Notes:
Speed inverter is pre-set for optimum air flow/temperature rise.
Based on kW selection, blower will adjust speed. See Chart below
HEAT SETTING
BTUH
CFM
TEMP. RISE
NOISE RATING
60 kW
205,000
3300
110DEG F/43DEG C
67 DB
40 kW
164,000
2800
85DEG F/30DEG C
63 DB
20kW
82,000
2450
50DEG F/10DEG C
63DB
FAN ONLY
3900
71DB
SHUTDOWN
1
Move all heater setting controls to the "OFF" position
2
Leave Fan in the "ON" position for 3-5 minutes
3
Turn Fan OFF
( blower is preset to run for 30 seconds before coming to a complete stop)
4
Push Master button "IN"
5
Shut off all power source
6
Disconnect all power sources
7
Store heater