Section 4

 

 

Safety Tips and Maintenance

Safety Tips

1. Use independent power supply.
2. Check if the local power supply voltage is suitable for use.
3. Do not drag the power supply cable when unplugging.
4. Do not use non-specified power cable nor damage cable.
5. Service should only be performed by a qualified professional.
6. The power supply must be unplugged under the following situations:
    a. when the unit is moved
    b. when the electrical cabinet or the moving component is opened
    c. when the equipment is malfunctioning
    d. when the equipment is not in use

Maintenance

Clean Spill

a. This instrument uses a brushless DC motor. It is maintenance free and
    has a long service time, high quality, and low noise level.
b. Surface can be cleaned with a mild detergent and water.

Section 5

 

 

Troubleshooting

Error

No shaking of the tray

Loud noise

Other

Cause

Power disconnected

Switch off

Power adaptor failure

Over-weighted or
unbalanced load

Electrical
malfunction 

Mechanical
malfunction

Keep record for maintenance

Solution

Connect the power

Switch on

Replace power adaptor

Adjust the weight and
position of load,
decrease rotation speed

Contact Fisher Scientific
 

Contact Fisher Scientific
 

Load moving

Tray loose

Machine case loose

Fasten tray screws

Fasten machine case
screws

Cannot start machine,

LED display window

off

Fix load position

4

-

1

5

-

1

If accidental spillage of liquids caused by mishandling or contained break
-age occurs on the surface of the instrument, please shut down the
instrument and clean  up the liquid  immediately.
If the liquid  has already spilled into the unit, please cut off the power
supply first and immediately clean up the liquid at the surface of the
instrument. Then place the instrument in a ventilated and dry environment
for 24 hours before reuse. If the instrument is still not functioning after
drying for 24 hours, please contact the manufacturer.

Warning: 

Disassembling/Assembling without a qualified professional's

guidance may cause malfunctioning of the instrument.

Please refer to the following table to troubleshoot if any malfunction occurs. 
If the problem still exists, contact your local sales representative.

Fisher Scientific

Fisher Scientific

Multi Platform Shaker

Multi Platform Shaker

Содержание 88861021

Страница 1: ...Multi Platform Shaker Catalog Number 88861021 88861022 Instruction Manual...

Страница 2: ...s and maintenance must be performed by qualified service personnel Material in this manual is for information purposes only Fisher Scientific committed to a continuing program of product development a...

Страница 3: ...Cable House Control Panel Foot 4 Platform Sunken Screws M4 8 4 Multi Platform Shaker Multi Platform Shaker Figure 1 Inspect package and contents upon receipt of the instruments If the package is seve...

Страница 4: ...Orbit Diameter Speed Accuracy Display Mode Display Accuracy 50 to 450 rpm load weight 3 kg 50 to 300 rpm load weight 3 to 4 5 kg Time Timing Range Requirement Overall Dimensions Platform Dimensions P...

Страница 5: ...ely cut off power to the unit by disconnecting the power cord from the unit or unplug from the wall outlet Disconnect unit from the power supply prior to maintenance and service Any spills should be r...

Страница 6: ...he instrument or even cause damage if placing loads asymmetrically 2 4 Capacity and Speed Conical Flask Size ml Max Speed rpm With Flask Clamp With Sticky Pad 2 5 2 6 Section 2 Overview Section 2 Over...

Страница 7: ...starts flashing press arrow button to decrease the time to 00 00 and then release the button The time setting is finished after the number shown on the display window has flashed twice 2 Timer mode Pr...

Страница 8: ...f Lower 10 RPM than the set speed and no more than 70 of the set speed More than 10 RPM than the set speed and no more than 130 of the set speed Lower 10 RPM than the set speed and lower than 70 of th...

Страница 9: ...n of Test Tube Rack 1 Place the test tube rack holder at the corresponding position on the aluminum platform and fasten the 4 sunk screws 3 Insert test tubes Note To prevent splashing containers shoul...

Страница 10: ...wheels to fasten the flasks and tighten the fixed handle Installation of Universal Platform with Adjustable Bars 1 Fasten Universal Platform with Adjustable Bars onto the platform Note The rotation s...

Страница 11: ...Connect the power Switch on Replace power adaptor Adjust the weight and position of load decrease rotation speed Contact Fisher Scientific Contact Fisher Scientific Load moving Tray loose Machine cas...

Страница 12: ...0ml flask clamp 1000ml flask clamp 2000ml flask clamp 3000ml flask clamp 5000ml flask clamp 140 140 mm 58 46mm 66 43mm 59 38mm 85 55mm 130 77mm 105 59mm 168 91mm 231 120mm 194 109mm 125 122 5mm 100 92...

Страница 13: ...Spare Parts Fisher Scientific Fisher Scientific Multi Platform Shaker Multi Platform Shaker When used in laboratory conditions and according to these operation instructions and maintenance this produ...

Отзывы: