FIRMWARE UPDATE
You can easily update the firmware with a MIDI sysex dump. To do so, use a MIDI-sysex-dump-
loader for example the freeware MIDI-OX or Electron C6 (win or mac).
1. Load the firmware sysex file to your computer.
2. Connect the MIDI interface of the computer with the MIDI input of the modul
(jack REC-1/MIDI). Therefore you have to use the provided MIDI adapter accessory.
3. Hold down both keys LINK and STOP while you power on the module.
The key LINK is blinking red.
4. Now send the Sysex firmware file to the module. While the update runs you can see the
progress indicator (green PLAY LED’s and red REC LED’s bar). The upload during time is
for instance 1,5 minutes.
5. If no error message is displayed the update is succesfull finished.
The module reboots automatically
ERROR CODES
PLAY 1 LED blinking green
Wrong SysexID
PLAY 1 LED blinking red
Packet Checksum Error
PLAY 2 LED blinking green
Firmware Checksum Error
PLAY 2 LED blinking red
Flash Error
PLAY 3 LED blinking green
Timeout
PLAY 3 LED blinking red
Interface Check Failed
ADVICE:
Sometimes it’s necessary to set the parameter “Delay” or “Timeout” to higher values (such as
80ms) from your used dumploader software.
18
Содержание QUAD CV RECORDER
Страница 1: ...QUAD CV RECORDER MANUAL Version 1 00 FLAME...