FKI GL 9000 Series Скачать руководство пользователя страница 21

21 

 

8.

  End of use 

8.1.

 

Destruction 

 

 
The contact grill is marked with the above recycling symbol. (EC Directive 2002/96/EC) and must 
be disposed of in accordance with your country order. 
 
This means that when the product becomes obsolete, you should dispose of it after the local mu-
nicipality’s rules, for example in unsorted waste stream.  
 
 
 

9.

  Annex 

9.1.

 

Labels, symbols and pictograms 

 
The hamburger machine is marked with the following symbols and pictograms: 

 
 
Recycling symbol in accordance to EC (see part 6) 
 
 
 

Hot surface – use gloves.  
 
 
 
 

Содержание GL 9000 Series

Страница 1: ...Users Manual Turbomatic contact grill GL 9000 series Version 2 4 SEP 2016...

Страница 2: ...2...

Страница 3: ...ersonal safety equipment 6 4 2 Residual risks 6 5 Operation 7 5 1 Quick guide 7 5 2 Programming 7 5 3 Locking display 8 5 4 Operating 9 5 5 Stop 9 5 6 Emergency stop 9 5 6 1 Restart efter emergency st...

Страница 4: ...Knowledge It is the employer s owner of the contact grill obligation to ensure that all who serve main tain or repair the contact grill read the instructions at least those parts of it that are relev...

Страница 5: ...fications and consumption Dimensions GL 9001 GL 9002 GL 9003 GL 9010 Dimension W x D x H mm 400 x 630 x 480 600 x 630 x 480 400 x 630 x 480 490 x 730 x 480 Weight 62 kg 85 kg 65 kg 95 kg Note the heig...

Страница 6: ...contact grill must be placed under hoods or other suction of cooking smells 4 Safety and residual risks 4 1 Safety precautions to be taken by the user 4 1 1 Personal safety equipment It is recommended...

Страница 7: ...l pro grammed Place the meat on the bottom pan and press one of the program buttons 1 3 The upper will close and the meat will fry on both sides in the pre set time as the display counts down to 0 aft...

Страница 8: ...enu press Reset Factory settings Standby temp 240 C Normal temp upper pan 250 C Normal temp lower pan 240 C Program 1 130 sec Program 2 130 sec Program 3 130 sec 5 3 Locking display The display shows...

Страница 9: ...ower to the contact grill turn the main switch on the back side to OFF 5 6 Emergency stop The upper pan can be stopped during movement by turning the main switch to OFF 5 6 1 Restart efter emergency s...

Страница 10: ...See the technical data section 3 4 In particular if the counter top is hanging on the wall be aware that this is firmly attached and that the wall is suitable for fixing of heavy loads Note that there...

Страница 11: ...blank Wipe dry with clean cloth or paper If Teflon sheet is used in the pans clean them with a damp cloth with a mild cleaning agent We recommend using Teflon sheet supplied as it prevents burn in and...

Страница 12: ...k the fuse on the PCB Still no light in one display other is OK Try to connect a new keypad to check if it s the keyboard that is defec tive The plug must be installed correctly on the PCB the shiny s...

Страница 13: ...13 7 3 1 Specifications on spare parts GL 9001...

Страница 14: ...4 1 kW 400V 8 83 10323 1 Frontpanel incl PCB and key pad 9 83 20103 1 Electrical components see wiring diagram 10 83 09975 1 Bottom plate GL 9001 3 11 82 06510 4 Leg M8 adjustable 12 83 09980 1 Fat dr...

Страница 15: ...ption 1 83 10292 1 Bottom cabinet GL 9002 2 83 10293 1 Pan GL 9002 lower 3 83 10237 1 Top cabinet large incl arm 4 83 10279 1 Pan upper large 5 83 10325 1 Top cabinet small incl arm 6 83 10324 1 Front...

Страница 16: ...400V 15 83 09323 1 Heatelement upper 2 3 kW 400V 16 82 06510 4 Leg M8 adjustable 17 84 00067 1 Switch 4 polet CA 25 32A 400V 17a 84 00292 1 Handle for switch type CA 18 84 00290 1 Fuse holder 18a 84 0...

Страница 17: ...17 GL 9003...

Страница 18: ...Pan GL 9003 lower 8 83 09320 2 Pan upper small 9 83 09321 2 Heat element upper 2 3 kW 400V 10 83 09323 2 Heat element lower 2 6 kW 400V 11 82 06510 4 Leg M8 adjustable 12 84 00067 1 Switch 4 polet CA...

Страница 19: ...19 GL 9010...

Страница 20: ...mponents see wiring diagram 10 83 10323 1 Frontpanel incl PCB and key pad 11 83 10333 6 Heat element 1 85 kW 400V 12 83 10325 1 Actuator LA 23 13 83 10096 1 Adjustingbolt for pan 14 83 10336 4 Tension...

Страница 21: ...h your country order This means that when the product becomes obsolete you should dispose of it after the local mu nicipality s rules for example in unsorted waste stream 9 Annex 9 1 Labels symbols an...

Страница 22: ...tnr og by 5690 Tommerup Erkl rer hermed at maskine type Turbomatic GL 9001 GL 9002 GL 9003 og GL 9010 Er fremstillet i overensstemmelse med f lgende EF direktiver 2006 42 EF Maskindirektivet under anv...

Страница 23: ...23 9 4 Wirering diagrams GL 9001 400V Print 1 Udgangssignal aktuator 2 Indgang 24VDC 3 Indgang 24VDC 4 Udgangssignal varmelegeme nedre 5 Udgangssignal varmelegeme vre 6 Indgang 24VDC M...

Страница 24: ...SSR 20 265A 6 83 07563 1 Rectifyer 7 84 00294 1 Ringtransformer 230V 2x24V 80VA 8 83 10022 1 Actuator MLA 2 9 83 09322 1 Heat element lower 4 7 kW 400V 10 83 09320 1 Heat element upper 4 1 kW 400V 11...

Страница 25: ...25 GL 9002 400V M Print 1 Udgangssignal aktuator 2 Indgang 24VDC 3 Indgang 24VDC 4 Udgangssignal varmelegeme nedre 5 Udgangssignal varmelegeme vre 6 Indgang 24VDC M...

Страница 26: ...1 Ringtransformer 230V 2x24V 80VA 8 83 10022 2 Actuator MLA 2 9 83 09322 1 Heat element lower 4 7 kW 400V 10 83 09320 1 Heat element upper 4 1 kW 400V 11 83 09057 1 Sensor PT100 upper 11a 83 09998 1...

Страница 27: ...27 GL 9003 400V M Print 1 Udgangssignal aktuator 2 Indgang 24VDC 3 Indgang 24VDC 4 Udgangssignal varmelegeme nedre 5 Udgangssignal varmelegeme vre 6 Indgang 24VDC M...

Страница 28: ...SSR 20 265A 6 83 07563 1 Rectifyer 7 84 00295 1 Ringtransformer 230V 2x24V 80VA 8 83 10022 2 Actuator MLA 2 9 83 09323 1 Heat element lower 2 6 kW 400V 10 83 09321 1 Heat element upper 2 3 kW 400V 11...

Страница 29: ...29 GL 9010 400V Print 1 Udgangssignal aktuator 2 Indgang 24VDC 3 Indgang 24VDC 4 Udgangssignal varmelegeme nedre 5 Udgangssignal varmelegeme vre 6 Indgang 24VDC M...

Страница 30: ...7 84 00294 1 Ringtransformer 230V 2x24V 80VA 8 83 10022 1 Actuator MLA 2 9 83 09322 6 Heat element 1 85 kW 400V 10 83 30015 1 Connection block 15 pole 11 83 09057 1 Sensor PT100 upper 11a 83 09998 1...

Страница 31: ...31 Bygh jvej 5 Verninge DK 5690 Tommerup Danmark Tlf 45 6475 1066 info fki dk www fki dk...

Отзывы: