background image

Operation And Maintenance Manual 

 

MODEL SSC-7 

SEMI-FLUSH CEILING MOUNTED 

ELECTRONIC AIR CLEANER 

 

IMPORTANT:  PLEASE READ MANUAL BEFORE OPERATING UNIT 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание SSC-7

Страница 1: ...Operation And Maintenance Manual MODEL SSC 7 SEMI FLUSH CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE OPERATING UNIT ...

Страница 2: ...gi bacteria viruses and more down to 0 01 micron 0 01 micron 1 2 540 000 of an inch BENEFITS Helps clear up a smokey environment quickly so customers can dine more comfortably Helps employees reduce suffering from irritated eyes nasal congestion and respiratory problems that lead to absenteeism Helps prevent damaging black and greasy particles from staining ceilings walls and furnishings reducing ...

Страница 3: ...e ionizing section is charged at approximately 7500 VDC The collecting plates are alternately grounded and charged at 5000 VDC The arrow on the cells indicates the direction of air flow which must point up towards the fan motor MOTOR AND FAN BLADE The motor is 1 33 HP 1050 RPM 3 speed controlled by a 3 position slide switch The motor is thermally protected The fan blade is 14 in 35 5 cm with a 20o...

Страница 4: ...ell well with hot water 120ºF 49ºC maximum 5 If dirt or nicotine remains on plates let cell soak in hot soapy water for 30 minutes Never use any instrument to clean the cell as this may damage the ionizing wires or misalign cell plates 6 Spray prefilter with DAX Detergent and rinse well 7 To dry cell tilt on 45º angle against wall with arrow pointing sideways Allow to dry completely for at least 8...

Страница 5: ...ker is ON or voltage is supplied to unit 2 Main supply fuse or breaker is not tripped 3 Unit cover is completely closed and locked into place 4 System switch is ON Performance Indicator Light OFF 1 System switch is ON 2 Remove cell close access door and turn unit ON If Performance Indicator is still off problem is in the power box If light comes on with no cell then there is a short circuit in the...

Страница 6: ...Electrical Schematic A 120 Volt Electrical Schematic B with Wireless Remote 120 Volt ...

Страница 7: ...Electrical Schematic A 220 240 Volt Electrical Schematic B with Wireless Remote 220 240 Volt ...

Страница 8: ...a consequence of any misapplication negligent handling improper servicing unauthorized alteration or improper operations 4 Failure to start due to voltage conditions blown fuses open circuit breakers or other damages due to the inadequacy or interruption of electrical service 5 Damage as a result of floods winds fires lightning accidents corrosive atmosphere or other conditions beyond the control ...

Отзывы: