CONTROLS

Meter

The meter of the M-97 serves 
two  purposes  for  the  opera-
tion of the instrument.  When 
used in the battery test mode, 
the meter gives a visual indi-
cation of the battery strength.  
A reading between 80 – 100 
is desirable.  If the reading is 
below 80, search depth and 
accuracy  can  decrease.  
Please change the batteries, if 
necessary.  (Note:  The batteries must be inserted correctly for the M-97 to 
operate.  Match up the correct battery terminals with the markings on the 
inside of the battery holder.  Failure to do so will not damage the instrument, 
however, the instrument will not function).

When searching with the M-97, the meter gives a visual indication to any 
change occurring in the field of detection.  This is primarily due to the coil 
passing  over  or  near  a metal object, but  can   occur when the  ground 
mineral conditions change.

On/Off Ground Rejection Control

This control turns the M-97 on and off.  It is used to electronically balance the 
M-97 to compensate for the natural mineral content of the soil or ground 
surface.  When tuned properly, raising and lowering the search coil above 
the ground will not cause a change in the meter reading or audio tone. 

Mode Switch

This control is used to change the mode function of the Locator.

Battery Test

With the detector turned on, the Battery Test mode will indicate 
battery strength.  This is a no-load battery test.

Normal

This setting is used for the Turn On and Go mode.  The Normal 
Mode requires very little Ground Rejection adjustment.

High

This setting is used for increasing the sensitivity of the M-97,which also 
increases the depth searching capabilities of the instrument.

Retune Button

When this button is depressed, the instrument will rebalance itself to the 
instrument settings and prevailing ground conditions.

M-97 Control Panel 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание M-97

Страница 1: ...M 97 Operating Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...s a substitute for a Utility Line Tracer Fisher Research Laboratory manufactures a complete line of equipment for Line Tracing Pipe and Cable Tracing New to the M series is the ease with which the M 9...

Страница 3: ...rch coil rests be tween 6 to 12 inches in front of your feet Your arm should be straight and relaxed with your grip held loosely Tighten the locking nut compression nut at the bottom of the upper stem...

Страница 4: ...n Off Ground Rejection Control This control turns the M 97 on and off It is used to electronically balance the M 97 to compensate for the natural mineral content of the soil or ground surface When tun...

Страница 5: ...press and release the Retune Button Lower the coil close to the ground There should be little or no change in the tone of the detector If the M 97 changes tone when the coil is lowered to the ground...

Страница 6: ...ablish the edges of the target Another method that will give a visual outline is to purposely detune the M 97 Move the coil away from the target Slowly bring the search coil toward the target As the s...

Страница 7: ...At max sound 50 mA At Audio threshold 17 5 to 18 5 mA Search Coil Configuration Double D Weight with 8 inch search coil 3 3 lbs 1 5kg 11 inch search coil 3 9 lbs 1 8kg Dimensions 38 to 50 inches adjus...

Страница 8: ...isher Our instruments are durable dependable and locate deeper R E P U T A T I O N Fisher produced the first patented metal detector in 1931 For over 80 years the Fisher logo has been a mark of excell...

Отзывы: