SERVICE 

Adjusting High Voltage Output

 

In case of excessive arcing on a clean, dry Cell, there is 
an adjustable resistor mounted on the Power Board. 
 
1.  Turn off the system switch before opening the unit. 
 
2.  Remove  the  cover  by  slipping  the  "S"  hook  from  the 

chain and letting the cover gently down. 

 
3.  Lift the cover up off the rear hinge. 
 
4.  Remove the power box cover. 
 
5.  With  a  small  slot  screwdriver,  adjust  "R-2"  slightly 

clockwise to reduce voltage to the cell.  Do not reduce 
the  voltage  too  much  or  the  efficiency  of  the  air 
cleaner will be reduced. 

Removing The Power Box

 

1.  Shut off main breaker or switch. 
 
2.  Remove the cover as described previously. 
 
3.  Open power box cover. 
 
4.  Disconnect the following wires: 
 

Terminal Block  -Red, blue or yellow, black and 
 

 

 white leads from motor 

 

 

-Supply line leads 

 

  Power Board 

-Orange or grey leads on 

 

 

 

 

 HV1 and HV2 

 

5.  Remove  the  two  nuts  holding  the  power  box  to  the 

cell section. 

 
 
 

TECHNICAL DATA 

TROUBLESHOOTING GUIDE

 

  PROBLEM: 

  CHECK: 

Unit Does Not 
Operate 

1.  Main breaker is 

ON

 or voltage 

is supplied to unit. 

2.  Main supply fuse or breaker is 

not tripped. 

3.  Unit cover is completely closed 

and locked into place. 

4.  Power switch is 

ON

Performance 
Indicator Light Is Not 
Lit 

1.  System switch is 

ON

2.  Remove Cells, close access 

door and turn unit 

ON

.  If 

Performance Indicator is still 
off, problem is in the power 
box.   If light comes on with no 
cells, then there is a short 
circuit in the cells.  Place one 
cell in the unit, close access 
door and turn unit 

ON

.  If the 

light comes on, check the other 
cell by the same method.  
When it has been determined 
which cell is the problem, look 
for bent plates, broken ionizing 
wires or burnt insulators or if 
cell is completely dry after 
washing. 

Performance 
Indicator Light Is Lit, 
Fan Not Working 

1.  Fan control switch is in proper 

position. 

2.  Motor leads are connected to 

terminal block. 

Cells Arcing 
Excessively 

1.  Cells are completely dry after 

washing. 

2.  Cell plates are not bent or 

spaced too close. 

3.  Cell insulators are not cracked, 

broken or burnt. 

4.  Cell is dirty and needs cleaning. 
5.  Broken ionizing wires. 

Dimensions 

Length 

29.5 in 

75.0 cm 

 

Width 

27.0 in 

68.6 cm 

 

Height 

14.5 in 

37.0 cm 

Weight 

 

95.0 lbs 

43.0 kg 

Input Voltage   

120 V   60 Hz 

 

 

 

220 V   60 Hz 

 

 

 

220-240 V  50 Hz 

 

Power 
Consumption 

 
(max) 

350 Watts 

 

Air Flow 

High 

1300 CFM 

2210 m

3

/hr 

 

Medium 

1050 CFM 

1785 m

3

/hr 

 

Low 

  750 CFM 

1275 m

3

/hr 

Motor 

 

   1/12 HP 

 

Содержание SSCB15

Страница 1: ...Operation And Maintenance Manual MODEL SSCB15 CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE OPERATING UNIT ...

Страница 2: ...ld spores fungi bacteria viruses and more down to 0 01 micron 0 01 micron 1 2 540 000 of an inch BENEFITS Helps clear up a smokey environment quickly so customers can dine more comfortably Helps employees reduce suffering from irritated eyes nasal congestion and respiratory problems that lead to absenteeism Helps prevent damaging black and greasy particles from staining ceilings walls and furnishi...

Страница 3: ...TALLATION 1 Read instructions carefully Failure to do so may result in product damage or injury 2 Make sure the sizing is correct for your application 3 Installation should be done by a knowledgeable technician 4 After installation check out operation as provided in these instructions Mounting 1 Remove the unit from the box with packing still on the unit and lay it on its back grill side up 2 Rele...

Страница 4: ...otine remains on plates let Cells soak in hot soapy water for 30 minutes Never use any instrument to clean the cell as this may damage the ionizing wires or bend cell plates 5 Spray Prefilters with DAX Detergent and rinse well 6 To dry cells tilt on 45º angle against wall with arrows pointing sideways Allow to dry completely for 10 24 hours Place in sunlight for faster drying time 7 When the Cells...

Страница 5: ...3 Unit cover is completely closed and locked into place 4 Power switch is ON Performance Indicator Light Is Not Lit 1 System switch is ON 2 Remove Cells close access door and turn unit ON If Performance Indicator is still off problem is in the power box If light comes on with no cells then there is a short circuit in the cells Place one cell in the unit close access door and turn unit ON If the li...

Страница 6: ...Electrical Schematic B with Wired Remote 120 Volt Electrical Schematic A 120 Volt ...

Страница 7: ...Electrical Schematic B with Wired Remote 220 240 Volt Electrical Schematic A 220 240 Volt ...

Страница 8: ...s a consequence of any misapplication negligent handling improper servicing unauthorized alteration or improper operations 4 Failure to start due to voltage conditions blown fuses open circuit breakers or other damages due to the inadequacy or interruption of electrical service 5 Damage as a result of floods winds fires lightning accidents corrosive atmosphere or other conditions beyond the contro...

Отзывы: