Fisher & Paykel WH7560J1 Скачать руководство пользователя страница 16

479645 

16 

FAULT CODES 

Before replacing any components, always check the harness and connections. 

 

Fault Code  Short Description 

Reason 

door open  Door detected as not closed.  Door has been detected as not being 

closed  20  sec  after  program  has 
been started. 

no tap 

Expected water level not 
attained within 8 minutes. 

Target  water  level  has  not  been 
reached in the allowed time. 

E7:00 

Wash Motor Error. 

The  initial  speed  of  the  motor  has 
been detected as being out of sync.  

E7:01 

Motor Stall Error. 

The  motor  control  module  has  been 
unable to start the motor. 

E7:02 

Motor Loss of Phase. 

The  motor  control  module  has 
detected a loss of  a of the phase in 
the motor. 

E7:03 

Motor Over Current. 

The  motor  control  module  has 
detected excessive current. 

E7:04 

Motor Current Sense Error. 

Motor current sensing circuit is faulty. 

E7:06 

Motor Brown Out. 

The supply voltage level has become 
too  low  to  power  the  motor  control 
module.

 

E7:07 

Motor Winding Over Temp. 

Motor  control  module  has  detected 
the motor windings over temperature. 

E7:08 

Motor Bridge Over Temp. 

Motor  control  module  has  detected 
that  the  motor  bridge  electronics  is 
over temp  

E7:09 

M/C Module Self-Test Error.  Motor  control  module  during  its self-

test routine has detected an error. 

Err 10 

Heater NTC error which is 
displayed at end of program.  

The  heater  NTC  circuit  has 
malfunctioned. 

Err 12 

Water level has exceeded 
flood  protection level. 

Water  level  readings  found  to  be 
above the flood protection level. 

Err 37 

Pump error.  

The water level has not changed in 6 
minutes. 

Err 74 

Pressure sensor out of range.  Pressure  sensor  frequency  is  out  of 

range   

Содержание WH7560J1

Страница 1: ...479645 Service Diagnostics Front Load Washer Models WH8560P1 WH8560J1 WH8060P1 WH7560P1 WH7560J1...

Страница 2: ...3 1 7 Drain Pump 4 1 8 Wash Motor 4 1 9 Water Level Sensor 4 2 MODEL SIZE SETTING 5 3 DIAGNOSTIC MODE 6 3 1 Entering Diagnostic Mode 6 3 2 Self Test 7 3 3 Water Valve Tests 7 3 4 Drum Rotation Test 8...

Страница 3: ...560J1 7 5Kgs 1 3 Door Lock Type Solenoid Activated With mechanical release Resistance Terminal 2 3 190 10 Nominal Voltage Terminal 2 3 230V 1 4 Heating Element Resistance 30 25 C Nominal Voltage 230V...

Страница 4: ...tal power 30W Resistance 210 10 Pump out rate 17litres min 1 8 Wash Motor Electronically commutated direct drive 3 Phase brushless DC motor Motor resistance Aluminium Stator Per Winding Phase to Phase...

Страница 5: ...5 seconds NB After 3seconds the machine will beep Continue holding both buttons for 2 more seconds and the machine will then display the model size in the screen 1485 WH8560P 1400RPM 8 5Kgs 1185 WH856...

Страница 6: ...mode the following I O s can be operated I O Select Then Press Toggle Hot Valve Cold Valve 1 Cold Valve 2 Everyday Cycle Wash Temp Button Spin Button Options Button Rotate Motor Clockwise Motor Count...

Страница 7: ...and cold valve 1 Cold Valve 2 Softener turn on and will keep filling until the water level is correct for the heater test 66 66 is displayed and the heater turns on for 10 seconds 55 55 appears on the...

Страница 8: ...k LOCI will be displayed for 2 seconds to indicate the lock action and the door should be locked To deactivate press the WASH TEMP button again OPEN will be displayed for 2 seconds to indicate the unl...

Страница 9: ...d the information that corresponds to level d09 is displayed in the 7segment display 1 second later shows 250 RPM Level Diagnostic info Displayed Level Diagnostic info Displayed d 00 Last User Warning...

Страница 10: ...wash cycle position of the last user warning Output Displayed on Screen Cycle Position 01 Agitation 02 Rinse 03 Spin d 03 Fault Code of Last Fault The fault data will relate to a fault code as detail...

Страница 11: ...on 02 Rinse 03 Spin d 06 Current Temperature Degrees C The temperature at the NTC Thermistor in O C d 07 Target Temperature The actual target temperature the machine is to obtain d 08 Cycle count The...

Страница 12: ...ual speed of the drum displayed in Rev s Per Minute Once the machine has exceeded 999 RPM the display output becomes alpha numeric Letter RPM A000 1000 B000 1100 C000 1200 D000 1300 E000 1400 E g for...

Страница 13: ...ich decreases as the water level increases d 12 Target Fill Level The target water level displayed as a frequency d 13 Display Software Version Display software version number d 14 Motor Control Modul...

Страница 14: ...functions can be demonstrated In this mode the machine cannot be started To select demonstration mode 1 Turn the machine on at the mains supply and on at the console 2 Press and hold the KEYLOCK OPTIO...

Страница 15: ...ignals user warnings by displaying a warning in plain text Where multiple words are displayed one word at a time with 1 second pause between changing from one word to the other along with a rippling s...

Страница 16: ...l module has detected excessive current E7 04 Motor Current Sense Error Motor current sensing circuit is faulty E7 06 Motor Brown Out The supply voltage level has become too low to power the motor con...

Страница 17: ...ature Err 105 Comms Error There is a communications error between the display and motor control module Err 235 Door Locked Door lock not activating when instructed out of bal Out of Balance load Redis...

Страница 18: ...479645 18 7 CONNECTOR LAYOUT Display Module Door Lock Motor Control Module P 3 2 1 3 1 CN2 CN1 1 3 6 CN8 1 4 CN3 1 3 6 CN14 1 4 P171 P101 P 3 2 4...

Страница 19: ...N14 3 to CN14 4 13 K Motor Stator P171 1to P171 2 28 P171 2 to P171 3 28 P171 1 to P171 3 28 Drain Pump CN1 5 to CN1 2 212 Door Lock Pin 2 3 or CN1 1 to CN2 1 190 Water valve hot CN1 2 to CN3 4 4 K Pr...

Отзывы: