background image

Five9 Network Systems LLC. 

 

 

 

 T3105K1 Installation Manual 

Document # 000003, Rev 6, 05/06/2014 

Page 7 

 

3.6.2 Power Switches 

 

The T3105K1 has 3 power switches: a System Power Switch and a System Reset  

 

 

Switch in the front as well as a general On/Off switch on the power supply from  

 

 

the back. The following diagram shows the front power switches (bottom right) 

 

 

The System reset switch will soft reset the system; the PSU will not cycle    

 

 

the power ON / OFF. 

 

The System power switch will power ON / OFF the system power supply    

 

 

according to Motherboard BIOS setting, (if you press power switch over 4  

 

 

seconds the system will power off) 

 

The power switch on the back is a general On/Off switch providing the ability to  

 

 

hard turn off the system 

3.7 

Post-Installation Test 

Once the T3105K1 is properly installed, turn the system on and verify using a 

monitor that the motherboard is booting up. To test with Solaris 10, use the 

following guidelines: 

Power On 

Indicator 

HDD Activity 

System Reset 

Switch 

System Power 

Switch 

Содержание T3105K1

Страница 1: ...rsions 2014 Five9 Network Systems LLC 300 Main Street Suite 12A East Rochester NY 14445 USA All rights reserved This product or document is protected by copyright and distributed under licenses restricting its use copying distribution and decompilation No part of this product or document may be reproduced in any form by any means without prior written authorization of Five9NS and its licensors if ...

Страница 2: ...ose of the Equipment 3 2 0 Application 3 2 1 Introduction 3 3 0 Installation 4 3 1 Prior to Installation 4 3 2 Unpacking and Inspection 5 3 3 Cautions and Warnings 5 3 4 Wiring 6 3 5 Physical Characteristics 6 3 6 Electrical Characteristics 6 3 7 Post Installation Test 7 4 0 Safety Information 4 1 Typical Application 9 4 2 Cautions and Warnings 9 5 0 Sicherheit German Safety Provisions 10 ...

Страница 3: ... which are carried as a part of the Intel Embedded IA Extended Life Cycle Support In the recommended installation the unit receives power from an AC power source and is placed in a cabinet in a workstation like position 1 2 2 It supports Solaris which is the most scalable and secure operating system With Solaris the T3105K1 server provides fast performance near continual uptime and the security an...

Страница 4: ...wing installation instructions should be followed A Elevated Operating Ambient If installed in a closed assembly the operating ambient temperature of the assembly environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer B Reduced Air Flow Insta...

Страница 5: ...rsonnel who are knowledgeable on the procedures and hazards associated with this product G Cautions and Warnings All caution and warning instructions noted on the product and in the manual should be followed see Section 3 3 below for details 3 2 Unpacking and Inspection 3 2 1 Carefully open the packaging and remove the T3105K1 Verify that all components have been included in the package per the pa...

Страница 6: ... routing of external cables should be carefully studied and planned before attempting installation of the equipment Allow adequate space for installation of cable and connectors Avoid sharp bends 3 5 Physical Characteristics 3 5 1 The T3105K1 shall be located away from heat sources magnetic fields and areas with excessive dust 3 5 2 When sitting on a table top avoid uneven or unstable work surface...

Страница 7: ...tem the PSU will not cycle the power ON OFF The System power switch will power ON OFF the system power supply according to Motherboard BIOS setting if you press power switch over 4 seconds the system will power off The power switch on the back is a general On Off switch providing the ability to hard turn off the system 3 7 Post Installation Test Once the T3105K1 is properly installed turn the syst...

Страница 8: ...command line option and enter the following commands vts_cmd list_tests This command lists all the tests to be performed Make sure all test are enabled To enable a certain test use the following vts_cmd enable_test testname vts_cmd set_global_options Duration of Testing 60 Verbose Enable This will run the tests for 60 minutes vts_cmd start This will start the testing You can stop the tests anytime...

Страница 9: ...ndicator to be used only for starting a printing job 4 1 1 This product is not intended for use in the immediate direct visual field of the display work place To avoid disturbing reflections on the display work place this product shall not be placed in the immediate direct field of vision 4 1 2 The unit is only for use in IT server rooms production floors and other restricted access locations away...

Страница 10: ...ionshallen und anderen Orten mit eingeschränktem Zugang abseits der allgemeinen Arbeitsplatzumgebung gedacht 5 1 3 Gehen Sie wie folgt vor um das Gerat für die Verwendung einzurichten A Erhöhte Betriebsumgebungstemperatur Wenn das Gerät in einer geschlossenen Baugruppe installiert ist kann die Betriebsumgebungstemperatur der Montageumgebung größer sein als die Raumtemperatur Deshalb sollte bei der...

Страница 11: ...ten Sie bei der Verwendung von Verlängerunskabeln oder Steckerleisten die Einhaltung der elektrischen Spezifikationen F System Wartung Versuchen Sie nicht die Wartung Ihres Geräts selbst durchzuführen Wartung und Pflege des Produktes ist nur durch geschultes Servicepersonal das Wissen über die Verfahren und Gefahren die mit diesem Produkt verbunden sind besitzt auszuführen G Vorsichtshinweise und ...

Страница 12: ...en Akkus besteht Feuer oder Explosionsgefahr Ersetzen Sie den Akku nur durch denselben oder einen gleichwertigen vom Hersteller empfohlenen Typ und befolgen Sie sorgfältig die Installationsanweisungenen Entsorgen Sie verbrauchte Akkus ordnungsgemäß 5 2 Vorsicht 5 2 1 Warnung Bei Arbeiten im Inneren des Servers aufgrund der exponierten Art der Systemlüfter ist Vorsicht geboten ...

Отзывы: