Instruction Manual
D104138X012
D2T FloPro Valve
June 2017
2
Table 1. Specifications
Valve Assembly Pressure Class
ASME B16.34 CL900
Maximum Inlet Pressure and Temperature
(1)
155 bar from -46 to 93
°
C, and 150 bar at 149
°
C.
(2250 psig from –50 to 200
°
F, and 2185 psig at
300
°
F)
Maximum Allowable Pressure Drop
(1)
Flow Down
(2)
Maximum Inlet Pressure:
155 bar (2250 psig)
Maximum Outlet Pressure:
103 bar (1500 psig)
Flow Up
Maximum Inlet Pressure:
103 bar (1500 psig)
Maximum Outlet Pressure:
103 bar (1500 psig)
Shutoff Classification
Class IV ANSI/FCI 70‐2 and IEC 60534‐4
Construction Materials
Valve Body and Bonnet:
ASME SA 352 LCC
Valve Plug and Seat:
J
R30006 (Alloy 6) or
J
S17400 double H1150
Valve Stem:
S31600
O‐Rings:
HNBR (Hydrogenated Nitrile)
Packing:
PTFE/Carbon PTFE
Packing Springs:
N07718
Stem Bushing:
PPS (polyphenylene sulfide)
Actuator Diaphragm:
Nitrile/Polyester
Actuator Springs:
Zinc‐plated steel
Flow Characteristic
FloPro Characterized
Port Diameter
13 mm (0.5 inch)
Maximum Travel
13 mm (0.5 inch)
Approximate Weight
7.7 kg (17 lb)
Material Temperature Capabilities
Valve Body Assembly:
-46 to 149
°
C (-50 to 300
°
F)
Actuator Assembly:
-46 to 93
°
C (-50 to 200
°
F)
Bonnet/Body Connection
Threaded with leakoff bleed
Standard Actuator Configuration
The D2T FloPro
actuator is an on/off
spring‐and‐diaphragm.
Globe Valve Body:
Supplied as either Air‐to‐Open or
Air‐to‐Close.
Maximum Actuator Casing Pressure
2.8 bar (40 psig)
Minimum Required Actuator Casing Pressure
2.1 to 2.4 bar (30 to 35 psig)
Actuator Diaphragm Effective Area
194 cm
2
(30 square inches)
Actuator Pressure Connections
1/4 NPT internal
1. The pressure or temperature limits in the referenced tables and any applicable ASME code limitations should not be exceeded.
2. Standard flow direction.
Educational Services
For information on available courses for Fisher D2T valves, as well as a variety of other products, contact:
Emerson Automation Solutions
Educational Services - Registration
Phone: 1-641-754-3771 or 1-800-338-8158
E-mail: [email protected]