Страница 1: ...INSTALLATION GUIDE WH8060J WH8060P WH8560P WH9060J WH9060P WH1060P3 and WM1490P models FRONT LOADER WASHING MACHINE NZ AU SG BI EU ...

Страница 2: ......

Страница 3: ... accessibility to the plug or incorporate a switch in the fixed wiring in accordance with the wiring rules to allow disconnection of the appliance from the supply after installation Water supply requirements z Inlet water pressure Max 1MPa 145psi Min 30kPa 4 5psi z Inlet water flow rate Min 6 litres minute z A pressure reducing valve must be installed if pressure is higher than 1MPa z For optimum ...

Страница 4: ... z Min z Max 850 865 B Overall width 600 C Overall depth 655 D Depth with door open 1075 Exact height is dependent on foot adjustment Including dial and door when closed Actual product dimensions may vary by 2mm WH8060P WH8560P WH9060J WH9060P WH1060P3 WM1490P models A B C D D C ...

Страница 5: ...the product z In cupboard 650 695 b b b b Front panel of the product CLEARANCE DIMENSIONS MM A Minimum washer door clearance to adjacent wall 320 B Minimum gap clearance to adjacent product or cabinetry 20 Applies to sides top and rear Actual dimensions may vary by 2mm For paired installation dimensions please visit fisherpaykel com WH8060P WH8560P WH9060J WH9060P WH1060P3 WM1490P models ...

Страница 6: ...IONS MM A Overall height z Min z Max 850 865 B Overall width 600 C Overall depth 595 D Depth with door open 1015 Exact height is dependent on foot adjustment Including dial and door when closed Actual product dimensions may vary by 2mm D C A B C D WH8060J ...

Страница 7: ...pth z Flush with front panel of the product z In cupboard 580 635 b b b b Front panel of the product CLEARANCE DIMENSIONS MM A Minimum washer door clearance to adjacent wall 320 B Minimum gap clearance to adjacent product or cabinetry 20 Applies to sides top and rear Actual dimensions may vary by 2mm For paired installation dimensions please visit fisherpaykel com ...

Страница 8: ... Pressure max 1 MPa 150psi min 30 kPa 4 5psi Flow rate at tap Min 6 litres minute Cold water temp max 35 C Hot water temp max 65 C 1500 or 1600mm model dependant 1500mm 1500mm 600mm min 1000mm max Drain Hose Power Cord Water Hoses DRAINAGE HEIGHTS CONNECTION LOCATIONS LENGTHS Recommended standpipe height is 800mm ...

Страница 9: ...5 Turn the tap s on and check for leaks Check for leaks again after 24 hours Water supply requirements If you have an uncontrolled water heating source eg a wet back or solar heating system you should fit a tempering valve This will ensure the hot water temperature remains within safe limits Contact your registered plumber to select and install the tempering valve Your cold water should not exceed...

Страница 10: ...se guide is used to hold the drain hose over the tub or standpipe 1 Flex the guide apart and pull the hose through the guide 2 Secure the hose guide to a wall or the back wall of the cupboard using a screw 3 Drill out the blanking insert from spigot to ensure the washer can drain correctly 4 Attach drain hose to spigot and secure using a hose clamp 5 Check for leaks z The clothes washer is fitted ...

Страница 11: ...clearances Recheck the washer is level front to back and side to side Repeat the above steps if required It is IMPORTANT to level the washer Having a level washer set up in its cavity will ensure best performance for spinning minimising noise vibrations and wear and tear on the washer LEVELLING THE WASHER COMPLETE INSTALLATION z Turn on the water and check all hose connections for leaks Make sure ...

Страница 12: ... displayed on the screen refer your user guide 5 6 INSTALLER CHECKLIST TO BE COMPLETED BY THE INSTALLER Have the packaging and transit bolts and rods been removed Is the washer correctly levelled feet are extended and cabinet corners are clear of the floor Is the drain hose threaded through the hose guide U bend with no more than 20mm extended and hooked into your standpipe or tub or attached to a...

Страница 13: ...13 SPARE PARTS PART NO Hose s inlet long 2 m 422680P Hose s inlet large bore 426123P Available from your Fisher Paykel dealer or a Fisher Paykel trained and supported service technician SPARE PARTS ...

Страница 14: ......

Страница 15: ......

Страница 16: ...nge at any time The product specifications in this guide apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time For current details about model and specification availability in your country please go to our website or contact your local Fisher Paykel dealer ...