![Fisher FP-120AE-R Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/fisher/fp-120ae-r/fp-120ae-r_service-manual_2294421027.webp)
25
3. Unit idle for a long time
※
Remove the rubber plug at the back of the unit and attach a hose to drain outlet. Place the open end
of the hose directly over the drain area in your basement floor (See below Fig.23).
※
Remove the plug from the bottom drain outlet, all the water in the bottom tray would drain out
(See below Fig.23)
※
Keep the appliance running on FAN mode for half a day in a warm room to dry the appliance inside
and prevent mold forming.
※
Stop the appliance and unplug it, wrapped the cord and bundle it with the tape. Remove the batteries
from the remote controller.
※
Clean the air filter and reinstall it.
※
Disconnect the exhaust hose, keep it safety, and cover the window(wall) hole with the adaptor cap