FISNAR EP1320C Скачать руководство пользователя страница 3

EP1320C OPERATION MANUAL

 

Rev. A - November, 2013 

 

 

3 | 

P a g e

 

SECTION 1 

 

GENERAL SAFETY WARNINGS 

 
 

1.  Equipment Misuse Hazards 

 

 

 
 

Any  misuse  of  the  dispensing  equipment  or  accessories  such  as  over-
pressurizing,  modifying  parts,  using  incompatible  chemicals  and  fluids,  or  using 
worn or damaged parts, can cause item to rupture and result in fluid splashing in 
the eyes or on to the skin. 

 

Never  alter  or  modify  any  part  of  this  equipment,  doing  so  could  cause  it  to 
malfunction. 

 

Check  all  dispensing  equipment  regularly  and  repair,  or  replace  worn  or 
damaged parts immediately. 

 

Always  wear  protective  eyewear,  gloves  and  clothing,  as  recommended  by  the 
material and solvent manufacturers. 

 

Never exceed the maximum air inlet pressure of 7 bar (100 psi). 

 

Do  not  exceed  the  maximum  working  pressure  of  any  component  or  accessory 
used in the system. 

 

Be  sure  that  all materials  and  solvents  used  are  chemically  compatible  with  the 
wetted  parts.  Always  read  the  manufacturer's  literature  before  using  material  or 
solvent in this pump. 

 

 

 
 
 

Содержание EP1320C

Страница 1: ...EP1320C OPERATION MANUAL Rev A November 2013 1 P a g e CARTRIDGE PUMP MODEL EP1320C OPERATION MANUAL...

Страница 2: ...g e CONTENTS 1 Safety 3 2 Introduction 7 3 Specification 8 4 Control Panel 9 5 Installation Set up Operation 11 6 Troubleshooting 14 7 Exploded View Parts List 15 8 Dimensions 20 9 Technical Data 21 R...

Страница 3: ...t of this equipment doing so could cause it to malfunction Check all dispensing equipment regularly and repair or replace worn or damaged parts immediately Always wear protective eyewear gloves and cl...

Страница 4: ...pressure fluid can dislodge a loose coupling or allow high pressure spray to be emitted from the coupling Never use a damaged hose Before each use check the entire hose for cuts leaks abrasion or dama...

Страница 5: ...ng and or servicing the machine The air motor the fluid area of pump and the motor will move whenever the machine is activated Keep hands and fingers away from the air motor during the priming and ins...

Страница 6: ...r whether the power cord is plugged or not This spark may ignite any solvent dust particles and other combustible materials in or near the machine and may cause fire explosion or serious injuries If y...

Страница 7: ...ow management A low pulse design allows automatic control of dispensing application The EP1320C tandem cartridge pump is designed to easily transfer material for controlled dispensing via a high press...

Страница 8: ...A November 2013 8 P a g e SECTION 3 SPECIFICATION Power Requirements 220VAC 10 50 60Hz Power Consumption 10W Max Air Inlet 9 9kgf cm2 Pump Ratio 15 1 Weight 18 5kg Temperature Range 5o C 40o C Dimens...

Страница 9: ...EP1320C OPERATION MANUAL Rev A November 2013 9 P a g e SECTION 4 Control Panel...

Страница 10: ...which cartridge is being used Pressing Replace indicates cartridge us being replaced 4 Lamp On Off Cartridge is empty when light is ON 5 Indicates which side cartridge is being used and or replaced P...

Страница 11: ...utlet of the pump Please refer to the valve manual for additional information 2 Connect air inlet of dispensing valve and air outlet of controller with connect tube Please refer to the valve and contr...

Страница 12: ...P a g e 2 Set Up No Installing Replacing the Cartridge 1 Turn the cartridge holder counter clockwise and pull to remove 2 Insert the cartridge with the outlet facing down 3 Replace the cartridge holde...

Страница 13: ...to the required dispense pressure 2 Open the bleed port C to extract bubbles and close slowly 3 Set air pressure over 30psi with air regulator B Open the air valve slowly until material starts flowing...

Страница 14: ...not work Pump stroke is short Flow rate is slower than usual Pump actuates quickly Pump does not go up down Probable Cause Recommended Maintenance Insufficient air pressure Defective air valve Defect...

Страница 15: ...EP1320C OPERATION MANUAL Rev A November 2013 15 P a g e SECTION 7 EXPLODED VIEW AND PARTS LIST 1 Main Body...

Страница 16: ...BS 2 25 BLEED COCK BS 1 27A B C REGULATOR SET TACO 3 28 ELBOW BS 1 56 FOOT BS 4 70 BASE PLATE AL6061 1 101 CAP STS 1 102 CYLINDER AL6061 1 103A B C O RING NBR 3 104A B PISTON AL6061 1 106 ROD SM45C 1...

Страница 17: ...EP1320C OPERATION MANUAL Rev A November 2013 17 P a g e 2 Pump Head...

Страница 18: ...CYLINDER 1 60 102 1 PUMP HEAD CYLINDER 2 80 84 FITTING KQ2L08 02S 104 1 PUMP HEAD UPPER PISTON 60 104 1 1 PUMP HEAD UPPER PISTON 80 104 2 PUMP HEAD PISTON 60 104 2 1 PUMP HEAD PISTON 80 104 3 PUMP HEA...

Страница 19: ...NG BASE 1 196 1 PUMP FLUID HOUSING BASE 2 196 2 PUMP FLUID HOUSING BASE 3 196 3 PUMP FLUID HOUSING BASE 4 163 PUMP FLUID V PACKING 1 163 1 PUMP FLUID V PACKING 2 163 2 PUMP FLUID V PACKING 3 109 PUMP...

Страница 20: ...EP1320C OPERATION MANUAL Rev A November 2013 20 P a g e SECTION 8 DIMENSIONS...

Страница 21: ...range input 1 8 7 0Kg Cm Maximum fluid viscosity 600 000 cps Dispensing volume per a stroke 5 0cc Maximum fluid speed 250 000 cps fluid 940 cc min Maximum stroke 19 mm Maximum temperature for operati...