Flash butrym STROBO 1000W Скачать руководство пользователя страница 3

www.flash-butrym.pl 

Strona 3 

 

INSTALLATION INSTRUCTIONS 

a)  Installing or replacing the lamps 

Before replacing the lamps let the lamps cool down, because during operation, the lamps can reach 
temperatures of up to 700

. Wait at least 10 minutes after use before opening the housing. 

During the installation of the lamp do not touch the glass bulb bare handed. Always use a cloth to 
handle the lamp during insertion and removal. 
Do not install lamps with a higher wattage. They generate higher temperatures than for which the 
device was designed for. 
For the installation, you need a 750W strobe lamp. 

 

 
 
Procedure:   

1)  Unscrew the screw 
2) 

Carefully remove the glass pane, making sure it doesn’t get damaged 

3)  Remove the old lamp carefully 
4)  Place the new lamp 
5)  Close the glass pane 
6)  Fasten the screw 

CAUTION:    1. 

Do not operate this device with open cover! 

                        2. The glass pane has to be replaced when it is damaged! 

3. The lamp has to be replaced when it is damaged or deformed! 

    4.

 Only install the lamp with the device unplugged from the mains!

 

b)    Replacing the fuse

 

If the lamp burns out, chances are the internal fuse might too. Only replace the fuse with a fuse of 
the same type and rating (see technical specifications at the end of this user manual). 
Since  the  fuse  for  this  device  is  an  internal  fuse,  it  should  only  be  replaced  by  your  agent  or  an 
authorized dealer. 

CAUTION:   

Only replace the fuse with the device unplugged from the mains!

 

c)    Mounting the device

 

The installation must  always be secured with a secondary safety attachment, e.g. an appropriate 
safety cable. 
Never stand directly below the device when mounting, removing or servicing the device. 

Procedure:

 

The  stroboscope  should  be  installed  outside  areas  where  persons  may  reach  it,  walk  by  or  be 
seated. 
Overhead  mounting  requires  extensive  experience,  including  amongst  others  calculating  working 
load limits, installation material being used, and periodic safety inspection of all installation material 
and  the  device.  If  you  lack  these  qualifications,  do  not  attempt  the  installation  yourself.  Improper 
installation can result in bodily injury. 
Before mounting make sure that the installation area can hold a minimum point load of 10 times the 
device s weight. 

CAUTION:   

When  installing  the  device,  make  sure  there  is  no  highly  inflammable 

material within a distance of min. 0.5m! 

CLEANING AND MAINTENANCE 

The following points have to be considered during the inspection: 
1) All screws for installing the devices or parts of the device have to be tightly connected and must 
not be corroded. 
2)  There must not be any deformations on the housing, glass pane, fixations and installation spots. 
3)  The  electric  power  supply  cables  must  not  show  any  damage,  material  fatigue  or  sediments. 