background image

Blower  and  motor  are 
hidden  above  ceiling 
tiles 

for 

space 

c o n s e r v a t i o n .  
Advantageous  for  low 
ceiling 

applications 

where  a  larger  unit 
would be obstructive. 
 
 
Hinged cover provides 
convenient  access  to 
g r i l l ,  

p r e f i l t e r , 

collecting  cell  and 
e l e c t r i c a l 
compartment.    Safety 
interlock  cuts  power 
wh e n  

c o ve r  

i s 

opened. 
 
 
Rear  hinges  permit 
smooth  release  of 
cover 

for 

easy 

installation. 
 
 
Removable intake grill 
for easy cleaning.

 

Heavy  duty  collecting 
cell  captures  airborne 
pollutants  and  simply 
washes clean. 
 
 
 
Washable,  aluminum 
mesh prefilter catches 
lint and large particles 
before 

they 

enter 

collecting cell. 
 
 
 
3-speed  fan  control 
allows  adjustment  of 
air flow to activity level 
in room. 

MAJOR COMPONENTS 

The Electronic Air Cleaner is approximately  24 x 28  x 
15 in (61 x 71 x 38 cm) with 6 in (15.2 cm) of the unit 
above  the  ceiling.    The  cover  and  exhaust  grill  which 
remain below the ceiling are hinged to allow access to 
the cell and power board.  The unit is rated at 700 CFM 
(1190 m

3

/hr) on the highest speed setting. 

 

CABINET

 

The  cabinet  is  constructed  of  20  gauge  steel.    The 
external  parts  have  a  tough  powder-coated,  scratch-
resistant  finish.    Access  to  the  collecting  cell,  power 
box  and  prefilter  is  made  by  releasing  the  latches  of 
the cover and allowing it to swing down. 
 
The cover is interlocked to cut power to the unit when 
opened. 
 

PREFILTER

 

The washable prefilter measuring 12.5 x 20 in (31.75 x 
50.8  cm)  is  constructed  of  multi-layers  of  aluminum 
mesh for maximum filtration of large particles. 
 

COLLECTING CELL

 

The dual voltage collecting cell is constructed of heavy 
gauge  aluminum  to  resist  rust  and  damage.    The  first 
stage, the ionizing section, is charged at approximately 
7500  VDC.    The  collecting  plates  are  alternately 
grounded and charged at 5000 VDC.  The arrow on the 
cells indicates the direction of air flow which must point 
up towards the fan motor. 
 

MOTOR AND FAN BLADE

 

The motor is 1/33 HP, 1050 RPM, 3-speed, controlled 
by  a  3-position  slide  switch.    The  motor  is  thermally 
protected.  The fan blade is 14 in (35.5 cm) with a 20

o

 

pitch. 
 

ELECTRICAL COMPARTMENT

 

The removable power box contains the speed control, 
system  switch,  high  voltage  power  board,  and 
performance indicator light. 

The interlock switch is located in the cabinet body 
near the wiring compartment. 

INSTALLATION 

1.  Read  instructions  carefully.    Failure  to  do  so  may 

result in product damage or injury. 

2.  Make sure the sizing is correct for your application. 
3.  Installation  should  be  done  by  a  knowledgeable 

technician. 

4.  After installation, check out operation as provided 

in these instructions. 

MOUNTING 

1.  Remove the unit from the  box and  lay the  unit  on 

its back, grill side up. 

2.  Release  the  grill  by  pushing  the  levers,  located  in 

the exhaust grill, toward each other and lift up. 

4.  Remove the „S‟ hook from each chain, tilt cover up 

until  the  cover  releases  from  the  back 
hinges.installation easier.   The fan blade may also 
be removed.  Refer to “Removing The Power Box” 
instructions on the last page of this manual. 

5.  Holes are provided in the cabinet to accommodate 

5/16  in    (8  mm)  threaded  rod.    Threaded  rod  can 
be attached to the angle iron which is  laid across 
the joists, by drilling holes through these supports.  
Pass  threaded  rod  up  through  the  supports  and 
secure with two nuts and washers.  This will allow 
adjustment  of  the  unit  so  that  the  flange  is  flush 
with the underside of the ceiling. 

Leave enough room around the Air Cleaner for 
removal of collecting cell and prefilter. 

6.  Replace cell section, wiring and chain. 

Содержание SSC-7

Страница 1: ...Operation And Maintenance Manual MODEL SSC 7 SEMI FLUSH CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE OPERATING UNIT ...

Страница 2: ...gi bacteria viruses and more down to 0 01 micron 0 01 micron 1 2 540 000 of an inch BENEFITS Helps clear up a smokey environment quickly so customers can dine more comfortably Helps employees reduce suffering from irritated eyes nasal congestion and respiratory problems that lead to absenteeism Helps prevent damaging black and greasy particles from staining ceilings walls and furnishings reducing ...

Страница 3: ...e ionizing section is charged at approximately 7500 VDC The collecting plates are alternately grounded and charged at 5000 VDC The arrow on the cells indicates the direction of air flow which must point up towards the fan motor MOTOR AND FAN BLADE The motor is 1 33 HP 1050 RPM 3 speed controlled by a 3 position slide switch The motor is thermally protected The fan blade is 14 in 35 5 cm with a 20o...

Страница 4: ...ell well with hot water 120ºF 49ºC maximum 5 If dirt or nicotine remains on plates let cell soak in hot soapy water for 30 minutes Never use any instrument to clean the cell as this may damage the ionizing wires or misalign cell plates 6 Spray prefilter with DAX Detergent and rinse well 7 To dry cell tilt on 45º angle against wall with arrow pointing sideways Allow to dry completely for at least 8...

Страница 5: ...ker is ON or voltage is supplied to unit 2 Main supply fuse or breaker is not tripped 3 Unit cover is completely closed and locked into place 4 System switch is ON Performance Indicator Light OFF 1 System switch is ON 2 Remove cell close access door and turn unit ON If Performance Indicator is still off problem is in the power box If light comes on with no cell then there is a short circuit in the...

Страница 6: ...Electrical Schematic A 120 Volt Electrical Schematic B with Wireless Remote 120 Volt ...

Страница 7: ...Electrical Schematic A 220 240 Volt Electrical Schematic B with Wireless Remote 220 240 Volt ...

Страница 8: ...a consequence of any misapplication negligent handling improper servicing unauthorized alteration or improper operations 4 Failure to start due to voltage conditions blown fuses open circuit breakers or other damages due to the inadequacy or interruption of electrical service 5 Damage as a result of floods winds fires lightning accidents corrosive atmosphere or other conditions beyond the control ...

Отзывы: