background image

PINPOINTING/DEPTH READING

Pushbutton Pinpoint Mode

Target location is quick and easy using the SEARCH/
PINPOINT touch pad. And when you pinpoint your

target, your CZ-7a Pro will give you an approximate

(usually within an inch or so) depth reading for
coin-sized targets. It doesn't matter which mode

you're in (ID. or Autotune), and you don't have to keep the
search coil in motion to get a response as long as the SEARCH/
PINPOINT pad is pressed.

1.

Once the presence of a target is indicated by

the "beep-beep" of your CZ-7a Pro, simply move
the coil at least 1 foot away from the target area
(and any other metal), and set it lightly on the
ground.

2.

Press and hold the SEARCH/PINPOINT pad.

After a brief pause, a scale from 0 to 10, a
MARKER and the word "INCHES" will appear on
the LCD.

3.

Still pressing the SEARCH/PINPOINT touch pad,

bring the search coil back over the target area.
Note that as you approach the target, the
volume and pitch increase. Also, the marker will
indicate signal strength and approximate depth.
The farther to the right the marker goes, the
weaker the signal and the deeper the target.

4.

Slowly move the coil from left to right, forward

and backward over the target, until you can
determine exactly where you get the strongest
response as indicated by volume., pitch and LCD
marker.

5.

With your thumb still on the SEARCH/PINPOINT

pad, stop the coil and rest it lightly on the ground.

6.

Note the position of the LCD marker. If, for

example, the marker is over the 4 (and your
target is coin-sized), your target should be about
4 inches below the center of your search coil.

7.

If you're more interested in finding your target

31

Содержание CZ-7a PRO Quicksilver

Страница 1: ...CZ 7a PRO Quicksilver Operating Manual Deep Search Body Mount Target I D Metal Detector F I S H E R R E S E A R C H L A B O R A T O R Y...

Страница 2: ...und Balancing pg 17 Pushbutton pg 18 Bobbing pg 19 Search Modes pg 22 Autotune pg 22 Target I D pg 23 Audio Response Chart pg 25 Searching pg 28 Pinpointing Depth Reading pg 31 Target Identification p...

Страница 3: ...d a command 3 Liquid Crystal Display with Back Light A large liquid crystal display gives you quick and accurate information about the target operating mode and battery condition Use this function spa...

Страница 4: ...tegories 8 Silent Search Slow Motion Target LD Mode No threshold tone no chatter The audio and visual target ID circuits ignore everything you ve notched out For example if you ve notched out iron tar...

Страница 5: ...dentify 15 Wet Sand Operation Just press the NORM SALT touch pad reset the ground control and you can search wet salt sand like nobody s business In fact you can submerge the coil for shallow saltwate...

Страница 6: ...n The CZ 7a Pro breaks down to fit into an optional carrying case not much bigger than a briefcase and small enough for most airline carry on luggage 23 Last Setting Turn On Memory When you turn your...

Страница 7: ...3 Adjust the stem length and coil angle so that the search coil rests flat on the ground about 6 to 12 inches in front of and slightly to the right of your right foot to the left of your left foot for...

Страница 8: ...ly adjusted wrap the search coil cable snugly around the lower stem and the center section Leave just enough slack near the coil to allow it to be tilted completely backward and forward NOTE A loose c...

Страница 9: ...e shaft length and coil angle properly adjusted you should be able to move into your search position by leaning forward very slightly and raising angle so the coil rests flat on the ground about 6 to...

Страница 10: ...ver the brass posts on the bottom of the control housing and pulling it toward the control panel to lock it in place 4 Reconnect the cable to the control housing 5 The control housing can then be moun...

Страница 11: ...e the GROUND BALANCE knob clockwise to the red 5 3 Press and release the PRESET touch pad 4 Your CZ 7a Pro is now in a coins only mode preset at the factory to accept U S coins and reject small ferrou...

Страница 12: ...target 8 When you get a good repeatable signal pinpoint the target by placing the coil on the ground away from the target pressing and holding the SEARCH PINPOINT pad and then bringing the coil back o...

Страница 13: ...Use this function sparingly as it will significantly reduce battery life VOL Press and hold until the numbers 0 10 a row of cursors and the abbreviated word VOL appear Adjust the volume by using the...

Страница 14: ...ou know which mode you are in See p 17 for more on the Autotune mode SENS Press and hold until the numbers 0 10 a row of cursors and SENS appear Adjust sensitivity as you did the volume above Exit the...

Страница 15: ...o indication on the LCD to alert you to the fact that you may have changed your volume modes sensitivity and notch settings NOTCH Press and hold the NOTCH pad until you see a cursor appear below the r...

Страница 16: ...se this pad to get out of the Volume Sensitivity and Notch functions You must do this if you are in one of these functions VOL for example and you want to get into another function NOTCH for example P...

Страница 17: ...to press the SEARCH PINPOINT pad and moving the search coil back over the target The approximate depth in inches is indicated by the position of the markers over the numbers When pressed and held the...

Страница 18: ...over a large shallow target NOTE If your headset has volume controls first adjust your headset volume controls to minimum and the CZ 7a Pro volume to maximum Then gradually increase the headset contro...

Страница 19: ...ve only a minimal response to ground mineralization Precise adjustment of the GROUND BALANCE control is critical for optimum performance The higher the degree of ground mineralization or the higher th...

Страница 20: ...in either the Autotune or Target LD mode 1 With your controls set as in the Turn On procedure See page 9 GROUND BALANCE control at 10 hold your search coil parallel to the ground and 6 to 12 inches o...

Страница 21: ...eralization Just leave the GROUND control at 10 and begin searching Bobbing the Search Coil Ground Balance Method 1 Set the detector as in the Turn On procedure on p 9 making sure the AUTO I D control...

Страница 22: ...gain As you bob the search coil one of three things will happen to your threshold hum 1 It will fade again as you lower the coil and increase as you raise it 2 It will get louder as you lower the coil...

Страница 23: ...control at 10 you re probably over a piece of metal Move away and try again 2 If you get a sudden bell tone not preceded by an increasing audio response you re probably in some very highly mineralized...

Страница 24: ...de To realize the benefits of the Autotune mode search in the Autotune mode until you find a target Pinpoint the target using the SEARCH PINPOINT pad and then push the AUTO I D touch to switch to I D...

Страница 25: ...foil on the ground at least 18 inches apart Include some large targets as well jar lids soda cans etc 2 Using the NOTCH and Arrow pads set the NOTCH control to accept all target categories Set the sen...

Страница 26: ...metal detectors have a difficult time separating gold rings nickels tabs and foil But the patented circuitry of your CZ 7a Pro can easily tell the difference between nickels and most trash Better yet...

Страница 27: ...ategory by removing the marker from below the IRON icon You will find that the CZ 7a Pro rejects small iron targets and no longer responds either with an audio tone or a display identification LCD in...

Страница 28: ...ow pads You can reject notch out any combination of target categories For example if you re hunting for iron Civil War relics you can reject every category except IRON Or if you re hunting in an area...

Страница 29: ...loaded with round tabs however you could notch them out also You d lose rings that fail into that category but you d still get all the rings falling into the rectangular tab foil and nickel categorie...

Страница 30: ...re so the audio response will give them some clue as to the target s depth or size 4 Only experience will tell you how to set your sensitivity in every situation but you ll probably want to run it as...

Страница 31: ...that your coil s search pattern in conical and if you don t overlap each sweep you ll miss the deeper targets 8 Search in a methodical manner Pay close attention to where you re going and where Keep...

Страница 32: ...Autotune search mode 4 Missed target Many targets well within the range of you CZ 7a Pro will not be detected unless you overlap your sweeps Effects of sweep speed ground mineralization and search mod...

Страница 33: ...0 to 10 a MARKER and the word INCHES will appear on the LCD 3 Still pressing the SEARCH PINPOINT touch pad bring the search coil back over the target area Note that as you approach the target the volu...

Страница 34: ...y level and or raising the coil so you can just barely hear the signal For very weak signals make sure you press the SEARCHlPINPOINT pad with the coil completely out of the target area You may also tr...

Страница 35: ...Keeping these four rules in mind follow these steps for accurate target identification 1 Once you ve located a target pinpoint its exact location as in the Pinpointing procedure see p 24 Since accurat...

Страница 36: ...r CZ 7a Pro Whichever method you choose remember that responsible treasure hunters take pride in their ability to leave soil and vegetation intact and undamaged Recovery Tools 1 A heavy duty blunt scr...

Страница 37: ...the object as you pass the search coil over it Another false signal response may be a one way or disappearing signal You ll sweep over the target and get a good signal but you ll get nothing on the re...

Страница 38: ...power lines or nearby detectors operating at one of the CZ 7a Pro search frequencies The best solution is to move away from the source of the interference You may also try one of the following Switch...

Страница 39: ...detectors often give false signals at the edges of the search pattern just as the coil stops and begins accelerating back toward the operator If this is a problem try one or more of the following Keep...

Страница 40: ...e as shown in the drawing below may give a single target response but may pinpoint several inches away from its true location Check around the inside edges of your hole If you still don t find it enla...

Страница 41: ...I D set the search coil down close to the target and then whip it rapidly across the target just once with what can best be described as a flick of the wrist If the target disappears it s probably a s...

Страница 42: ...ignals If you hear a good beep but can t repeat it when you ve pinpointed it in the Pinpoint mode or if it beeps in only one sweep direction it s probably a piece of trash something you ve notched out...

Страница 43: ...hole for a second signal and carefully search the immediate area by walking slowly around the hole two or three times overlapping your sweeps in an ever widening circle Always dig every suspicious so...

Страница 44: ...m the handle grip by holding the grip in one hand and sliding the control housing toward you 2 Remove the battery doors by gently lifting the two tabs at the end of the control housing 3 Remove the ba...

Страница 45: ...xtreme temperatures Don t leave it inside a closed car that s sitting in the sun Or even worse the trunk of a car 3 If you scrub the search coil on the ground you ll eventually wear through the bottom...

Страница 46: ...ting Search Coil Submersible Control Housing Splashproof11 Speaker Splashproof Visual Display Custom Liquid Crystal Display Batteries 2 9 volt Alkaline 12 transistor drop in Battery Life Alkaline 15 2...

Страница 47: ...certain types of false signals 10 The length and terms of the warranty will vary outside the U S Check with your distributor for detarts Fisher Research Laboratory does not warrant suitability to spec...

Страница 48: ...with a Limited Lifetime Warranty Warranty may vary outside the United States See your dealer for details S E R V I C E Fisher is committed to providing you our valued customer with superior service E...

Отзывы: