START UP INSTRUCTIONS
1
Determine power source - 575V (confirm power source is correct)
2
Remove top cover and inspect all wiring
(once complete, secure top cover to heater using the same hardware)
3
Connect Flanged Camlocks to female camlocks ( colour coded)
Connect camlocks as follows:
Red
A
Black
B
Blue
C
Ground
G
3 PHASE UNIT CONNECTION
4
Turn on power supply
5
Pull "Master" button to the out position
6
Determine "Manual" or Remote Thermostat (if remote, set desired temperature)
7
Turn Blower on/off switch to the "ON" position
(The blower will start and the green air flow light will come on)
8
Turn on heater settings as desired
( 150kW= 60kW & 90kW combined)
Failure to have proper air flow will cause unit to overheat and shut down
The green light should come on and air should be pushed through the outlet port
Check to see that only the green light is on.
Caution: Heater body panels will get very hot