Fishguard Fx Floodlight Скачать руководство пользователя страница 1

User Manual

Содержание Fx Floodlight

Страница 1: ...User Manual ...

Страница 2: ...eplacement 7 Ambient Lighting 8 Front Elevation 9 Rear Elevation 10 Battery Replacement 11 Activating Security 12 System Communication Optimum Range 13 System Setup Fx Sensor Alignment 14 Fx Sensor Field of View 15 Swim Setups 18 26 Troubleshooting 27 28 Product Care Cautions 30 Batteries 30 Guarantee 29 Contents Optimum Height 16 Fx Sensor Detection 17 ...

Страница 3: ...Fx Control Unit Fx Sensor Fx Sensor 1 Fishguard Fx System Fx Floodlight Add on Fx Sensor Add on ...

Страница 4: ...Fx Floodlight White LED Fx Sensor Red LED Speaker Antenna Sound Selection Pairing Fx Control Unit Blue LED Pairing Point Fx Sensor Green LED Fx Sensor Amber LED 2 Front Elevation Fx Control Unit ...

Страница 5: ... Mode Door Bell Dog Growl Dog Bark Owl Hoot System Status Check LEDs for all active units will illuminate when selecting an alternative sound LEDs will go out after 5 seconds 3 Sound Selection Fx Control Unit ...

Страница 6: ... Release Turn Quarter Turn Lock anticlockwise to unlock clockwise to lock with unit facing up 4 x AA Batteries required Up to 70 hours battery life at the same time 4 Battery Replacement Fx Control Unit The EndCap fits tightly pinch bothends and remove both sides ...

Страница 7: ...Security Lighting Locking Disc Ambient Detection Lens Fx Floodlight Front Elevation 5 Ambient Lighting Battery Twist Lock ...

Страница 8: ...Security Dimmer Battery Twist Lock Security Status LED Ambient Dimmer Ambient Lighting Locking Disc Ambient Detection Lens Rear Elevation 6 Fx Floodlight Security Liight On Off Ambient Light On Off ...

Страница 9: ...Battery Twist Lock Battery Tray Battery Replacement Fx Floodlight 7 Turn battery twist lock anticlockwise to release clockwise to lock 4 x AA Batteries required Up to 80 hours battery life ...

Страница 10: ...Lighting will illuminate Ambient Lighting is activated by infrared sensors behind the Ambient Detection Lens Ambient Lighting will go out 30 seconds after last detection Detection Range up to 3m 8 Turn Ambient Lighting Off Ambient Lighting will go out ...

Страница 11: ...Detection Lens Locking Disk Battery Twist Lock Fx Sensor Front Elevation 9 Take care not to mark Detection Lens ...

Страница 12: ...Locking Disk Battery Twist Lock Sensor Status LED Rear Elevation 10 Silicon Band optional Use Silicon Band to cover Sensor Status LED if visible at night Fx Sensor ...

Страница 13: ...Battery Twist Lock Battery Tray Battery Replacement Fx Sensor 11 Turn battery twist lock anticlockwise to release clockwise to lock 2 x AA Batteries required Up to 500 hours battery life ...

Страница 14: ... Off button The corresponding Control Unit LED will illuminate Security Lighting will illuminate for 2 seconds When all active units are operational the LEDs on the Control Unit will illuminate for 5 seconds then go out When a Fx Sensor detects motion it will trigger the Control Unit selected sound and Security Lighting The corresponding LED on the Control Unit will rapid flash Low Batteries are i...

Страница 15: ...Optimum range is achieved by keeping the Control Unit upright at all times 100m range 13 Optimum Range System Communication System range will be severely effected if the Control Unit is laid flat ...

Страница 16: ...Vertically align Fx Sensor for optimum detection and reliability 0 0 Fx Sensor Alignment 10 20 10 20 10 20 10 20 System Setup 14 ...

Страница 17: ...Field of view 15 Keep Fx Sensor Unit faces clear of branches and foliage to avoid false detection Be aware of environmental movement in windy conditions System Setup ...

Страница 18: ...System Setup Optimum Height Fx Sensors can be set at any height For optimum performance of the ambient lighting the Fx Floodlight should be set minimum of 500mm 16 100mm 200mm 400mm 500mm 600mm 700mm ...

Страница 19: ...erent colour status LED indicating which Sensor is triggered Position the Fx Sensors like trip wires Detectionis most effective when crossing the invisible beam Detection range can be affected by extreme light and temperature ideally suited to nightime operation ...

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ...red to the system Pairing procedure Select pairing mode on the Control Unit On the unpaired Unit ensure it is On then push and hold the button The Status LED will start to flash then face it against the Pairing Point on the Control Unit The corresponding LED will illuminate on Control Unit and the unit is paired System not responding The Control Unit is in pairing mode Select a sound on the Contro...

Страница 27: ...ries with new premium batteries Corresponding Fx Sensor or Fx Floodlight LEDs showing ON continuously on Control Unit The corresponding Unit batteries are exhausted Out of range Fx Sensor or Fx Floodlight has been turned off Replace batteries with new premium batteries Ensure Fx Sensors and Fx Floodlight are within 100m of the Control Unit Ensure Control Unit is upright Turn Fx Sensor Fx Floodligh...

Страница 28: ...y Lighting LEDs Take care not to mark the Detection Lenses Avoid using excessive force on any of the knobs Clean product with damp cloth only don t use chemicals or cleaning products Avoid using abrasive materials on the product Avoid spraying product with anything lubricants chemicals etc Control Unit antenna is not removable Mogoza Ltd will not be held responsible for the use of our product in c...

Страница 29: ...ds and use batteries before their Use By date Battery life will be affected by product use and batttery quality Guarantee Mogoza Ltd will repair or replace at our discretion any faulty units within 2 years from date of purchase provided proof of purchase is retained Mogoza Ltd may refuse to repair or replace where tampering has occured or units have been abused in contravention of product care gui...

Страница 30: ... 2020 Mogoza Ltd All rights reserved ...