As an alternative to the LEARN function, the module can also be programmed via SYSEX.
Some SYSEX files are available for this. These can be loaded with a MIDI SYSEX dump pro-
gram (e.g. MIDI-OX or Elektron C6) from a computer via MIDI. After receiving the SYSEX file,
the data is saved permanently.
NOTE:
When the SYSEX data is received, the LEARN LED lights up permanently and goes out when
reception is successful. If the SYSEX reception was faulty, the LED flashes several times in
quick succession, it is then not saved and the old data are retained. The reception can also be
canceled with the LEARN key.
DETAILS:
There are three types of files:
Type 1: change all data
Type 2: set midi channel and control change number from the MODULATION output
Type 3: set midi channel from the PITCHBEND output
You can download some ready-made SYSEX files from the FLAME website.
You can also create your own SYSEX files (for example with the freeware program MIDI-OX).
An overview and documentation of the implemented SYSEX data formats can be found in the
next chapter.
3.5 Settings via SYSEX files
9