
Refer to the monitoring system manufacturer’s installation manual for connection locations