User Manual for FiT208-S Digital Alcohol Analyzer
Page 2
218-06Y01365
-use
r manual(FIT_208-S)R41-‰-2006-09-02
Enhanced feature instructions
z
Unit conversion and memory recall:
i. Hold MODE Key for 0.5 seconds to toggle Real Time clock (
RTC
) / Alcohol mode (
DAC
).
ii. Press”
▼
” UNIT key once to convert the alcohol unit in
DAC
mode, between ‰BAC; %BAC, mg/l
iii. Press ”
▲
” REV key once to scroll forward the 5 memory readings and then the average reading
iv. Hold ”
▲
” REV key for 2 seconds to clear the memory readings in alcohol mode.
z
Real time Clock setting:
i. When in Real time Clock mode, hold ”
▼
” SET key for 2 second to enter into time setting in
RTC
mode.
i. Press ”
▲
” ADV key once to advance the selected digit in
RTC
setting mode
ii. Press ”
▼
” SET key once to decrease the selected digit in real time setting mode.
iii. Press ST key once to shift the select digit in real time setting mode.
Note:
1) To ensure high precision readings, user should perform the auto-cleaning if unused for a long period. (especially for the
first time of using). User can start the auto-cleaning process by holding MODE & ”
▲
” keys together for 2 seconds or by
removing the batteries and power up again. Put a few drops of alcohol solvent (<2%) inside the provided cleaning cap
accessory. Place the cap onto the gas outlet when you see the animation of “CAP
u
”
Æ
“CAP
n
” for 10 seconds. Then
take off the cap when “Auto” & “Clr” flashes and leave the FiT208-S perform the 3 minutes auto cleaning. The analyzer will
then return to normal Alcohol mode automatically when the cleaning process finishes. Make sure no alcohol residues left
by blowing fresh air into the gas inlet before formal testing.
2) Please notice that pressing the MODE key at any time can easily terminate the auto-cleaning process.
3) To achieve an accurate reading, user should ensure there is no alcohol residue inside the chamber before starting a new
alcohol test. Users can pre-check the tester until the ‘Lo’ indication is shown on the display. This may be achieved by
pressing ST key once. Holding the ST key and blow fresh air into gas inlet for about few seconds. Alternatively, shaking
the unit forwards and backwards several times will allow any alcohol residue to leave before starting a new alcohol test.
4) After any 5 consecutive tests, allow the device to rest for 2 minutes.
5) An “Err” flashes on the display for 5 seconds for the following improper operations:-
i.
When user does not hold the BLOW key for at least 6 seconds during blowing until a beep sound is heard.
ii. When user fails to start the test within 10 seconds after “READY” turns on and “blow” flashes.
User can press MODE Key once to stop the alarm sound of Err.
Storage and handling:
6) When the product is left unused, please store in a dry environment.
7) When low battery inductor flashes, the reading is not valid, please replace the batteries immediately.
8) This is an instrument for breath alcohol concentration, user should avoid the tester from high impacted or drop. Please
ask for the recalibration from your nearby service centre if such kind of abnormal impact occurred.
9) Recalibration: According to the international standard (e.g. DIN31051), all measurement instrument should be
recalibrated every 6 months.
Product Specifications:
1.
Range:
0.15 ~ 1.5
‰
BAC
2.
Power Input:
3pcs AAA 1.5V
Alkaline
batteries
3.
Display:
Graphic & Digital display with tri-color backlighting
4.
Real time clock power save mode:
2 minutes after any key in
5.
Breath sampling:
About 6 seconds continuous breath sample
6. Recycle
time:
~20
seconds
7.
Dimensions:
88 X 47 X 24 mm approx.
8.
Weight:
50 (without batteries)
9.
Alert level calibrated:
□0.2‰ □0.3‰ □0.5‰
□0.8‰
BAC
10. Agency
Approval:
CE
11.
Accessories:
3 pcs blowing tubes; 1 pc Auto-cleaning cap
The FIT 218 Digital Alcohol Analyzer should be used as a general guide to the level of alcohol in your body.
Many factors (e.g. environment gas residue, smoke & various smell in human mouth, etc…)
may affect the BAC level, so the Readings are For Reference Only.
Neither the reseller nor manufacturer accept any liability arising from the use of this unit
D
D
O
O
N
N
O
O
T
T
d
d
r
r
i
i
n
n
k
k
b
b
e
e
f
f
o
o
r
r
e
e
y
y
o
o
u
u
d
d
r
r
i
i
v
v
e
e
!
!
Specification subject to change without notice
Made in China.