pull the lamp, by the base, away from the lamp
socket. Remove the lamp from the support clip.
Remove the plastic lamp support clips by
pinching the back of the clip and lightly pulling
away from the reflector.
4. Before replacing the lamps, the reflector should be
cleaned with a soft cloth and mild non-abrasive
soap.
5. Replace the support clips by pressing them into
the hole in the reflector.
6.
NEVER
use any lamp other than from the original
manufacturer.
NEVER
run the Air Cleaner with
only one lamp.
7. When replacing the lamp, use gloves to prevent
oil from being deposited on the glass. Hold the
lamp by the base and slide the glass end into the
plastic support clip. Slide the lamp straight into the
lamp socket until the lamp locks into place.
8. Remove the new PCO filter from the bag and slide
into the upper track under the lamps with the fuzzy
side down towards the lamps. During shipping and
handling a small amount of white dust is created.
This can be cleaned by vacuuming.
DO NOT
vacuum the filter.
9. Remove the final filter from the bag and slide it
into the track above the PCO filter with the arrow
pointing up.
Note: The Air Cleaner will not operate with this
filter removed.
2.
Replace the lamp access panel tightening all
screws. Do not over tighten.
The PCO Filter will discolor with use. This is
normal.
PCO Filter (#DM900-0450):
This must be replaced
every 2 years.
Final Filter (#DM900-0810):
This must be replaced at
least once a year.
UVC Lamp (#DM900-0191) (2 required):
Replace
every 2 years. Includes lamp support clip. Lamp may
still light after 2 years but intensity of the germicidal
wavelength will be reduced.
UVC Lamp / PCO Maintenance Kit (#DM900-1002):
Kit contains 2 UVC lamps, 2 lamp support clips, 1
PCO filter and gloves.
Complete 2-3 Year Maintenance Kit (#DM900-
1003):
Contains 1 HEPA filter, 4 carbon prefilters, 2
UVC lamps, 1 PCO filter, 2 carbon/potassium
permanganate final filters, gloves.
4
WARNING
Eye and skin damage may result from direct exposure to
the light produced by the lamps used in this product.
Make sure the Air Cleaner is
OFF
and
UNPLUGGED
before the lamp access panel is open.
CAUTION
Do not touch the lamp glass with bare hands. Always
use the gloves provided when installing the lamps. The
oil from your hands may reduce the effectiveness of the
lamp. The lamp may be cleaned with a soft cloth
dampened with water to remove finger prints.
CAUTION
The lamps operate at a very high temperature. Allow the
lamps to cool 10 minutes before touching.
WARNING
Never use the Air Cleaner without all of the filters in
place and all cover panels and doors closed. Make sure
all the screws are in place.
CAUTION
When the unit is new or after the lamps have been
replaced there may be a temporary odor. An odor may
also occur with high concentrations of chemicals in the
home such as paint or strong cleaning solutions. Both
odors are temporary and should dissipate within a short
time.
CAUTION
Always dispose of plastic bags safely. Do not allow
children or pets to play with empty plastic bags.
CAUTION
The lamps contain a very small amount of mercury
(Hg). In case of accidental breakage, handle with
extreme care. According to the EPA website, open
windows in the affected area and leave the room for 15
minutes. Do not vacuum or use a broom to clean.
Wear a dust mask and use disposable gloves. Scoop
fragments using stiff paper or cardboard. Place
fragments in a plastic bag. Wipe area with damp paper
towels and place towels in the plastic bag. Seal bag
and dispose of waste following local guidelines. Wash
hands with mild detergent and water. See the EPA
website (www.epa.gov) for more information.
CAUTION
The lamps used in this air cleaner contain a very small
amount of mercury (Hg). The lamps should be
disposed of according to local ordnances or refer to
www.lamprecycle.org.