DISCONNECT POWER BEFORE REMOVING THE GUARDS FOR ANY REASON
6
Knock Down Cylinder Position
The previously mentioned laser switch, sends a signal to the PLC, and when turn
the hemmed quadrant, the cylinder shown below will activate, knocking down the
front corner of the quadrant. This directs the metal into the idler rolls. Using
standard notches for HVAC, this cylinder is positioned 2 5/8” from the machine
plate to the center line of the cylinder. See Below:
Dependent on the notch type, this switch may need to be moved inward or
outward.