background image

pull  the  lamp,  by  the  base,  away  from  the  lamp 
socket.  Remove  the  lamp  from  the  support  clip. 
Remove  the  plastic  lamp  support  clips  by 
pinching  the  back  of  the  clip  and  lightly  pulling 
away from the reflector. 

4.  Before replacing the lamps, the reflector should be 

cleaned  with  a  soft  cloth  and  mild  non-abrasive 
soap.  

5.  Replace  the  support  clips  by  pressing  them  into 

the hole in the reflector. 

6. 

NEVER

 use any lamp other than from the original 

manufacturer. 

NEVER

  run  the  Air  Cleaner  with 

only one lamp. 

7.  When  replacing  the  lamp,  use  gloves  to  prevent 

oil  from  being  deposited  on  the  glass.  Hold  the 
lamp by the base and slide the glass end into the 
plastic support clip. Slide the lamp straight into the 
lamp socket until the lamp locks into place. 

8.  Remove the new PCO filter from the bag and slide 

into the upper track under the lamps with the fuzzy 
side down towards the lamps. During shipping and 
handling a small amount of white dust is created. 
This  can  be  cleaned  by  vacuuming. 

DO  NOT

 

vacuum the filter. 

9.  Remove  the  final  filter  from  the  bag  and  slide  it 

into the track above the PCO filter with the arrow 
pointing up. 

 

Note:  The  Air  Cleaner  will  not  operate  with  this 
filter removed.

 

2. 

Replace  the  lamp  access  panel  tightening  all 
screws. Do not over tighten.

 

The  PCO  Filter  will  discolor  with  use.  This  is 
normal. 

 
 

 
PCO  Filter  (#DM900-0450):

  This  must  be  replaced 

every 2 years.  

Final Filter (#DM900-0810):

 This must be replaced at 

least once a year.  

UVC  Lamp  (#DM900-0191)  (2  required):

  Replace 

every 2 years. Includes lamp support clip. Lamp may 
still  light  after  2  years  but  intensity  of  the  germicidal 
wavelength will be reduced. 

UVC Lamp / PCO Maintenance Kit (#DM900-1002): 

Kit  contains  2  UVC  lamps,  2  lamp  support  clips,  1 
PCO filter and gloves. 

Complete  2-3  Year  Maintenance  Kit  (#DM900-
1003): 

Contains  1  HEPA  filter,  4  carbon  prefilters,  2 

UVC  lamps,  1  PCO  filter,  2  carbon/potassium 
permanganate final filters, gloves. 

WARNING  

Eye and skin damage may result from direct exposure to 
the  light  produced  by  the  lamps  used  in  this  product. 
Make  sure  the  Air  Cleaner  is 

OFF

  and 

UNPLUGGED

 

before the lamp access panel is open. 

CAUTION  

Do  not  touch  the  lamp  glass  with  bare  hands.  Always 
use the gloves provided  when  installing the lamps. The 
oil from your hands may reduce the effectiveness of the 
lamp.  The  lamp  may  be  cleaned  with  a  soft  cloth 
dampened with water to remove finger prints. 

CAUTION  

The lamps operate at a very high temperature. Allow the 
lamps to cool 10 minutes before touching. 

WARNING  

Never  use  the  Air  Cleaner  without  all  of  the  filters  in 
place and all cover panels and doors closed. Make sure 
all the screws are in place. 

CAUTION 

When  the  unit  is  new  or  after  the  lamps  have  been 
replaced  there  may  be  a  temporary  odor.  An  odor  may 
also  occur  with  high  concentrations  of  chemicals  in  the 
home  such  as  paint  or  strong  cleaning  solutions.  Both 
odors are temporary and should dissipate within a short 
time.  

CAUTION  

Always  dispose  of  plastic  bags  safely.  Do  not  allow 
children or pets to play with empty plastic bags. 

CAUTION  

The  lamps  contain  a  very  small  amount  of  mercury 
(Hg).  In  case  of  accidental  breakage,  handle  with 
extreme  care.  According  to  the  EPA  website,  open 
windows in the affected area and leave the room for 15 
minutes.  Do  not  vacuum  or  use  a  broom  to  clean. 
Wear  a  dust  mask  and  use  disposable  gloves.  Scoop 
fragments  using  stiff  paper  or  cardboard.  Place 
fragments in a plastic bag. Wipe area with damp paper 
towels  and  place  towels  in  the  plastic  bag.  Seal  bag 
and dispose of waste following local guidelines. Wash 
hands  with  mild  detergent  and  water.  See  the  EPA 
website (www.epa.gov) for more information. 

CAUTION  

The lamps used in this air cleaner contain a very small 
amount  of  mercury  (Hg).  The  lamps  should  be 
disposed  of  according  to  local  ordnances  or  refer  to 
www.lamprecycle.org. 

Содержание FSP900-2

Страница 1: ...les to extend life of HEPA Filter Two High Output Ultraviolet Germicidal Lamps CinQuartz Photo Catalytic Oxidation Filter removes unpleasant odors and Volatile Organic Compounds Carbon Potassium Permanganate Final Filter removes non organic gases Kills or inhibits bacteria viruses mold fungi and microbial growth Easy to change filters and lamps Mobile Easily moves from room to room Powerful Variab...

Страница 2: ...et Light is also used to activate the unique CinQuartz Media located above the UVC lamps The CinQuartz Photo Catalytic Oxidation PCO Filter is a Quartz media coated with nanoparticles of Titanium Dioxide TiO2 The combined action of the UVC light and the TiO2 decomposes organic materials into basic molecules such as H2O and CO2 and reduces odors and VOC s as a result Air then passes through a Final...

Страница 3: ...ants in the air and the frequency in which the Prefilter has been changed Renovations in the home that create wood drywall dust or similar contaminants will shorten the life expectancy of the HEPA filter Note Handle the HEPA filter by the frame only The paper is fragile and a puncture or tear will reduce efficiency Replacing the UVC Lamps PCO Filter and Final Filter 1 To change the PCO filter Fina...

Страница 4: ...ilter 4 carbon prefilters 2 UVC lamps 1 PCO filter 2 carbon potassium permanganate final filters gloves 4 WARNING Eye and skin damage may result from direct exposure to the light produced by the lamps used in this product Make sure the Air Cleaner is OFF and UNPLUGGED before the lamp access panel is open CAUTION Do not touch the lamp glass with bare hands Always use the gloves provided when instal...

Страница 5: ...ening or removing switch cover may expose you to dangerous voltage or other hazards Refer all servicing to qualified personnel 6 Never push objects of any kind into the Air Cleaner through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock 7 If the Air Cleaner has been dropped or the cabinet has been damaged unplug the unit fro...

Страница 6: ...ling of either defective parts or replacement parts LIMITATIONS OF WARRANTY All implied warranties including implied warranties of merchantability are hereby limited in duration to the period for which the limited warranty is given The expressed warranties made in this warranty are exclusive and may not be altered enlarged or changed by any distributor dealer or other person whatsoever FIVE SEASON...

Отзывы: