Important Safety Instructions

To ensure your personal safety and the safety of others, operate this apparatus only after reading these instructions 

and heeding the warnings listed below. 

1. 

Read these instructions.

2. 

Keep these instructions.

3. 

Heed all warnings.

4. 

Follow all instructions.

5. 

Do not use this apparatus near water.

6. 

Clean only with a dry cloth.

7. 

Do not block the ventilation openings. Install in accordance with the manufacturer's instructions.

8. 

Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including 
amplifiers) that produce heat.

9. 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The 
wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, 
consult an electrician for replacement of the obsolete outlet.

10. 

Protect the power cord from being walked on or pinched, particularly at the plugs, convenience receptacles 
and the point where they exit from the apparatus.

11. 

Use only attachments/accessories specified by the manufacturer.

12. 

Use only with a cart, stand, tripod, bracket or table specified by the manufacturer, or sold with the 
apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury 
from tip-over.

13. 

Unplug this apparatus during lightning storms or when unused for long periods of time.

14. 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been 
damaged in any way, such as a power-supply cord or plug is damaged, liquid has been spilled or objects 
have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate 
normally, or has been dropped.

15. 

Do not expose the apparatus to dripping or splashing liquids and do not place objects filled with liquids 
(such as a beverage container or a vase) on the apparatus.

16. 

Warning” To reduce the risk of fire or electric shock, do not expose this apparatus to moisture.

17. 

The apparatus should be connected to mains outlet with a protective earthing connection.

 

Disconnect device is Mains Plug, which should remain readily operable.

Copyright © 2010 FISHMAN TRANSDUCERS, INC.

All rights reserved. No part of this document may be reproduced in any form without the 
written permission of FISHMAN TRANSDUCERS, INC.

No user serviceable parts inside.

Refer servicing to qualified personnal.

Do not expose to rain or moisture.

CAUTION

Risk of electric shock.

Do not open.

Wherever this symbol appears, it alerts you to the 
presence of uninsulated dangerous voltage inside 
the enclosure that may be sufficient to constitute a 
risk of shock.

Whenever this symbol appears, it alerts you to the 
presence of important operating and maintenance 
(servicing) instructions in the user’s manual for this 
amplifier.

Содержание Loudbox Mini

Страница 1: ...USER GUIDE LOUDBOX MINI...

Страница 2: ...cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel...

Страница 3: ...els SPLs without protection can cause permanent hearing loss OSHA has set guidelines and specified permissible sound exposure limits for those who work in high SPL environments Permissible Noise Expos...

Страница 4: ...nk you for making Fishman a part of your acoustic experience We are proud to offer the nest acoustic ampli cation products available high quality professional grade tools which empower you to sound yo...

Страница 5: ...t the other 1 Locate the Power switch next to the rear panel power cord terminal and switch it off then connect the power cord 2 Plug the Loudbox Mini into an electrical outlet with the appropriate AC...

Страница 6: ...s With the dial set at 12 o clock the control is effectively out of the circuit 5 Mid This control affects how well the instrument blends in or stands out in the mix At loud volumes a midrange cut wil...

Страница 7: ...higher levels With the dial set at 12 o clock the control is effectively out of the circuit 12 High Boost highs to add air to the sound of the microphone With the knob set at 12 o clock the control i...

Страница 8: ...your region at the other Disconnect device is AC inlet or power switch 2 Power switch Lower the Master Volume before you turn on the amp Flip the power switch to the up position 3 4 Aux Input 1 4 1 8...

Страница 9: ...human ear is quite sensitive to midrange Cut the Mid control to about ten o clock or to your taste At this level our perception of bass and treble starts to catch up to the rest of the tonal spectrum...

Страница 10: ...us In Reverb In Mic Reverb Level Instrument Reverb Level 1 4 Stereo Aux Inputs Tip Left Ring Right 1 8 Mic Input Mic Preamp Gain Low High Hi Pass Filter Phase Class A Buffer Limiter 60Watt Power Amp G...

Страница 11: ...Hz resonant Mid 10 5dB 750Hz resonant High 12 5dB 15kHz shelving Mix D I out Output Impedance 600Ohm balanced mic level Phantom power tolerant ground isolated Speaker system Woofer 6 5 paper cone Twee...

Страница 12: ...www shman com Fishman and Fishman Transducers are trademarks or tradenames of Fishman Transducers Inc 513 300 170 Rev C 8 10...

Отзывы: