8. PARAMETER: 

 

 

Select mode  

Pressing the PROG key switches to the next program and to manual mode 
 
Manual: 

In  this  mode,  the  dispense  time  does  not  get  saved  and  the  rotary  valve 
dispenses as long as the dispense signal is activated by one of the following: 
footswitch / purge key / I/O-start.  
After dispensing, the dispense time starts again at 0.00 sec. 

 
PROG 1-7:   If one of the programs 1 

 7 is selected, the RVC900N dispenses as long as 

the value of the dispense time is set for. This dispense cycle  is activated  by 
one of the following: footswitch / purge key / I/O-start.  
This mode should be selected, if the rotary valve should always dispense for 
the same time.  

 

 

Set the dispense time: 

The dispense time can be selected with the UP / DOWN keys, and set from 0.01 - 999.99 
sec. 
 

 

Set the rotation speed:  

The rotation speed of the rotary valve can be selected in linear steps.  
The value from 001 - 100 is related to the rotary valve voltage 0 - 24V.  
 

 

Set the wait time:  

The wait time is the pause time between end of dispensing and starting the retract of the 
rotary valve. This value is limited to max. 5 sec.  
 

 

Set the retract: 

The  retract  is  the  time,  which  the  rotary  valve  moves  in  the  inverted  direction  to  the 
dispense  direction.  With  this  function,  dropping  of  material  out  of  the  dispense  tip,  after 
finishing the dispense procedure can be prohibited. This value is limited to max. 5 sec.  

 

 

Cycle counter: 

The  cycle  counter  counts  the  dispensing  procedures  after  switching  ON  the  RVC900N 
controller.  The  memory  of  the  cycle  counter  is  volatile  and  gets  reset  to  000000  after 
switching OFF the unit. 

 

 

Rotation Direction:

 

The  rotation  direction  of  the  rotary  valve  can  be  set  for  clockwise  and  counter  clockwise. 
The selected direction is shown in the display as follows:  
 
CW: 

Clockwise - spindle moves clockwise 

CCW: 

Counter clockwise - spindle moves counter clockwise 

 
The rotation direction can be selected in the SERVICE MENU 

Содержание RVC900N Series

Страница 1: ...RVC900N Rotary Valve Controller Rev A Nov 10 RVC900N Series ROTARY VALVE CONTROLLER U Us se er r M Ma an nu ua al l...

Страница 2: ...RVC900N Rotary Valve Controller Rev A Nov 10 This page intentionally left blank...

Страница 3: ...1 Parts description 4 5 Included parts 5 6 Start operation 5 7 Operation 6 7 1 Display 6 7 2 Status LED s 6 7 3 Operation keys 7 8 Parameter 8 9 Service Menu 9 9 1 Display 9 9 2 Settings 9 10 Electri...

Страница 4: ...00N controller only for the functions which are explained in this user manual Fisnar Inc is not responsible for personal or material damages which happen because of incorrect usage DO NOT modify the R...

Страница 5: ...lbs 1 65kg Power Supply 100 240V AC 50 60Hz Internal Voltage 24V DC Voltage Rotary Valve 0 24V DC PWM Dispense Time 0 01 999 sec Air Inlet 0 100psi 0 7bar Display digital Air Outlet 0 58 psi 0 4bar pr...

Страница 6: ...Front Side Back Side Pressure gauge for air outlets Air pressure regulator Operating keys Status LED s Graphic display Rotary valve 0 24V DC PWM Footswitch Power switch Air outlet continuous Air outl...

Страница 7: ...nding on your application use the continuous or pulsed air outlet for the air supply of the material reservoir Adjust the air outlet pressure with the pressure regulator on the front side of the RVC90...

Страница 8: ...ndependent to the rotation direction ALARM The ALARM LED lights during the following conditions Pressure alarm is active Motor current overload only active for speed 50 External alarm signal on the I...

Страница 9: ...2 sec and select the wanted program with the UP DOWN keys and press SAVE again to store the parameters If no different program is selected the parameters get automatically saved in the actual program...

Страница 10: ...e can be selected in linear steps The value from 001 100 is related to the rotary valve voltage 0 24V Set the wait time The wait time is the pause time between end of dispensing and starting the retra...

Страница 11: ...CW Counter clockwise spindle moves counter clockwise P Unit Pressing UP DOWN keys switches between PSI and BAR as unit for the digital displayed pressure P Alarm By pressing the UP DOWN keys the value...

Страница 12: ...nsing 10 3 I O Port type 15 pol SubD female 2 doublerow pins see following chart pin no Input Output Description Comment 1 Reserved Reserved 2 GND GND 3 24V DC 24V DC 4 Output BUSY Dispensing procedur...

Страница 13: ...0 11 10 4 Wiring Diagrams Digital Inputs A digital input is active if the opto coupler is ON If the opto coupler is connected to GND the input is activated Digital Outputs If the digital output is act...

Страница 14: ...be done by the manufacturer Clean the RVC900N controller only with a clean smooth and dry cloth Do not use dissolvent material to clean the RVC900N controller The foil at the front back plate or the...

Отзывы: